background image

EN

19

Barometer

Unit

mb / hPa or inHg

Resolution

1 mb (0.03 inHg)

Altitude

-100 to 2500 metres
(-328 to 8202 feet)

Display

Sunny (day / night),
partly cloudy (day /
night), cloudy, rainy,
snowy

Remote Unit (RTGR328N)

RF frequency

433 MHz

Range

Up to 100 metres (328 feet)
with no obstructions

Transmission

Approx. every 1 minute

Channel No.

1, 2, 3, 4 or 5

Unit

°

C or 

°

F

Radio-Controlled Clock

Synchronization

Auto or disabled

Clock display

HH:MM:SS

Hour format

12hr AM/PM (MSF format)
24hr (DCF format)

Calendar

DD / MM or MM / DD;
Day of the week in 1 of
5 languages (E, G, F, I, S)

Alarm

Daily & Pre-Alarm;
2-minute crescendo

Snooze

8-minute snooze

Power

Main Unit

Batteries

3 x UM-3 (AA) 1.5V

Thermo / Hygro Remote Unit

Batteries

2 x UM-3 (AA) 1.5V

It is recommended that you use alkaline

batteries with this product for longer performance.

NOTE

Содержание BAR816HG

Страница 1: ...t Daily Alarm 13 Set Pre Alarm 13 Activate Alarm 14 Snooze 14 Barometer 14 View Barometer Area 14 Select Measurement Unit 14 View Barometer History 14 Set Altitude 14 Weather Forecast 15 Weather Forec...

Страница 2: ...ool you can use from the convenience of your home In this box you will find Main unit Remote sensor RTGR328N Batteries The main unit is compatible with the following sensors THGR228N THGR328N THR228N...

Страница 3: ...5 Barometer Area Barometric pressure readings and trend lines 6 Clock Alarm Calendar Area Radio controlled clock alarms calendar 7 MODE Switch areas change settings display View alarm status set alar...

Страница 4: ...EN 4 1 2 3 4 5 6 7 BACK VIEW 1 Wall mount 2 Ventilation holes 3 Table stand 4 C F switch 5 RESET button 6 mb inHg switch 7 Battery compartment cover off...

Страница 5: ...EN 5 TABLE STAND AND WALL MOUNT To fix the table stand on to the base of the main unit To mount the unit on the wall Weather Forecast Area 1 Weather display 2 Low battery icon for main unit 1 2...

Страница 6: ...MIN humidity 9 Humidity 10 Comfort levels Barometer Area 1 Barometric pressure trend 2 Barometric pressure reading 3 Barometric pressure history e g 1 means barometric pressure value one hour ago 2 m...

Страница 7: ...7 1 2 3 1 4 5 6 7 2 3 REMOTE SENSOR RTGR328N 1 LCD display 2 LED status indicator 3 Ventilation duct 1 Signal reception 2 Channel number 3 Low battery icon 4 Time 5 Temp C or F 6 Humidity 7 Temp Humid...

Страница 8: ...supplied with this product Main unit 3 x UM 3 AA 1 5V Remote unit 2 x UM 3 AA 1 5V Insert batteries before first use matching the polarity as shown in the battery compartment For best results install...

Страница 9: ...Hygro Sensor The main unit can collect data from up to 5 Thermo Hygro Sensors The main unit is compatible with the following sensors THGR228N THGR328N THR228N THR328N THWR288 Additional sensors are s...

Страница 10: ...metallic or electronic objects Position the sensor close to the main unit during cold winter months as below freezing temperatures may affect battery performance and signal transmission The transmiss...

Страница 11: ...signals are collected by the remote sensor RTGR328N whenever it is within 1500 km 932 miles of a signal NOTE Initial reception takes 2 10 minutes and is initiated when you first set up the unit and w...

Страница 12: ...isabled the radio controlled clock or if you are too far from a RF signal NOTE 1 Press MODE to navigate to the Clock Area will show next to the Area 2 Press and hold MODE for 2 seconds 3 Select the ti...

Страница 13: ...minutes before the Daily Alarm It will sound whenever the recorded temperature from Channel 1 Sensor falls to 2 C 35 6 F or below For example if you set the alarm to 7 00 AM and the Pre Alarm to 45 m...

Страница 14: ...barometric pressure history measurements are recorded by the main indoor unit VIEW BAROMETER AREA Press MODE to navigate to the Barometer Area SELECT MEASUREMENT UNIT Slide the mb inHg switch in the...

Страница 15: ...When the Channel 1 sensor records a temperature of 2 C 35 6 F or lower the RAINY icon becomes SNOWY TEMPERATURE AND HUMIDITY The weather station can display the following information from any of the...

Страница 16: ...etween sensors press and hold CH for 2 seconds Each sensor s data will be displayed for 3 seconds To end auto scan press CH or MEM with the Temperature Humidity Area selected If you select a sensor th...

Страница 17: ...cloth and alcoholfree mild detergent Avoid dropping the product or placing it in a high traffic location WARNINGS This product is designed to give you years of service if handled properly Oregon Scie...

Страница 18: ...tdoor Range 20 C to 60 C 4 F to 140 F Resolution 0 1 C 0 2 F Memory Min Max Relative Humidity Range 25 to 95 Resolution 1 Memory Min max TROUBLESHOOTING PROBLEM SYMPTOM REMEDY Barometer Strange readin...

Страница 19: ...minute Channel No 1 2 3 4 or 5 Unit C or F Radio Controlled Clock Synchronization Auto or disabled Clock display HH MM SS Hour format 12hrAM PM MSF format 24hr DCF format Calendar DD MM or MM DD Day...

Страница 20: ...need on our website however if you re in the US and would like to contact the Oregon Scientific Customer Care department directly please visit www2 oregonscientific com service default asp OR Call 1 8...