background image

13

GB

Temperature resolution

: 0.1°C  (0.2°F)

Relative  Humidity  Operating

: 25% RH to 90% RH

range

Remote thermo-hygro unit

Proposed  operating  range

: -20.0°C to +60.0°C

(-4.0°F to 140.0°F)

Temperature resolution

: 0.1°C  (0.2°F)

Relative  Humidity  Operating

: 25% RH to 90% RH

range

Power

Main  unit

: use four (4) UM-3 or “AA”

1.5V alkaline battery

Remote  sensing  unit

: use two (2) UM-4 or “AAA”

1.5V alkaline battery

Weight

Main  unit

: 216gm  (without  battery)

Remote  sensing  unit

: 63 gm (without battery)

Dimension

Main  unit

: 136 x 90 x 35 mm (L x Wx D)

Remote  sensing  unit

: 92 x 60 x 20mm (L x Wx D)

NOTE ON COMPLIANCE

Warning

:    Changes  or  modifications  to  this  unit  not  expressly

approved by the party responsible for compliance could void the
user’s  authority  to  operate  the  equipment.

R&TTE Compliance Note

This device complies with the essential requirements of Article 3 of
the R&TTE 1999/5/EC Directive, if used for its intended use and
that  the  following  standard(s)  has  been  applied:

Electromagnetic compatibility (Article 3.1.b of the R&TTE Direc-
tive)

Applied  standards

ETS 300 683 : 1997

Efficient  use  of  the  radio  frequency  spectrum  (Article  3.2  of  the
R&TTE Directive)

Applied  standards

EN300  220  –1  :  1997

INTENDED USE OF THE DEVICE

CAUTION

— The content of this manual is subject to change without

further notice.

— Due  to  printing  limitation,  the  displays  shown  in  this

manual may differ from the actual display.

— The contents of this manual may not be reproduced without

the permission of the manufacturer.

Содержание BAR122HG

Страница 1: ...mation in outdoor temperatures and relative humidity radio frequency RF controlled calendar clock clock display of 2nd time zone and dual daily alarms Also the main unit can support up to three remote sensors Other features include weekday display in four abbreviated languages four step crescendo alarm and interchangeable clock display modes MAIN FEATURES MAIN UNIT A B C G H 4 3 3 M H z C A B L E ...

Страница 2: ...en the alarm time is displayed I TIME BUTTON Decreases the value of a setting J TIME BUTTON Advances the value of a setting K 24 hr OFF BUTTON Displays the alarm time or changes the alarm set time L ON OFF BUTTON TEMP RH ALARM Enables disables HI LO temp alarm and HI LO RH alarm M HI LO BUTTON TEMP RH ALARM Set the upper or lower temperature alarm limits of individual channels Confirms alarm setti...

Страница 3: ... E RESET Returns all settings to default values F BATTERY COMPARTMENT Accommodates two AAA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so for ...

Страница 4: ... compartment door BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 4 or AAA size alkaline batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C F slide switch 4 Insert the batteries strictly according ...

Страница 5: ...mote unit Wall mount Table Stand THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 40 second intervals Also for approximately a 3 minut...

Страница 6: ...displayed in the box under the kinetic wave DISCONNECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEMORY to enforce an immediate search If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note that when the temperature falls below freezing point the...

Страница 7: ...e Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Presseither CHANNEL MEMORY HI LO ON OFF TEMP RH AL THE COMFORT LEVEL ICONS The comfort level indicators COMFORT WET or DRY will tell you if the curent environment is comfortable too wet or too dry The comfort indicator will appear on the display when the follow ing conditions are satisfied Indicator displays on th...

Страница 8: ...d 2 Press MEMORY once to display the maximum temperature and humidity and again the minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEMORY for 2 seconds Ifyoupress MEMORY now themaximumandminimumrecordings will have the same values as the current ones until different readings are recorded HOW TO USE CHANNEL 1 TEMPERATURE HU...

Страница 9: ...e alarm If in another channel other than channel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for a 1 minute Press CHANNEL MEMORY HI LO ON OFF to TEMP RH AL momentarily stop the alarm The alarm will activate again if the limit continues to exceed the set limit Note If a second limit is passed whil...

Страница 10: ...l toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the button is pressed ABOUT RADIO RECEPTION The BAR122HG is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the BAR122HG is within range its radio control mechanism will override all manual settings When ...

Страница 11: ... date are displayed in 24 HOUR clock format For the language display you can choose among English E German D French F and Italian I Weekday is in the usual sequence of Monday through Sunday For the 2nd time zone which is indicated by the ZONE icon enter the hour offset using the TIME and TIME buttons and the BAR122HG will calculate the second zone time accordingly If there is an item you do not wi...

Страница 12: ...utton is pressed instead the alarm will be stopped and deactivated all together MAINTENANCE When handled properly this unit is engineered to give you years of satisfactory service Here are a few product care instructions 1 Do not immerse the unit in water If the unit comes in contact with water dry it immediately with a soft lint free cloth 2 Do not clean the unit with abrasive or corrosive materi...

Страница 13: ...ressly approved by the party responsible for compliance could void the user s authority to operate the equipment R TTE Compliance Note This device complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directive if used for its intended use and that the following standard s has been applied Electromagnetic compatibility Article 3 1 b of the R TTE Direc tive Applied standards ...

Страница 14: ...14 GB COUNTRIES RTTE APPROVAL COMPLIED Austria Belgium Denmark Finland France Germany Greece Italy Luxembourg Netherlands Portugal Spain Sweden UK and Ireland ...

Отзывы: