Oregon Scientific BAR938HGA Скачать руководство пользователя страница 4

GB

4

NOTE ON °C AND °F

The outdoor temperature display on the main unit is dominated by
the selection on the °C/°F slide switch of the main unit. Whatever
the display unit of the remote sensor is, it will only apply to the
remote sensor. The temperature display on the main unit will be
automatically converted to the chosen one on the main unit.

MAXIMUM AND MINIMUM

TEMPERATURES & HUMIDITY

The maximum and minimum recorded temperatures and humidity
will be automatically stored in memory. To display them, press
MEMORY to toggle among the maximum, minimum and current
temperatures and humidity. The respective MAX or MIN indicator
will be displayed.

To clear the memory, hold down MEMORY for three seconds. The
maximum and minimum temperatures and humidity will be erased.
If you press MEMORY now, the maximum and minimum
temperatures and humidities will have the same values as the
current one until different readings are recorded.

TEMPERATURE AND HUMIDITY TREND

The temperature trend and humidity trend indicators show the
trend of collected readings. Three trends  rising, steady and falling,
will be shown.

WEATHER FORECAST

BAR938HGA is capable of detecting barometric pressure changes,
and based on the data collected, can predict the weather for the
next 12 to 24 hours. The effective range covers an area of  18 to 30
miles.

sunny

partly cloudy

cloudy

rainy

snowy

HOW TO SET AND ACTIVATE

THE DAILY ALARM

When the daily alarm time is displayed, press and hold ALARM for
three seconds.

Enter the value for the hour digits by the UP or DOWN button.
Press ALARM to confirm and go to the minute digits. Enter the
value and press ALARM to confirm.

The alarm is automatically activated and 

 ] will be displayed.

To deactivate it, press ALARM once in the alarm display mode.

When the alarm is active, it will go off at the set time. The display
will light up for five seconds with the 

 ] icon flashing. Without

interruption, the alarm will go off for 1 minute.

To stop the alarm, press [ALARM], [MODE], [LIGHT], [ 

 ],

[   ] or [ZONE] button.

HOW TO CHECK INDOOR AND OUTDOOR-

REMOTE TEMPERATURES & HUMIDITIES

To display indoor temperatures and humidities, press the
CHANNEL button until the [ 

 ] indicator lights up.

To display outdoor-remote temperatures and humidities, press the
CHANNEL  button to scroll through the readings from up to 3
remote sensors.

The temperature can be shown in Centigrade (°C) or Fahrenheit
(°F). The unit is selected on the °C / °F slide switch.

If the readings go above or below the specified range, the display
will show flashing “HHH” or “LLL”.

CHANNEL SCAN FUNCTION

Press and hold CHANNEL button for 3 seconds to enter channel
scan function. The readings of each channel will be displayed
automatically, one by one, for 4 seconds. Press CHANNEL again to
stop the scan function.

NOTE ON REMOTE TEMPERATURE

& HUMIDITY

Once batteries are in place for the remote unit, it will start transmit-
ting samplings at 39-43-second intervals.

If no signals are received when the remote  temperature and
humidity is selected, blanks will be displayed. Press and hold the
CHANNEL and MEMORY buttons together to enforce a search.
This is useful in synchronizing the transmission and reception of
the remote and main units.

If that fails, check if the remote unit is still in place. Make sure the
transmission is within range and path is clear of obstacles and
interference.

Repeat this procedure whenever you find discrepancies between
the reading shown on the main unit and the remote unit.

Arrow

indicator

Temperature

Trend

Steady

Falling

Rising

Arrow

indicator

Humidity

Trend

Steady

Falling

Rising

Содержание BAR938HGA

Страница 1: ...will show the pressure trend of the last 24 hours Whatismore BAR938HGAisequippedwithamoonphasescanner which lets you check the moon phase of any day between 1990 and 2019 Other features include a HiG...

Страница 2: ...values A A BATTERYCOMPARTMENT Accommodates four UM3 or AA size batteries AB TABLE AND CONTROL STAND Acts as control panel and supports the unit when lying flat A C LOCK SLIDE BUTTON Slide to the righ...

Страница 3: ...display press MODE ABOUT RADIO RECEPTION BAR938HGA is designed to automatically synchronize its calendar clock once it is brought within range of the U S Atomic Clock radio signal It will scan and adj...

Страница 4: ...ated and will be displayed To deactivate it press ALARM once in the alarm display mode When the alarm is active it will go off at the set time The display will light up for five seconds with the icon...

Страница 5: ...want to check the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the button will go back by an hour The recorded barometric changes for the pas...

Страница 6: ...n a flat surface Then adjust the angle of the display panel for best display and support HOW TO RESET THE UNIT The RESET button allows you to return all settings to factory set values The button is re...

Страница 7: ...ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving unit Increase the separation between the equipment...

Отзывы: