background image

Your thermostat carries an 24 month warranty from 

date of purchase. Service outwith the warranty 

period may incur a charge.

Warranty

  

Wiring your thermostat

Please note: 

Do not over-tighten the terminals in your thermostat 

as damage may occur.

 

6. System function settings

With power off, press and hold both M and       for 5 

seconds to enter the System Functions. Press M to 

scroll through the available functions, and use the  

and       arrows to change the available options. 

Your thermostat will automatically exit the System 

Functions settings after approximately 15 - 20 

seconds of inactivity. All settings are automatically saved. 

Please note:

1.“Err” on your thermostat indicates a fault without the external 

 Your thermostat will be inoperative until the error is rectified.

(floor) sensor. 

    2. When sensor selection is “AL” (option 4 below) the room 

temperature will be displayed on your thermostat  by default. 

The floor temperature can be displayed temporarily by pressing 

 the      button for three seconds. Your thermostat will revert to 

display the room temperature after several seconds.

 

Code

Function

Setting and options

Default

1

Temperature

compensation

-9 to +9

(for internal sensor)

-2

2

01

3

Button

locking

00: All

buttons

are locked except power button.

01

All

buttons

are locked.

01

4

5

Min. Set Temp.

5-15

05

6

Max. Set Temp. 15-45

35

7

Display Mode

00

display both set temp. and room temp.

01

display set temp. only

00

8

High temperature

protection setting.

25-70

.

45

9

Installing your thermostat

Your thermostat is suitable for installation within 

a standard 86mm pattress box or European 60mm 

round pattress box.

Step 1. Keep power off. See Fig 1.

Fig 1

Step 2. Remove the mounting Plate. See Fig 2. 

Fig 2

Fig 3

Step 3. Connect power supply, load and external (floor) sensor 

into the appropriate terminals if there is external sensor. 

(see “Wiring your thermostat” for details and Fig 3).

Step 4. Fix the mounting plate into the wall with screws in 

the box. See Fig 4

    

Fig 4

Step 5. Fasten body of thermostat and the mounting plate 

through the groove. See Fig 5.

Fig 5

Step 6. Installation complete. See Fig 6.

Fig 6

RISK OF ELECTRICAL SHOCK.

 Disconnect/isolate 

power supply prior to making electrical connections. 

Contact with high voltage components can cause electrical 

shock, severe injury or death.

Default settings above assume a 5+2 (day) weekly 

program. 

Deadzone 

temperature

1-5

IN

Internal Sensor

to control or limit the temperature

AL

Ou: Only external sensor
AL: Internal/ External Sensor ( Internal sensor tocontrol the temp., 

external sensor to limit the temp.) .

Sensor types

IP Setting                0X01-0XFF

01

will show in the bottom left of the screen.

Touch and hold the icon    until the weekday 

schedule settings appear (1 2 3 4 5 will show 

along the top of the screen).

Use the       and      arrows to adjust the time for 

the 1st (Comfort) period

Press the icon    and use the      and      arrows 

to set the temperature for the 1st period. 

Repeat this process for periods 2 – 4. 

Press the icon   once more to enter the 

weekend schedule settings (6 & 7 will show along 

the top of the screen). 

Repeat the above process to set the weekend 

schedule. Press    once more to confirm and exit.

Default settings for program schedule

Time display

WEEKDAY (MON. – FRI.)

WEEKEND (SAT. – SUN.)

TIME

TEMP.

TIME

TEMP.

Period 1 (Comfort)

08:00 waken

27°C

Period 2 (Economy)

°C

Period 3 (Comfort)

13.30 home

Period 4 (Economy)

°

26  C

23°C

12:00 Leave

20  C

°

18:00 Leave

08:00 Waken

12:00 Leave
13:30 home

18:00 Leave

L1

N1

LOAD

IP20

N

L

1

2

3

4

NTC/10K

5
6

GB

 

AC95~240V

RS485+

(Red)

RS485-

(White)

10k NTC* - Compatible sensors 

tested and approved by Orcomm

10K NTC* - Compatible sensors tested and approved 

by Orcomm

ORC-HC2-16A-RS485-WH

8003/5331

A

Device Program Version Number.

402