SENSOR SEARCH

To search for a Thermo / Hygro sensor, press 

SELECT

to navigate to the Temperature/ Humidity / Comfort Zone
Area.  will show next to the Area. Then, simultaneously
press and hold 

MEMORY 

and 

CHANNEL 

for 2 seconds.

To search for the UV sensor, press 

SELECT 

to navigate

to the UVI / Barometer Area.  will show next to the Area.
Then,  press  and  hold 

MEMORY 

and 

CHANNEL 

for

2 seconds.

If  the  sensor  is  still  not  found,  check  the

batteries.

CLOCK AND CALENDAR

This product tracks the time and date based on radio-
controlled signals from the RTGR328N remote sensor,
or manual settings that you enter.

NOTE

RADIO-CONTROLLED CLOCK

The time and date are automatically updated by radio-
controlled  clock  signals  from  official  time-keeping
organizations  in  Frankfurt  (Germany)  and  Rugby
(England) unless you disable this feature. The signals
are  collected  by  the  remote  sensor  (RTGR328N)
whenever it is within 1500 km (932 miles) of a signal.

Initial  reception  takes  2  –  10  minutes,  and  is  initiated
when you first setup the unit, and whenever you press

RESET

.  Once  complete,  the  reception  icon  will  stop

blinking.

The  

  icon shown in the Clock Area indicates 2 factors:

• Connection between the main unit and the

sensor that collects RF signals ( 

 )

• RF signal reception ( 

 )

Both parts will show ( 

 ) when the sensor that receives

RF signals is selected and the RF signal is strong.  (If you
select another sensor,  

 or 

 will show to indicate

whether the RF signal is strong.)

If no signal is found, check the sensor batteries.

TURN RADIO-CONTROLLED CLOCK ON/OFF

If  you  wish  to  manually  set  the  clock,  you  must  first
disable the radio-controlled feature. To do this, navigate
to the Clock / Alarm Area. Then, press and hold 

DOWN

on the main unit for 2 seconds. To enable it, navigate to
the  Clock  /  Alarm Area,  then  press  and  hold 

UP 

for

2 seconds.

BAR321/323HGN English New R2 OP

8/17/04, 12:55 PM

12

Black

Содержание BAR321HGA

Страница 1: ...Talking Wireless Weather Station Model BAR321 323HGN User Manual BAR321 323HGN EN New C R2 OP 8 17 04 12 56 PM 1 Black...

Страница 2: ...ON OFF 12 Set Clock 13 Alarms 13 Set Daily Alarm 13 Set Pre Alarm 14 Activate Alarm 14 Snooze 15 Barometer 15 View Barometer Area 15 Select Measurement Unit 15 View Barometer History 16 Bar Chart Disp...

Страница 3: ...light 20 Reset System 20 Safety and Care 20 Warnings 20 Troubleshooting 21 Specifications 22 Main unit dimensions 22 Remote unit dimensions 22 Temperature 22 Relative humidity 22 Barometer 22 Remote u...

Страница 4: ...your home In this box you will find Main unit Remote sensor RTGR328N Optional UV sensor UVR138 AC adapter Batteries BAR321HGN BAR321HGN Main unit RTGR328N Remote sensor BAR323HGN BAR321HGN Main unit...

Страница 5: ...larms calendar battery status 3 Temperature Humidity Comfort Zone Area Readings and trend lines comfort zone sensor channel number sensor battery status 4 UVI Barometer Area UV level and barometric pr...

Страница 6: ...ng activate radio controlled clock and audio broadcast 6 DOWN decrease setting deactivate radio controlled clock and audio broadcast 7 ALARM view alarm status set alarm 8 MEMORY view current and saved...

Страница 7: ...ttom 4 C F button in battery compartment 5 mb inHg button in battery compartment 6 RESET button in battery compartment GETTING STARTED Refer to the Battery section 8 for more information about the bat...

Страница 8: ...ion 2 Channel number 3 Low battery icon 4 Time 5 Temp C or F 6 Humidity 7 Temp Humidity 1 Wall mount 2 Channel switch 1 5 3 RESET 4 C F 5 Search 6 EU UK radio signal format switch 7 Battery compartmen...

Страница 9: ...lace 2 Grasp the battery compartment by the sides and gently pull to open It will not completely detach from the main unit AC ADAPTER MAIN UNIT The AC power adapter socket is located inside the batter...

Страница 10: ...MODE to switch options or ALARM to switch between Clock and Alarm 3 Press and hold MODE for 2 seconds to enter setting MODE 4 Press UP or DOWN to change settings 5 Press MODE to confirm WALL MOUNT STA...

Страница 11: ...UVR138 refer to the UVR138 User Manual THERMO HYGRO SENSOR SETUP RTGR328N 1 Open the battery compartment with a small Phillips screwdriver 2 Insert the batteries 3 Set the channel and radio signal fo...

Страница 12: ...932 miles of a RF signal the reception icon will blink during reception When the sensor receives the radio controlled clock signal and is paired with the main unit the clock in the main unit will be...

Страница 13: ...nals are collected by the remote sensor RTGR328N whenever it is within 1500 km 932 miles of a signal Initial reception takes 2 10 minutes and is initiated when you first setup the unit and whenever yo...

Страница 14: ...d the spoken language for the Audio Broadcast Audio Broadcast must be activated 19 before you can set the volume level The number of bars shown after the speaker icon at the BOTTOM of the display indi...

Страница 15: ...vate the Daily Alarm 2 Press ALARM to switch to Pre Alarm view will show at the top 3 Press and hold ALARM for 2 seconds NOTE 4 Press UP or DOWN to select 15 30 45 or 60 minutes This is the amount of...

Страница 16: ...t time at the set time Daily Beep Alarm is activated and will sound at the set time Pre Alarm is activated and will sound at the specified time if the temperature falls to 2 C 35 6 F or below Alarm is...

Страница 17: ...iving This ensures that the barometric pressure readings are accurate 1 Navigate to the Barometer Area 2 Press and hold HISTORY for 2 seconds 3 Press UP or DOWN to set the altitude in 10 meter increme...

Страница 18: ...ECT to navigate to the Barometer Area then press MODE to display the UV icon and data Refer to the UVR138 User Manual for more information NOTE RAINY SNOWY ICON DESCRIPTION TEMPERATURE AND HUMIDITY Th...

Страница 19: ...o view current maximum and minimum records for the selected sensor To clear the records press and hold MEMORY for 2 seconds A beep will sound to confirm that the memory has been cleared TEMPERATURE AN...

Страница 20: ...ECAST Press SNOOZE LIGHT for 2 seconds Audio Broadcast must be activated for the feature to work SET BROADCAST TIMES There are 2 Broadcast settings Hourly during a specified period of time such as 6 8...

Страница 21: ...n you change the batteries and whenever performance is not behaving as expected for example unable to establish radio frequency link with remote unit or radio controlled clock When you press RESET all...

Страница 22: ...o scale TROUBLESHOOTING Check here before contacting our customer service department Problem Symptom Remedy Barometer Strange readings Set altitude unit Calendar Strange date month Change language Clo...

Страница 23: ...1 C 0 2 F Comfort 20 C to 25 C 68 F to 77 F Memory Min Max Trend 5 C or F RELATIVE HUMIDITY Range 25 to 95 Resolution 1 Comfort 40 to 70 Memory Min max Trend 3 BAROMETER Unit mb hPa or inHg Range 500...

Страница 24: ...igital cameras MP3 players children s electronic learning products and games projection clocks health and fitness gear weather stations and digital and conference phones The website also includes cont...

Страница 25: ...R TTE Directive Applied Standards ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Efficient use of radio frequency spectrum Article 3 2 of the R TTE Directive Applied Standards ETSI EN 300 220 3 Ver1 1 1 2000...

Страница 26: ...2004 Oregon Scientific All Rights Reserved 086 003370 048 BAR321 323HGN EN New Back R2 OP 8 17 04 12 56 PM 1 Black...

Отзывы: