background image

9

EN

the wind level is shown by a series of icons:

ICoN

LEVEL

dESCRIPtIoN

N/A

<2 miles/h (<4km/h)

Light

2-8 miles/h (3-3 km/h)

Moderate

9-25 miles/h (4-4 km/h)

Strong

26-54 miles/h (42-87 km/h)

Storm

>55 miles/h  (>88 km/h)

to  view  the  maximum  wind  speed  and  minimum 
wind chill readings:

.  Press 

SELECt

  to  navigate  to  the  Wind  Speed  /  Wind 

Direction / Wind Chill Area.    will show next to the Area.

2.  Press 

MAX  /  MIN 

to  toggle  between  current  /

 

MAX 

wind speed and current / MIN

 

wind chill

 

displays.

The  timestamp  of  when  maximum  wind  speed  was 
recorded is displayed accordingly in the Clock Area.

to clear minimum wind chill reading / maximum wind 
speed reading:

.  Press 

SELECt

  to  navigate  to  the  Wind  Speed  /  Wind 

Direction / Wind Chill Area.   will show next to the Area.

2.  Press 

MAX

  / 

MIN

  repeatedly  until  minimum  wind  chill 

reading or maximum wind speed reading is displayed.  

3.  Press and hold 

MAX /

 

MIN 

to clear the readings.

 NotE 

 The wind chill factor is based on the combined 

effects of temperature and wind speed. Displayed wind 
chill is calculated solely from Channel  sensor.

UVI / BARoMEtER / RAINFALL

The  weather  station  works  with  one  UV  sensor  and 
one  rain  gauge.  The  station  is  capable  of  storing  and 
displaying  the  hourly  history  data  for  the  last  0  hours 
of  UV  index,  and  24

 

hours  of  rainfall  and  barometric 

pressure readings. 

UVI

BARoMEtER

RAINFALL

The  bar  chart  display  shows  the  current  and  historical 
data for the UV index, barometric pressure and rainfall 
readings.

  NotE 

  The  number  shown  in  the  horizontal  axis  (Hr) 

indicates how long ago each measurement was taken (e.g. 
3  hours  ago,  6  hours  ago,  etc.).  The  bar  represents  the 

measurement taken for that specific 1 hour period.  E.g., if it 

is 0:30 pm now, the bar plotted directly above - shows the 
reading recorded from 9 to 0 pm and -6 shows the reading 
recorded earlier in the evening, between 4pm-5pm.

to view the UV / Barometer / Rainfall readings:

.  Press 

SELECt

 to navigate to the UV / Barometer / 

Rainfall Area.   will show next to the Area.

2.  Press 

ModE

  to  toggle  between  UVI  /  Barometer  / 

Rainfall readings. The corresponding icon will appear:

UVI

BARoMEtER

RAINFALL

to select the measurement unit for the barometer or 
rainfall readings:

In  the  UV  /  Barometer  /  Rainfall  Area,  press 

UNIt

  to 

switch between:

•  Barometer: Millimeters of mercury (

mmHg

), inches of 

mercury (

inHg

), millibars per hectopascal (

mb

).

•  Rainfall:  Millimeters  (

mm

),  inches  (

in

),  recorded  for 

that hour.

 NotE 

  As the purpose of the bar graph is only to provide 

a quick comparison between the records of the past 24 

hours,  the  vertical  axis  cannot  convert  from  inches  to 
mm.    Therefore,  changing  the  measurement  unit  will 
have no effect on the bar graph display.

UV INdEX

the UV index levels are as follows:

UV INdEX

dANGER LEVEL

ICoN

0-2

Low

3-5

Moderate

6-7

High

8-0

Very high

 and above

Extremely high

to view the maximum UV reading:

.  Press 

SELECt

 to navigate to the UVI / Barometer / 

Rainfall Area.    will show next to the Area.

2.  Press 

ModE

 repeatedly to select UV display.

3.  Press 

MAX  /  MIN 

to  toggle  between  current  /

 

MAX 

UV index display.

The timestamp of when maximum UV was recorded is 
displayed accordingly in the Clock Area.

to clear maximum UV reading:

.  Press 

SELECt

 to navigate to the UVI / Barometer / 

Rainfall Area.    will show next to the Area.

2.  Press 

ModE

 repeatedly to select UV display.

3.  Press and hold 

MAX

 / 

MIN

 to clear the readings.

BARoMEtER

to  set  the  altitude  level  compensation  for  the 
Barometer readings:

.  Press 

SELECt

 to navigate to the UVI / Barometer / 

Rainfall Area.    will show next to the Area.

2.  Press 

ModE

  repeatedly  to  select  Barometric 

display.

3.  Press and hold 

ModE

 to enter the altitude setting.

4.  Press 

UP

 / 

doWN 

to increase / decrease the setting 

value. 

5.  Press

 ModE

 to confirm the setting.

WMR180_UM_EN_R7.indd   9

2011/5/30   3:57:35 PM

Содержание WMR180A

Страница 1: ...VI Barometer Rainfall 9 UV Index 9 Barometer 9 Rainfall 10 Backlight 10 Reset 10 Specifications 10 Precautions 11 About Oregon Scientific 11 EU declaration of conformity 11 FCC statement 11 Introducti...

Страница 2: ...LIGHT 1 2 3 4 5 6 E U UK 1 2 3 4 5 6 1 2 3 A 4 B C D 1 2 7 8 9 3 6 5 4 10 11 WMR180_UM_EN_R7 indd 2 2011 5 30 3 56 30 PM...

Страница 3: ...UVI level indicator 6 Maximum UV is displayed 7 UVI barometric pressure rainfall historical bar chart display D Clock Calendar Moon Phase Area 1 3 6 4 5 2 1 AM PM 2 Time zone offset 3 Timestamp is di...

Страница 4: ...ditY sensor 1 2 3 1 Holding sensor twist and click to the left 2 Pull sensor away from casing 3 Insert batteries matching the polarities Press RESET after each battery change 5 4 4 Insert sensor into...

Страница 5: ...Wind direction indicator Move the direction of the wind indication and verify the icon moves in the same direction Temperature humidity sensor 1 Press SELECT until the selected area icon is in the bot...

Страница 6: ...re solar panel at desired angle 10 Remove outdoor sensor from casing Plug one solar panel cable into the socket Replace sensor into the casing NOTE For best results direct solar panel as follows Solar...

Страница 7: ...hold MODE to change the clock setting The setting will blink 3 Press UP DOWN to increase decrease the setting value 4 Press MODE to confirm 5 Repeat steps 3 to 4 to set the time zone offset hour 23 ho...

Страница 8: ...ory To select the temperature measurement unit Press UNIT to select C F NOTE The unit of all temperature related displays will be changed simultaneously To view temperature Current Max Min temperature...

Страница 9: ...m and 6 shows the reading recorded earlier in the evening between 4pm 5pm To view the UV Barometer Rainfall readings 1 Press SELECT to navigate to the UV Barometer Rainfall Area will show next to the...

Страница 10: ...90 Accuracy 25 40 7 40 80 5 80 90 7 Memory Current Min and Max Radio controlled Atomic clock Synchronization Auto or disabled Clock display HH MM SS Hour format 12hr AM PM or 24hr Calendar DD MM or M...

Страница 11: ...entific Customer Service COUNTRIES RTTE APPROVED COMPLIED All EU countries Switzerland CH and Norway N FCC statement This device complies with Part 15 of the FCC Rules Operation is subject to the foll...

Отзывы: