9
GB
THE RESET BUTTON
The [RESET] button is used to enhance synchronization of signals
after battery replacement or when the unit is operating in an
unfavorable way or malfunctioning. Use a blunt stylus to hold
down the button. All settings will return to their default values.
PRECAUTIONS
This unit is engineered to give you years of satisfactory service if
handled carefully.
1. Do not immerse the unit in water.
2. Do not clean the unit with abrasive or corrosive materials.
3. Do not subject the unit to snow or excessive force, shock, dust,
temperature or humidity.
4. Do not tamper with the unit’s internal components.
5. Do not mix new and old batteries or batteries of different
specifications.
SPECIFICATIONS
Temperature Measurement
Main unit
Operating range
: -5.0°C to +50.0°C
(23.0°F to 122.0°F)
Temperature resolution
: 0.1°C (0.2°F)
Remote unit
Operating range
: -20.0°C to +60.0°C
(-4.0°F to 140.0°F)
Temperature resolution
: 0.1°C (0.2°F)
RF Transmission Frequency : 433 MHz
RF Transmission Range
: Maximum 30 meters
Temperature sensing cycle
: around 30 seconds
Radio Controlled Clock
Clock
: 24hr format with hh:mm:ss
(DCF version)
12hr format with hh:mm:ss
(MSF version)
Calendar
: Day / Month
day-of-week selectable in
5 language (E, D, F, I, Sp )
Alarm
: 2 minutes crescendo
Snooze
: 8 minutes
Power
Main unit
: 4 pcs UM-3 or “AA” 1.5V
alkaline battery
AC/DC 3V power adapter
(For continuous projection)
Remote sensing unit
: 2 pcs UM-4 or “AAA” 1.5V
alkaline battery