This manual is intended for end-users of the HRC-EcoMax and HRC-MaxComfort 
balanced ventilation systems. This manual contains important information 
about the operation and maintenance of the ventilation unit with heat 
recovery, remote control, CO

2

 room sensor and CO

2

 control sensor.  

The installer manual can be found on the right side of the unit.

This manual covers the following models:

HRC-300-EcoMax
HRC-300-MaxComfort
HRC-400-EcoMax
HRC-400-MaxComfort
HRC-500-EcoMax
HRC-500-MaxComfort

Содержание HRC-300-EcoMax

Страница 1: ...ems This manual contains important information about the operation and maintenance of the ventilation unit with heat recovery remote control CO2 room sensor and CO2 control sensor The installer manual...

Страница 2: ...2 Index 1 Safety instructions 4 2 General operation of balanced ventilation system 5 3 Product information 7 4 Operating the unit 8 5 Maintenance 11 6 Malfunctions 15 7 Certification and warranty 18...

Страница 3: ...es with a properly isolated home As you need enough fresh air in your home the airflow needs to be constant You require approximately 25m of fresh air an hour so good ventilation is a necessity Just o...

Страница 4: ...ion all parts that may lead to personal injury are safely contained inside the housing Do not open the housing Always follow the safety instructions warnings comments and instructions in this manual F...

Страница 5: ...on of the polluted air to and from the unit 6 Roof outlet incl airtight connection 7 Wall transit In balance The HRC EcoMax MaxComfort is equipped with two fan modules an extractor ventilator and a su...

Страница 6: ...ure sensor which measures the moisture content in the extracted air from the kitchen bathroom and toilet If the built in humidity sensor detects that the humidity is rising for example during cooking...

Страница 7: ...r flow rate m h at max 200 Pa 300 300 400 400 500 500 Tube connection mm 150 150 180 180 180 180 Preheater no yes no yes no yes Filter class ISO16890 2x coarse 65 supply ePM1 70 extract coarse 65 2x c...

Страница 8: ...thin the home Setting 3 High High setting For use during cooking showering or parties 4 2 Operation using RF remote control The balance ventilator can be operated using a wireless remote control 15 RF...

Страница 9: ...l using the CO2 Room sensor This sensor measures the CO2 concentration air quality in the room and makes the unit ventilate more if necessary This avoids unnecessary ventilation which benefits the ene...

Страница 10: ...ased on moisture and CO2 1 Setting 1 Temporary low setting 60 min 2 Setting 2 Temporary medium setting 60 min 3 Setting 3 Temporary high setting 60 min CO2 Plus system It is possible to have a CO2 Roo...

Страница 11: ...er 3 years Installer Clean ventilators 1x per 3 years Installer Clean condensation extractor 1x per 3 years Installer Clean the heat exchanger 1x per 5 years Installer Clean the inside of the unit 1x...

Страница 12: ...ns can also be found on the top of the unit 5 Replace the filter handles in the recess on the front of the unit On the inside of the covers you will see an L or R marking to indicate on which side the...

Страница 13: ...ing a hinge movement Caution Do not throw empty batteries into the household waste but take them to the collection points for chemical waste Maintenance CO2 Room sensor Control sensor The CO2 Room sen...

Страница 14: ...14 User maintenance log Date Action Clean filters Clean valves Clean controls Fill condensation extractor...

Страница 15: ...reen Battery almost empty 1x orange 2x green Reset remote control carried out 2x orange Filter indication active 3x orange II CO2 Room sensor 15RF When the status LED on the CO2 If the room sensor is...

Страница 16: ...e Overview of indications on display circuit board Indication Message on display circuit board Configuration mode active continuous green In operation 1x green Start up unit RF communication 1x orange...

Страница 17: ...ter warning on the display is an indication to clean or replace the filters on time When the chosen interval time in the printed circuit board has elapsed it will send a signal to the display on the u...

Страница 18: ...this must be reported to the installer State the type and serial number which can be found on the type sticker under the unit Orcon bv reserves the right to change the construction and or configurati...

Страница 19: ...19...

Страница 20: ...Landjuweel 25 3905 PE Veenendaal Postbus 416 3900 AK Veenendaal t 31 0 318 54 47 00 info orcon nl www orcon nl...