background image

12

GB

5. Enter the minutes using 

 ]

 and 

 ](CLOCK)

.

6. Press  

ALARM

 ]

 to exit. The 

 

]

 icon for the alarm

chosen will be displayed indicating the alarm set above is now

armed.

You can also arm or disarm an alarm by pressing the 

[  ON / OFF ]

(CLOCK)

 button.

When an alarm is armed, it will go off at the set time.
The four-step crescendo function allows the alarm to start off gently

and step up its intensity every 20 seconds for four times. Without

interruption, the alarm will go off for a total of two minutes. If no key

is pressed to turn off the alarm within these 2 minutes, the alarm will

go off once more after 8 minutes.
If a second alarm goes off when the first alarm is sounding off, the first

alarm will be disabled automatically.

HOW TO STOP AN ALARM

To stop an alarm, you can use either press  

[

 ALARM 

]

 button or

[  ON / OFF ] (CLOCK)

 button.

Pressing 

ALARM 

]

 will stop the alarm, which is still armed and

will activate at the set time the following day.
If 

[  ON / OFF ] (CLOCK)

 button is pressed instead, the alarm

will be stopped and deactivated all together.

NOTE ON °C AND °F

The temperature display designation of °C or °F on the main display

unit will override the display selection made on the remote sensor.

Whatever the display unit of the remote sensor is, it will only apply

to the remote sensor itself and the temperature unit will automati-

cally be converted to the one of the main unit. (i.e. °C)

MAINTENANCE

When handled properly, this unit is engineered to give you years

of satisfactory service. Here are a few product care instructions:
1. Do not immerse the unit in water. If the unit comes in contact

with water, dry it immediately with a soft lint-free cloth.

2. Do not clean the unit with abrasive or corrosive materials.

Abrasive cleaning agents may scratch the plastic parts and

corrode the electronic circuit.

3. Do not subject the unit to excessive: force, shock, dust,

temperature, or humidity. Such treatment may result in

malfunction, a shorter electronic life span, damaged batteries, or

distorted  parts.

4. Do not tamper with the unit’s internal components. Doing so

will terminate the unit’s warranty and may cause damage. The

unit contains no user-serviceable parts.

5. Only use new batteries as specified in this instruction manual.

Do not mix new and old batteries as the old batteries may leak.

6. Read this instruction manual thoroughly before operating the

unit.

Содержание BAR182HG

Страница 1: ... LCD for displaying weather forecast information in outdoor temperatures and relative humidity radio frequency RF controlled calendar clock clock display of 2nd time zone and dual daily alarms Also the main unit can support up to three remote sensors Other features include weekday display in four abbreviated languages crescendo alarm and interchangeable clock display modes MAIN FEATURES MAIN UNIT ...

Страница 2: ...ure and humidity readings and erases memory data I CHANNEL BUTTON Toggles among the remote sensor channels CLOCK J ON OFF BUTTON Enables or disables the daily alarms K BUTTON Decreases the value of a setting L I BUTTON Advances the value of a setting TEMP RH ALARM M ON OFF BUTTON TEMP RH ALARM Enables disables HI LO temp alarm and HI LO RH alarm N HI LO BUTTON TEMP RH ALARM Set the upper or lower ...

Страница 3: ...ESET Returns all settings to default values F BATTERY COMPARTMENT Accommodates two UM 4 or AAA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so ...

Страница 4: ...aline batteries 4 Replace the battery compartment door and the table stand BATTERY AND CHANNEL INSTALLATION REMOTE UNIT The remote thermo hygro sensor unit uses two 2 UM 4 or AAA size alkaline batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C...

Страница 5: ... Remote unit Wall mount Table Stand THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 40 second intervals Also for approximately a 3 mi...

Страница 6: ...ed in the box under the kinetic wave DISCONNECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEM to enforce an immediate search If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note that when the temperature falls below freezing point the batteries...

Страница 7: ... mode Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Presseither CHANNEL MEM HI LO I ON OFF TEMP RH AL THE COMFORT LEVEL ICONS The comfort level indicators COM WET or DRY will tell you if the current environment is comfortable too wet or too dry The comfort indicator will appear on the display when the follow ing conditions are satisfied Indicator displays on th...

Страница 8: ...ed 2 Press MEM once to display the maximum temperature and humidity and again the minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEM for 2 seconds If you press MEM now the maximum and minimum recordings will have the same values as the current ones until different readings are recorded HOW TO USE CHANNEL 1 TEMPERATURE HUMI...

Страница 9: ...the alarm If in another channel other than channel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for a 1 minute Press CHANNEL MEM HI LO I ON OFF to TEMP RH AL momentarily stop the alarm The alarm will activate again if the limit continues to exceed the set limit Note If a second limit is passed whi...

Страница 10: ...zone Day Month of alternate time zone Each press on the MODE button will toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the ALARM button is pressed ABOUT RADIO RECEPTION The BAR182HG is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the BAR182HG is wit...

Страница 11: ... For the language display you can choose among English E German D French F and Italian I Weekday is in the usual sequence of Monday through Sunday For the 2nd time zone which is indicated by the ZONE icon enter the hour offset using the and CLOCK buttons and the BAR182HG will calculate the second zone time accordingly If there is an item you do not wish to change simply press MODE to bypass the it...

Страница 12: ...ignation of C or F on the main display unit will override the display selection made on the remote sensor Whatever the display unit of the remote sensor is it will only apply to the remote sensor itself and the temperature unit will automati cally be converted to the one of the main unit i e C MAINTENANCE When handled properly this unit is engineered to give you years of satisfactory service Here ...

Страница 13: ...ions to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment R TTE Compliance Note This device complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directive if used for its intended use and that the following standard s has been applied Electromagnetic compatibility Article 3 1 b of the R TTE Dire...

Страница 14: ...14 GB COUNTRIES RTTE APPROVAL COMPLIED Austria Belgium Denmark Finland France Germany Greece Italy Luxembourg Netherlands Portugal Spain Sweden UK and Ireland ...

Отзывы: