background image

9

GB

Indicator

displays

on the unit

Temperature

Range

20°C to 25°C
(68°F to 77°F)

-5°C -+ 50°C
(23°F - 122°F)

-5°C -+ 50°C
(23°F - 122°F)

Humidity

Range

40%RH-
70%RH

OVER-
70%RH

Below
40%RH

Shows that the

Current

Environment

Ideal range for
both relative
humidity and
temperature

Contains excess
moisture.

Contains
inadequate
moisture

No

Indicator

Less than
20°C( 68°F)
or More than
25°C (77°F)

40%RH
to
70%RH

No comment

COMFORT

WET

DRY

HOW TO CHECK THE BAROMETRIC

PRESSURE

The current and historical barometric pressure is shown on the
atmospheric pressure window.

For use at a higher altitudes, such as in the mountains, sea-level
barometric pressure applies.

  In this case, press and hold [HISTORY]

button to enter the altitude compensation setting mode.  Use the UP
(+) or DOWN (-) button to select from –100 to 2500 meters
(whichever appropriate).  Press [HISTORY] button to confirm and
exit.

The atmospheric pressure can be displayed in mb/hPa or inHg.  The
pressure unit is selected on the atmospheric pressure slide switch
inside the battery compartment.

If you want to check the pressure history for a particular hour
during the past 24 hours, press the [HISTORY] button.  Each press
on the button will go back by an hour.  Holding down the button
will increase the value rapidly.

LOW BATTERY INDICATION

When it is time to replace batteries, the respective low battery
indicator  [

] will show up when the corresponding channel is

selected.  The battery level of the main unit is shown on the Weather
Forecast Window when it is running low.

HOW TO WALL MOUNT OR USE THE

TABLE STAND (REMOTE UNIT)

The unit can be wall-mounted using its recessed screw holes or
place on a flat surface using the fold out table stand.

                            

  Wall-mount          Table stand

913hg-e.p65

04/30/2002, 6:00 PM

9

Содержание BAA913HG

Страница 1: ...ing device has several weather related functions A main feature is that it takes and records temperatures and humidities in more than one location Using a wirelessremotethermo hygrosensor itcansimultaneouslymonitor temperatures and humidities in three remote locations The unit will show temperature and humidity trends as well as record maximum and minimum temperature and humidity readings BAA913HG...

Страница 2: ...s barometric reading A5 TIME DATE ALARM WINDOW Displays the current time date day month and year daily alarm or Pre alarm function B CONTROL BUTTONS B1 CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL BUTTON Displays the temperature and humidity readings of the indoor or remote sensor B2 MEMORY MEMORY MEMORY MEMORY MEMORY BUTTON Displays minimum and maximum temperature and humidity readings and erases memo...

Страница 3: ...mb hPa or inHg pressure unit display C3 RESET SLOT Resets the unit by returning all settings to their default values C4 C F SLIDE SWITCH SelectsbetweenCentigrade C orFahrenheit F temperature unit display C5 RETRACTABLE TABLE STAND Easy open table stand with lock FEATURES REMOTE THERMO HYGRO SENSOR 913hg e p65 04 30 2002 5 59 PM 3 ...

Страница 4: ...e unit first Then proceed with inserting the batteries for the main unit 2 Position the remote unit and the main unit within effective transmission range In usual circumstances the effective range is 30 meters 3 Though the remote unit is weather proof it should be placed away form direct sunlight rain or snow BATTERY INSTALLATION MAIN UNIT 1 Gently lift the tab on the battery compartment door 2 In...

Страница 5: ... use the UP or DOWN button to change the minutes Note When changes are made to this setting the seconds will start fromzero Press MODE again the calendar settings are displayed and the year is flashing Use the UP or DOWN button to change the year Press MODE again The day D and month M symbols will flash The unit provides an option that allows either the day or the month to be indicated first Using...

Страница 6: ...on PRE ALARM FUNCTION FOR CHANNEL 1 REMOTE SENSOR The alarm function also has a pre alarm feature which can alert the user before their preset alarm time if weather conditions changes This pre alarm function applies to Channel 1 Remote Sensor only To enable this function first activate the alarm function Then enter the Pre Alarm mode by pressing the ALARM button twice The Pre Al icon will be displ...

Страница 7: ... will be displayed To force the main unit to search for remote sensor signals press MEMORY and CHANNEL simultaneously If that fails check that the remote sensor is still in place Make sure the transmission is within range and the path is clear of obstacles and interference Repeat this procedure whenever you find discrepancies between the display on the main unit and the display on the remote senso...

Страница 8: ...e predictions that cover the next 12 to 24 hours It may not necessarily reflect the current situation 3 The Sunny icon as applies to night time implies clear weather COMFORT LEVEL INDICATORS ThecomfortlevelindicatorsCOMFORT WETorDRYwilltellyou if the curent environment is comfortable too wet or too dry The comfort indicator will appear on the display when the following conditions are satisfied Ris...

Страница 9: ...lect from 100 to 2500 meters whichever appropriate Press HISTORY button to confirm and exit The atmospheric pressure can be displayed in mb hPa or inHg The pressure unit is selected on the atmospheric pressure slide switch inside the battery compartment If you want to check the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the button will go...

Страница 10: ... care instructions 1 Do not immerse the unit in water If the unit comes in contact with water dry it immediately with a soft lint free cloth 2 Do not clean the unit with abrasive or corrosive materials Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust temperature or humidity Such treatment may result in...

Страница 11: ...emperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz No of Remote unit Up to 3 units RF Transmission Range 30 meters Temperature sensing cycle around 40 seconds Relative Humidity measurement Measuring Range 25 to 95 RH at 25 C 77 F Resolution of Humidity 1 RH Barometric Pressure measurement Pressure measuring range 795 to 1050mb hPa 23 48 to 31 01 inHg CAUTION The content of this ma...

Страница 12: ...ential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Efficient use of radio frequency spectrum Article3 2oftheR TTEDirective applied standard s EN 300 220 1 2 3 1997 Electromagnetic compatibility Article3 1 boftheR TTEDirective applied standard s ETS 300 683 1997 Safety of information technology equi...