background image

EN

13

The house icon
indicates that the
radio-controlled
clock is ON. No
icon means that it
is OFF.

SET CLOCK

You only need to do this if you have disabled the radio-
controlled clock, or if you are too far from a RF signal.

1.

Press 

SELECT 

to navigate to the Clock Area.

 will show next to the Area.

2.

Press and hold 

MODE 

for 2 seconds.

3.

Select the 2

nd

 time zone offset hour (+/-23 hours),

12/ 24 hour format, hour, minute, year, date/month
format, month, date, and display language, and
(optional) volume level for the Audio Broadcast.
Press 

UP 

or 

DOWN 

to change the setting. Press

MODE 

to confirm.

The language options are (E) English,

(F) French, (D) German, (I) Italian, and (S) Spanish. The
language you select determines the weekday display
and the spoken language for the Audio Broadcast.

Audio Broadcast must be activated (

  19)

before you can set the volume level. The number of bars
shown after the speaker icon ( 

 ) at the BOTTOM of

the display indicates the level (Low, Medium, or High).

ALARMS

This product has 2 alarms: the Daily Alarm and a Pre-
Alarm for snowy weather. The Daily Alarm can be set to
go off at the same time every day and you can select
either Beep or Talking Alarm. The Pre-Alarm sounds only
when the Daily Alarm is activated and the recorded
temperature from Channel 1 Sensor falls to 2

°

C

(35.6 

°

F) or below.

SET DAILY ALARM

1.

Press 

SELECT 

to navigate to the Clock Area.  will

show next to the Area.

2.

Press 

ALARM 

 to view the Alarm. (AL will show

at the top.)

3.

Press and hold 

ALARM 

 for 2 seconds.

4.

Select the hour and minute. Press 

UP 

or 

DOWN 

to

change settings. Press 

ALARM 

 to confirm.

NOTE

NOTE

BAR321/323HGN English R3 R

3/27/04, 11:25 AM

13

Black

Содержание BAR321HGN

Страница 1: ...Set Clock 13 Alarms 13 Set Daily Alarm 13 Set Pre Alarm 14 Activate Alarm 14 Snooze 15 Barometer 15 View Barometer Area 15 Select Measurement Unit 15 View Barometer History 16 Bar Chart Display 16 Set...

Страница 2: ...20 Warnings 20 Troubleshooting 21 Specifications 22 Main unit dimensions 22 Remote unit dimensions 22 Temperature 22 Relative humidity 22 Barometer 22 Remote unit RTGR328N 22 Radio controlled clock 23...

Страница 3: ...mote sensor BAR323HGN BAR321HGN Main unit RTGR328N Remote sensor UVR138 UV Sensor Keep this manual handy as you use your new product It contains practical step by step instructions as well as technica...

Страница 4: ...alarms calendar battery status 3 Temperature Humidity Comfort Zone Area Readings and trend lines comfort zone sensor channel number sensor battery status 4 UVI Barometer Area UV level and barometric...

Страница 5: ...tting activate radio controlled clock and audio broadcast 6 DOWN decrease setting deactivate radio controlled clock and audio broadcast 7 ALARM view alarm status set alarm 8 MEMORY view current and sa...

Страница 6: ...bottom 4 C F button in battery compartment 5 mb inHg button in battery compartment 6 RESET button in battery compartment GETTING STARTED Refer to the Battery section 8 for more information about the b...

Страница 7: ...ption 2 Channel number 3 Low battery icon 4 Time 5 Temp C or F 6 Humidity 7 Temp Humidity 1 Wall mount 2 Channel switch 1 5 3 RESET 4 C F 5 Search 6 EU UK radio signal format switch 7 Battery compartm...

Страница 8: ...place 2 Grasp the battery compartment by the sides and gently pull to open It will not completely detach from the main unit AC ADAPTER MAIN UNIT The AC power adapter socket is located inside the batt...

Страница 9: ...ss MODE to switch options or ALARM to switch between Clock and Alarm 3 Press and hold MODE for 2 seconds to enter setting MODE 4 Press UP or DOWN to change settings 5 Press MODE to confirm WALL MOUNT...

Страница 10: ...he UVR138 refer to the UVR138 User Manual THERMO HYGRO SENSOR SETUP RTGR328N 1 Open the battery compartment with a small Phillips screwdriver 2 Insert the batteries 3 Set the channel and radio signal...

Страница 11: ...km 932 miles of a RF signal the reception icon will blink during reception When the sensor receives the radio controlled clock signal and is paired with the main unit the clock in the main unit will...

Страница 12: ...signals are collected by the remote sensor RTGR328N whenever it is within 1500 km 932 miles of a signal Initial reception takes 2 10 minutes and is initiated when you first setup the unit and whenever...

Страница 13: ...and the spoken language for the Audio Broadcast Audio Broadcast must be activated 19 before you can set the volume level The number of bars shown after the speaker icon at the BOTTOM of the display i...

Страница 14: ...tivate the Daily Alarm 2 Press ALARM to switch to Pre Alarm view will show at the top 3 Press and hold ALARM for 2 seconds NOTE 4 Press UP or DOWN to select 15 30 45 or 60 minutes This is the amount o...

Страница 15: ...ent time at the set time Daily Beep Alarm is activated and will sound at the set time Pre Alarm is activated and will sound at the specified time if the temperature falls to 2 C 35 6 F or below Alarm...

Страница 16: ...e living This ensures that the barometric pressure readings are accurate 1 Navigate to the Barometer Area 2 Press and hold HISTORY for 2 seconds 3 Press UP or DOWN to set the altitude in 10 meter incr...

Страница 17: ...ELECT to navigate to the Barometer Area then press MODE to display the UV icon and data Refer to the UVR138 User Manual for more information NOTE RAINY SNOWY ICON DESCRIPTION TEMPERATURE AND HUMIDITY...

Страница 18: ...y to view current maximum and minimum records for the selected sensor To clear the records press and hold MEMORY for 2 seconds A beep will sound to confirm that the memory has been cleared TEMPERATURE...

Страница 19: ...ORECAST Press SNOOZE LIGHT for 2 seconds Audio Broadcast must be activated for the feature to work SET BROADCAST TIMES There are 2 Broadcast settings Hourly during a specified period of time such as 6...

Страница 20: ...when you change the batteries and whenever performance is not behaving as expected for example unable to establish radio frequency link with remote unit or radio controlled clock When you press RESET...

Страница 21: ...UBLESHOOTING Check here before contacting our customer service department Problem Symptom Remedy Barometer Strange readings Set altitude unit 15 Calendar Strange date month Change language 13 Clock Ca...

Страница 22: ...0 1 C 0 2 F Comfort 20 C to 25 C 68 F to 77 F Memory Min Max Trend 5 C or F RELATIVE HUMIDITY Range 25 to 95 Resolution 1 Comfort 40 to 70 Memory Min max Trend 3 BAROMETER Unit mb hPa or inHg Range 50...

Страница 23: ...at Calendar DD MM or MM DD weekday in 5 languages E G F I S Alarm Daily Pre Alarm 2 minute crescendo Snooze 8 minutes POWER Main unit Power adapter 6V AC adapter Batteries 3 x UM 3 AA 1 5V alkaline ba...

Страница 24: ...ectrum Article 3 2 of the R TTE Directive Applied Standards EN 300 220 3 2000 Additional information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EC the EMC D...

Отзывы: