background image

EN

6

Outdoor data is collected and displayed every 40 seconds.
Indoor data is collected and displayed every 10 seconds.

SELECT TEMPERATURE UNIT

Slide the 

°

C / 

°

F

 switch into the desired location. The

switch is located in the main unit battery compartment.
The setting for the main unit overrides the remote sensor
setting.

SELECT CHANNEL NUMBER

Press 

CHANNEL

 to switch between sensors 1-3.

The icon shows the selected sensor.

To auto-scan between sensors, press and hold

CHANNEL

 for 2 seconds. Each sensor’s data will be

displayed for 3 seconds. To end auto-scan, press

CHANNEL

 or 

MEM

.

NOTE

 If you use a sensor that collects only temperature

data, humidity will not be shown.

NOTE

 For more information on the sensor see “Remote

Sensor THGR122NX” section.

MINIMUM / MAXIMUM RECORDS

The 

MEM

 button is located in the main unit battery

compartment. Press 

MEM

 to toggle between current,

maximum (MAX) and minimum (MIN) records. To clear
the records, press and hold 

MEM

 for 2 seconds. A beep

will sound to confirm that the memory has been cleared.

MOON PHASE

The Calendar must be set for this feature to work, see
“Set Clock” section.

• Press   or   to view the moon phase for the next or

previous day.

• Press and hold   or   to scan quickly through the

years (2001 to 2099).

KINETIC-
WAVE
ICON
DESIG-

Indoor

Remote

Remote

Remote

NATED

Display

Display

Display

Display

DISPLAY

Channel 1 Channel 2 Channel 3

New Moon

Waxing Crescent

First Quarter

Waxing Gibbous

Full Moon

Waning Gibbous

Last Quarter

Waning Crescent

SWITCH CLOCK DISPLAY

Press 

MODE

 to toggle between Clock with Seconds and

Clock with Weekday display.

ALARM

This product is equipped with a 2-minute crescendo
alarm.

VIEW ALARM SETTINGS

Press        . The alarm time and alarm status will show in
the Clock Area.

SET ALARM

1. Press         to switch to alarm display.
2. Press and hold         again for 2 seconds. The alarm

settings will blink.

3. Select the hour and minute. Press   or   to change

settings. Press         to confirm.

ACTIVATE ALARM

Press      to activate or deactivate the alarm.      shows in
the Clock / Alarm Area when the alarm is activated.

SILENCE ALARM

When the alarm time is reached, the crescendo alarm
will sound for 2 minutes. To silence the alarm:

• Press 

SNOOZE

 to silence it for 8 minutes.

OR
• Press any key except 

SNOOZE

 to mute the alarm and

activate it again after 24 hours.

If no button is pressed, the alarm will automatically
silence after 2 minutes. It will then sound again after 8
minutes.

WEATHER FORECAST

This product forecasts the next 12 to 24 hours of weather
within a 30-50 km (19-31 mile) radius with 70 to 75
percent accuracy. The weather forecast is always
displayed.

SUNNY

PARTLY

CLOUDY

RAINY

CLOUDY

TEMPERATURE AND HUMIDITY

This product can display current, minimum, and maximum
temperature and humidity percentage information
collected by the remote sensors and main (indoor) unit.

BAR638HG_M_EN_6.p65

2005.4.27, 10:56 PM

6

Содержание BAR638HG

Страница 1: ...GR122NX 7 Clock 8 Power 8 About Oregon Scientific 8 EC Declaration of Conformity 8 Wireless Weather Station Model BAR638HG BAR638HG 2 BAR638HGU BAR638HGU 2 USER MANUAL INTRODUCTION Thank you for selecting the Oregon ScientificTM Wireless Weather Station BAR638HG BAR638HG 2 BAR638HGU BAR638HGU 2 This device bundles precise time keeping weather forecast and indoor and outdoor temperature and humidit...

Страница 2: ...VIEW 1 RESET hole 2 MEM View current maximum and minimum temperature and humidity readings 3 Battery compartment cover off 4 C F switch 5 MODE Change display settings 6 Increase setting activate RF clock 7 Decrease setting deactivate RF clock 8 CHANNEL Switch remote sensor 9 View alarm status set alarm 10 Press to activate or deactivate alarm BAR638HG_M_EN_6 p65 2005 4 27 10 56 PM 2 ...

Страница 3: ...AY 1 Weather display 2 Outdoor humidity 3 Outdoor sensor signal 4 Low battery icon for sensor 5 Indoor humidity 6 Indoor icon 7 Low battery icon for main unit 8 Alarm activated 9 Radio Frequency RF reception icon 10 Alarm setting 11 Calendar 12 Outdoor temperature 13 Indoor temperature 14 Time 15 Moon phase 1 LCD display 2 LED status indicator BAR638HG_M_EN_6 p65 2005 4 27 10 56 PM 3 ...

Страница 4: ... quickly press and hold or 3 Press MODE to confirm TABLE STAND REMOTE SENSOR THGR122NX This product is shipped with a THGR122NX Thermo Hygro Sensor that collects Temperature and Humidity data Data can be collected from up to 3 sensors Additional sensors sold separately SETUP SENSOR 1 Open the remote sensor battery compartment with a small Phillips screwdriver 2 Insert the batteries matching the po...

Страница 5: ...ilure This is normal and does not affect general product performance The reception will resume once the interference ends CLOCK The clock automatically synchronizes the current time and date when it is brought within range of the radio signal DCF77 generated from Frankfurt Germany for Central Europe model BAR638HG BAR638HG 2 or MSF60 generated from Rugby England model BAR638HGU BAR638HGU 2 NOTE Th...

Страница 6: ...ay Display DISPLAY Channel 1 Channel 2 Channel 3 New Moon Waxing Crescent First Quarter Waxing Gibbous Full Moon Waning Gibbous Last Quarter Waning Crescent SWITCH CLOCK DISPLAY Press MODE to toggle between Clock with Seconds and Clock with Weekday display ALARM This product is equipped with a 2 minute crescendo alarm VIEW ALARM SETTINGS Press The alarm time and alarm status will show in the Clock...

Страница 7: ...led properly Oregon Scientific will not be responsible for any deviations in the usage of the device from those specified in the user instructions or any unapproved alterations or repairs of the product Observe the following guidelines Never immerse the product in water This can cause electrical shock and damage the product Do not subject the main unit to extreme force shock or fluctuations in tem...

Страница 8: ... includes contact information for our Customer Care department in case you need to reach us as well as frequently asked questions and customer downloads We hope you will find all the information you need on our website however if you re in the US and would like to contact the Oregon Scientific Customer Care department directly please visit www2 oregonscientific com service support OR Call 1 800 85...

Страница 9: ...9 EN 2005 Oregon Scientific All rights reserved P N 086 003784 020 BAR638HG_M_EN_6 p65 2005 4 27 10 56 PM 9 ...

Страница 10: ...EN 10 Wireless Weather Station Model BAR638HG BAR638HG 2 BAR638HGU BAR638HGU 2 USER MANUAL BAR638HG_M_EN_6 p65 2005 4 27 10 56 PM 10 ...

Отзывы: