Oregon Scientific RMS 300 Скачать руководство пользователя страница 3

E

N

3

1

.  MODE: 

Toggle  between  clock  displays;  enter  setting 

mode

2

 : 

Increase values in setting mode; activate clock 

signal reception

3

.  RESET: 

Reset unit to default settings

4

USB port (at the side)

5

Battery compartment (at the bottom)

6

.  MEM:

Toggle  between  maximum  and  minimum 

temperature / humidity displays

7

Decrease  values  in  setting  mode;  deactivate 

clock signal reception

8

.  °C / °F: 

Select temperature unit

9

.  EU  /  UK: 

Select  the  nearest  radio  signal  (RMS300 

only)

REMOTE SENSOR (FIG 3)

1

2

3

4
5

1.  LED status indicator
2.  Wall mount hole
3.  Battery compartment
4. 

RESET

 hole

5. 

CHANNEL

 switch

GETTING STARTED

INSERT BATTERIES

1.  Remove the battery compartment.
2.  Insert  the  batteries,  matching  the  polarities  (see  FIG 

2).

3.  Press 

RESET

 after each battery change.

  

 LOCATION

MEANING

Clock / alarm area

Main unit batteries low

Outdoor temperature area

Remote sensor batteries low

REMOTE SENSOR 

The remote sensor can collect data from up to 3 channels.

To set up the remote sensor:

1.  Open  the  battery  compartment  and  insert  batteries, 

matching the polarity.

2.  Select a channel then press 

RESET

3.  Close the battery door.
4.  Place  the  remote  sensor  within  30  m  (98  ft)  from  the 

main unit.

RMS300 IM EN R3.indd   3

1/4/08   11:52:32 AM

Содержание RMS 300

Страница 1: ...ert Batteries 3 Remote Sensor 3 Sensor Data Transmission 4 Clock 4 Clock Reception 4 Manually Set Clock 4 Temperature And Humidity 5 Ice Alert Channel 1 Only 5 Connection to PC 5 Backlight 6 Reset 6 S...

Страница 2: ...e 4 Outdoor humidity 5 Indoor temperature and humidity 6 Clock signal reception indicator 7 Main unit battery indicator 8 Clock calendar display 9 USB status indicator 10 Time zone RMS300A only 11 Ice...

Страница 3: ...dicator 2 Wall mount hole 3 Battery compartment 4 RESET hole 5 CHANNEL switch GETTING STARTED INSERT BATTERIES 1 Remove the battery compartment 2 Insert the batteries matching the polarities see FIG 2...

Страница 4: ...o synchronize its clock automatically with a clock signal RMS300 Slide EU UK to select the signal received EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany UK MSF 60 signal within 1500 k...

Страница 5: ...F To auto scan channels Press and hold MEM to display each channel s recorded data in sequence for 3 seconds To select channel press To toggle between current minimum and maximum temperature humidity...

Страница 6: ...idity range 25 95 Humidity resolution 1 Power 2 x UM 3 AA 1 5 V batteries REMOTE UNIT THGN132N L x W x H 50 x 22 x 96 mm 1 9 x 0 9 x 3 8 in Weight 62 g 2 2 ounces without battery Signal frequency 433...

Страница 7: ...c products If you re in the US and would like to contact our Customer Care department directly please visit www2 oregonscienti c com service support OR Call 1 800 853 8883 For international inquiries...

Страница 8: ...ceiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORM...

Отзывы: