background image

EN

6

SET UNIT AND ALTITUDE

You can set the barometric unit of measurement (mb /
hPa or inHg) and altitude. Doing this allows the product
to take more accurate barometric measurements.

1. Press 

PRESSURE

  to select the unit of

measurement: mb / hPa or inHg.

2. Press and hold 

PRESSURE

 for 2 seconds.

3. Select the altitude (-100 to 2500 metres) in

increments of 10). Press   or   to change the
setting. Press 

PRESSURE

 to confirm.

WEATHER FORECAST

This product forecasts the next 12 to 24 hours of weather
within a 30-50 km (19-31 mile) radius with 70 to 75
percent accuracy. The weather forecast is always
displayed.

TEMPERATURE AND HUMIDITY

This product can display current, minimum, and maximum
temperatures and humidity percentage information
collected by the remote sensors and main (indoor) unit.

Outdoor data is collected and displayed every 40 seconds.
Indoor data is collected and displayed every 10 seconds.

SELECT TEMPERATURE UNIT

Slide the 

°

C / 

°

F

 switch into the desired location. The

switch is located on the front button panel. The setting for
the main unit overrides the remote sensor setting.

SELECT CHANNEL NUMBER

Press 

CHANNEL

 to switch between sensors 1-3.

The icon shows the selected sensor.

To auto-scan between sensors, press and hold

CHANNEL

 for 2 seconds. Each sensor's data will be

displayed for 3 seconds. To end auto-scan, press

CHANNEL

 or 

MEMORY

.

NOTE

 If you use a sensor that collects only temperature

data, humidity will not be shown.

NOTE

 For more information on the sensor see "Remote

Sensor THGR122NX" Section.

SWITCH CLOCK DISPLAY

Press 

MODE

 to toggle between Clock with Seconds and

Clock with Weekday display.

ALARM

This product is equipped with a 2-minute crescendo
alarm.

VIEW ALARM SETTINGS

Press         . The alarm time and alarm status will show
in the Clock Area.

SET ALARM

1. Press         to switch to alarm display.
2. Press and hold         again for 2 seconds. The alarm

settings will blink.

3. Select the hour and minute. Press   or   to change

settings. Press         to confirm.

ACTIVATE ALARM

Press      to activate or deactivate the alarm.      shows in
the Clock / Alarm Area when the alarm is activated.

SILENCE ALARM

When the alarm time is reached, the crescendo alarm
will sound for 2 minutes. To silence the alarm:

• Press 

SNOOZE / LIGHT

 to silence it for 8 minutes.

OR

• Press any key except 

SNOOZE

 to mute the alarm

and activate it again after 24 hours.

If no button is pressed, the alarm will automatically
silence after 2 minutes. It will then sound again after 8
minutes.

BAROMETER

This product tracks barometric pressure changes over
the past 24 hours to provide the weather forecast and a
trend line showing the direction of barometric change.
Barometric changes are measured by the main (indoor)
unit.

BAROMETRIC TREND

TREND

DESCRIPTION

Rising

Steady

Falling

SUNNY

PARTLY

CLOUDY

RAINY

CLOUDY

KINETIC-
WAVE
ICON
DESIG-

Indoor

Remote

Remote

Remote

NATED

Display

Display

Display

Display

DISPLAY

Channel 1 Channel 2 Channel 3

Содержание BAR629HG

Страница 1: ...7 Specifications 7 Main Unit Dimensions 7 Remote Sensor Dimensions 7 Temperature 7 Relative Humidity 8 Barometer 8 Weather Forecast 8 Remote Sensor THGR122NX 8 Clock 8 Power 8 About Oregon Scientific...

Страница 2: ...activate or deactivate RF Clock 8 RESET hole 9 MODE Change display settings 10 View alarm status set alarm 11 MEMORY View current maximum and minimum temperature humidity readings 12 CHANNEL Switch re...

Страница 3: ...RF reception icon 12 Alarm activated 13 Alarm setting 14 Time 15 Calendar 16 Pressure reading 17 Outdoor temperature trend 18 Outdoor temperature C F 19 Indoor temperature trend 20 Indoor temperature...

Страница 4: ...tteries Remote unit 2 x UM 4 AAA 1 5V batteries Insert batteries before first use matching the polarity and as shown in the battery compartment For best results install batteries in the remote sensor...

Страница 5: ...rary reception failure This is normal and does not affect general product performance The reception will resume once the interference ends CLOCK The clock automatically synchronizes the current time a...

Страница 6: ...NOTE If you use a sensor that collects only temperature data humidity will not be shown NOTE For more information on the sensor see Remote Sensor THGR122NX Section SWITCH CLOCK DISPLAY Press MODE to t...

Страница 7: ...and damage the product Do not subject the main unit to extreme force shock or fluctuations in temperature or humidity Do not tamper with the internal components Do not mix new and old batteries or bat...

Страница 8: ...mpatibility Article 3 1 b of the R TTE Directive Applied Standards ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Efficient use of radio frequency spectrum Article 3 2 of the R TTE Directive Applied Standards...

Страница 9: ...9 EN 2004 Oregon Scientific All rights reserved P N 086 003533 017...

Страница 10: ...EN 10 Easy Weather System Pro Model BAR629HG BAR629HGU User Manual...

Отзывы: