background image

1

MULTI-CHANNEL IN-OUT

CABLE FREE

THERMO-HYGROMETER

MODEL :  EMR963HG

USER’S  MANUAL

INTRODUCTION

Congratulations on your purchase of Oregen Scientific's Cable-Free
Thermo-Hygro sensor.

Enclosed with this package is one (1) main display unit and one (1)
cable-free remote thermo-hygro sensor unit.

The main unit has an extra-large multifunction 2-line LCD that
shows recordings for indoor and outdoor temperatures, humidity,
maximum and minimum recordings and trend indicators. The unit
supports up to three 433MHz remote thermo-sensors or thermo-
hygro sensors. A variety of additional sensors can be purchased
separately.

In addition to monitoring maximum and minimum temperature and
humidity readings, the unit also has an alarm that can be set to
activate once readings exceed a given variance.

No wire installation is required between the main and remote units.
As the EMR963HG operates at 433MHz, it can be used in the U.S.
and most places in Continental Europe.

FEATURES: MAIN UNIT

Содержание EMR963HG

Страница 1: ...outdoor temperatures humidity maximum and minimum recordings and trend indicators The unit supports up to three 433MHz remote thermo sensors or thermo hygro sensors A variety of additional sensors can...

Страница 2: ...e upper or lower temperature and humidity of individual channels G AL ON OFF button Activates or deactivates alarm H RESET Returns all settings to default values and erases all memories I C F slide sw...

Страница 3: ...t to the remote unit reset the main unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Positiontheremoteunitandmainunitwithinef...

Страница 4: ...Note that once a channel is assigned to a remote unit you can only change it by removing the batteries or resetting the unit BATTERY INSTALLATION MAIN UNIT The main unit uses two 2 UM 3 or AA size alk...

Страница 5: ...CHECK REMOTE AND INDOORS TEMPERATURES Display of readings from a remote sensor or the main unit is a one step procedure The remote sensor channel or the main unit display is indicated in a box under t...

Страница 6: ...the temperature goes above or below the temperature measuring range of the main unit or the remote unit stated in specification the display will show HHH or LLL REMOTE SENSOR SCANNING The unit can be...

Страница 7: ...are recorded HOW TO USE CHANNEL 1 TEMPERATURE HUMIDITY ALARM Upper and lower temperature and humidity limits for channel 1 can be set so that an alarm activates when the limits are exceeded The high...

Страница 8: ...a 1 minute Press any key to momentarily stop the alarm The alarm will activate again if the limit continues exceeds the set limit Note If a second limit is passed while an alarm is active the first a...

Страница 9: ...switch of the main unit Whatever the display units of the remote sensors are they will be automatically converted to the chosen one of the main unit LOW BATTERY WARNING When it is time to replace bat...

Страница 10: ...lcomponents Doingsowill invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts 5 Only use fresh batteries as specified in the user s manual Do...

Страница 11: ...with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation...

Страница 12: ...f the manufacturer WARRANTY This product is warranted to be free of defects in manufacturing for 90 days after purchase For technical support please call 800 853 8883 Monday Friday 8am 5pm PST Defecti...

Отзывы: