Oregon Scientific BAR913HG Скачать руководство пользователя страница 11

11

GB

HOW TO RESET THE UNIT

The RESET slot allows you to return all settings to factory values.
Accessing the slot is required only when the unit is not operating
in a favorable way such as in the rare case of a malfunction.

The RESET slot is located inside the battery compartment door. To
use the button,

1.  Lift open the battery compartment door.

2.  Place a blunt stylus into the slot and press.

3.  Replace the battery compartment door.

MAINTENANCE

When handled properly, this unit is engineered to give you years
of satisfactory service. Here are a few product care instructions:

1. Do not immerse the unit in water. If the unit comes in contact

with water, dry it immediately with a soft lint-free cloth.

2. Do not clean the unit with abrasive or corrosive materials.

Abrasive cleaning agents may scratch the plastic parts and
corrode the electronic circuit.

3. Do not subject the unit to excessive: force, shock, dust,

temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged batteries, or
distorted parts.

4. Do not tamper with the unit’s internal components. Doing so

will terminate the unit’s warranty and may cause damage. The
unit contains no user-serviceable parts.

5. Only use new batteries as specified in this instruction manual.

Do not mix new and old batteries as the old batteries may leak.

6. Read this instruction manual thoroughly before operating the unit.

SPECIFICATIONS

Temperature Measurement

Main unit

Indoor Temperature measurement

Proposed  operating  range

: -5.0°C  to +50.0°C

(23.0°F  to 122.0°F)

Temperature  resolution

: 0.1°C  (0.2°F)

Relative Humidity measurement

Measuring  Range

: 25% RH to 95% RH

at 25°C (77°F)

Resolution

: 1% RH

Remote unit

Temperature measurement

Proposed operating  range

: -20.0°C to +60.0°C

(-4.0°F to 140.0°F)

Temperature resolution

: 0.1°C (0.2°F)

RF Transmission Frequency

: 433 MHz

No. of Remote unit

: Up to 3 units

RF Transmission Range

: 30 meters

Temperature sensing cycle

: around 40 seconds

913hg-e.p65

07/12/2001, 3:06 PM

11

Содержание BAR913HG

Страница 1: ... receive and display readings from up to 3 remote sensors As part of the weather forecasting function the unit has a built in barometer that displays atmospheric pressure Using kinetic movement graphic illustrations the unit displays atmospheric pressure trends and displays forecasts as sunny partly cloudy cloudy rainy and snowy The BAR913HG is also a Radio Frequency RF controlled clock It can aut...

Страница 2: ...ing A5 TIME DATE ALARM WINDOW Displays the current time date day month and year daily alarm or Pre alarm function Radio Frequency RF status indicator B CONTROL BUTTONS B1 CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL BUTTON Displays the temperature and humidity readings of the indoor or remote sensor B2 MEMORY MEMORY MEMORY MEMORY MEMORY BUTTON Displays minimum and maximum temperature and humidity readi...

Страница 3: ...ween mb hPa or inHg pressure unit display C3 RESET SLOT Resets the unit by returning all setting to their default values C4 C F SLIDE SWITCH SelectsbetweenCentigrade C orFahrenheit F temperature unit display C5 RETRACTABLE TABLE STAND Easy open table stand with lock FEATURES REMOTE THERMO HYGRO SENSOR 913hg e p65 07 12 2001 3 06 PM 3 ...

Страница 4: ...t first Then proceed with inserting the batteries for the main unit 2 Position the remote unit and the main unit within effective transmission range In usual circumstances the effective range is 30 meters 3 Though the remote unit is weather proof it should be placed away form direct sunlight rain or snow BATTERY INSTALLATION MAIN UNIT 1 Gently lift the tab on the battery compartment door 2 Insert ...

Страница 5: ...in range of the Frankfurt DCF77 radio signal When the BAR913HG is within range its radio control mechanism will override all manual settings When the unit is receiving radio signal the RADIO RECEPTION signal will start to blink A complete reception generally takes about two to 10 minutes depending on the strength of the radio signal When the reception is complete the RADIO RECEPTION signal will st...

Страница 6: ...Holding down either the up or down position will increase or decrease the value rapidly Press MODE again the minute will flash Again use the UP or DOWN button to change the minutes Note When changes are made to the this setting the seconds will start from zero Press MODE again the calendar settings are displayed and the year is flashing Use the UP or DOWN button to change the year Press MODE again...

Страница 7: ...icated by the appearance of the symbol To disable this function press the DOWN button in the Pre Alarm mode The symbol will disappear and will appear to indicate disable of this function The pre alarm will operate during the selected time interval before the daily alarm time For example if the daily alarm is set to go off at 7 00 am and the pre alarm operating time interval is set to 45 minutes th...

Страница 8: ... slide switch of the main unit Whatever the display unit of the remote sensor is it will only apply to the remote sensor itself and the temperature will be automatically converted to the chosen one of the main unit MAXIMUM AND MINIMUM TEMPERATURES HUMIDITIES The maximum and minimum recorded temperatures and humidities will be automatically stored in memory To display them press MEMORY Press MEMORY...

Страница 9: ...lies to night time implies clear weather COMFORT LEVEL INDICATORS ThecomfortlevelindicatorsCOMFORT WETorDRYwilltellyou if the curent environment is comfortable too wet or too dry The comfort indicator will appear on the display when the following conditions are satisfied Indicator displays on the unit Temperature Range 20 C to 25 C 68 F to 77 F 5 C 50 C 23 F 122 F 5 C 50 C 23 F 122 F Humidity Rang...

Страница 10: ...urs press the HISTORY button Each press on the button will go back by an hour Holding down the button will increase the value rapidly LOW BATTERY INDICATION When it is time to replace batteries the respective low battery indicator will show up when the corresponding channel is selected The battery level of the main unit is shown on the Weather Forecast Window when it is running low HOW TO WALL MOU...

Страница 11: ...sive force shock dust temperature or humidity Such treatment may result in malfunction a shorter electronic life span damaged batteries or distorted parts 4 Do not tamper with the unit s internal components Doing so will terminate the unit s warranty and may cause damage The unit contains no user serviceable parts 5 Only use new batteries as specified in this instruction manual Do not mix new and ...

Страница 12: ...r compliance could void the user s authority to operate the equipment R TTEComplianceNote This device complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directive if used for its intended use and that the following standard s has been applied Electromagnetic compatibility Article 3 1 b of the R TTE Directive Applied standards ETS 300 683 1997 Efficient use of the radio fr...

Страница 13: ...on Manual Mode D emploi Bedienungsanleitung Manuale di Istruzioni Instrucciones de Funcionamiento MODEL BAR913HG DIGITAL WEATHER FORECASTER WITH IN OUT THERMO HYGROMETER AND RF CLOCK 913hg e p65 07 12 2001 3 06 PM 13 ...

Страница 14: ...14 GB COUNTRIES RTTE APPROVAL COMPLIED Austria Belgium Denmark Finland France Germany Greece Italy Luxembourg Netherlands Portugal Spain Sweden UK and Ireland 913hg e p65 07 12 2001 3 06 PM 14 ...

Отзывы: