Instruction Manual OXY-

 

SMART

 

 

 

 

 

 

3

 

1. 

Preface

 

 

Correct formatting is imperatively required for quality assurance when welding  
high-alloy, corrosion-resistant components. 
Only at very low residual oxygen content during the welding process 
it is possible to attain neat and corrosion-resistant welding seams with little colouring 
on the inner surface of the tube.  

An  insufficient  gas  protection  results  in 
annealing colouring or carburization in the 
heat  affected  zone  as  well  as  a  reduction 
of  the  corrosion  resistance  of  the  welding 
seam and thus it is unsuitable for any tube 
installation.  
To  monitor  the  quality  of  the  flushing  gas 
before the welding process, it is necessary 
to  use  measuring  devices  to  check  the 
residual oxygen content.  

 

The  welder  or  the  operator  can  use  the 
measuring  device  Oxy-

SMART

  to  check 

and  document  the  residual  oxygen 
content.  The  ppm  value  to  be  entered  in 
the  display  can  be  freely  selected.  If  not 
otherwise  imperatively prescribed, a value 
of  <  30  ppm  is  generally  sufficient  at  the 
beginning  of  the  welding  process.  If  the 
measured  value  falls  below  the  entered 
value,  the  colour  on  the  display  changes 
from red to green. 

 
It is possible to start the welding process. 
 
The mobile measuring device Oxy-

SMART

 

serves  to  record  the  residual  oxygen 
content  in  flushing,  welding  and  forming 
gases in the welding technique.  
Residual  oxygen  concentration  can  be 
measured and determined in the following 
gas  mixtures:  Inert  gases  and  forming 
gases.  Inert  gases  are  among  others 
nitrogen,  argon,  helium  and  other  rare 

gases.  Forming  gases  are  gas  mixtures  consisting  of  nitrogen  or  argon  and 
hydrogen. There are different gas mixtures with different H2 fractions, the maximum 
fraction of hydrogen must not exceed 10 %. 
The measuring device is not suitable to perform measurements of explosive gas 
mixtures, in particular it is not suitable to measure pure hydrogen. There is a risk of 
explosion!

 

 

Содержание OXY- SMART

Страница 1: ...nstruction Manual OXY SMART 1 OXY SMART ORBITEC GmbH Willi Brehm Straße 8 D 63500 Seligenstadt Phone 49 0 6182 78693 0 Fax 49 0 6182 78693 10 E Mail info orbitec group com Internet www orbitec group com ...

Страница 2: ...3 1 Front view 5 3 2 Top view 6 3 3 Lateral view 6 3 4 Rear view 7 4 Explanation of icons 8 5 Commissioning Operation 9 6 Measuring gases containing H2 13 7 Monitoring ranges Programming functions 14 8 Charging process 15 9 Filter status 17 10 Technical data 18 11 Servicing and maintenance 19 ...

Страница 3: ...ent The ppm value to be entered in the display can be freely selected If not otherwise imperatively prescribed a value of 30 ppm is generally sufficient at the beginning of the welding process If the measured value falls below the entered value the colour on the display changes from red to green It is possible to start the welding process The mobile measuring device Oxy SMART serves to record the ...

Страница 4: ...or and of the internal measuring gas pump The measuring device is not suitable to monitor the ambient air and must not be used to protect people No measuring without filter no warranty claim Only use original filters made by ORBITEC Caution when working in an environment with organic vapours such as e g scorching of plastic materials Such vapours might result in the sensor destruction Never open t...

Страница 5: ...Instruction Manual OXY SMART 5 3 General structure 3 1 Front view Filter Measuring gas hose Display Measuring gas inlet Keyboard ...

Страница 6: ...ction Manual OXY SMART 6 3 2 Top view 3 3 Lateral view Charging socket Measuring gas outlet Measuring gas inlet Hose connection Lanyard eyelet Wedge shaped structure hence ergonomic well readable and operable ...

Страница 7: ...Instruction Manual OXY SMART 7 3 4 Rear view Protective rubber frame Anti skid rubber feet Type plate Ergonomically shaped housing Calibrates seals ...

Страница 8: ...e measuring gas pump on and off ON OFF Switching the measuring device on and off P Programming button for monitoring range and setting Plus Up Menu navigation Increasing the selected values H2 Changing the gas type Inert H2 Battery Battery charge status indicator Pump when the pump is activated the turbine turns Inert H2 display the currently selected measuring gas is displayed ...

Страница 9: ... correct measuring process During this time it is not possible to perform any measurements In the standby mode the cell is heated up to 50 Structure of the measuring equipment Recommended structure Since most of purge gases are heavier than air it is recommended to connect the gas inlet at the lowest point of the system or the piping to expel the air and the residual oxygen effectively Oxy SMART W...

Страница 10: ... SMART 10 Never obstruct the gas outlet hole at the measuring point with the tube the flushing gas must always outflow freely The pump installed in the device must be allowed to suck in the flushing gas without overpressure ...

Страница 11: ... on the pump of the Oxy SMART Then the sensor is heated up up to 100 Measurement can be started as soon as the sensor is heated up Battery charge status Pump is turning Heating up phase Gas type Preset gas value of the release 30ppm factory setting Measured value 999ppm O2 ...

Страница 12: ...ressed and the measured value is more and more reduced After falling below the preset limit value in this case 30ppm the colour of the display changes from red to green Take the tube out of the gas outlet hole switch off the pump The Oxy SMART switches over to the standby mode it is possible to start the welding process ...

Страница 13: ...with gases containing hydrogen residues of gas remain in the surfaces of the ducting and in the filter material over an extended period of time If after the operation with forming gas inert gas is measured such as e g nitrogen or argon the measuring display will reach 0 ppm more rapidly than usual In such a case the device should be flushed with air for about 30min in order to achieve again reprod...

Страница 14: ...play illumination is dimmed Auto Off the Oxy is completely switched off Info Information to be viewed Year of construction serial number last calibration next calibration and operating hour counter Scroll the menu items with the navigation buttons and select with the button P Change the desired value with the navigation buttons and confirm with the P The menu item 01 Release can also be directly s...

Страница 15: ...ply unit included in the delivery for charging It is best suitable for worldwide use thanks to the different replaceable plugs Insert the plug of the power supply unit into the charging socket of the Oxy The batteries are charged the charging process is indicated on the display The battery is charged up to 100 after about 3h charging time The battery is charged It is not possible to overcharge it ...

Страница 16: ...rature the batteries Please switch off the unit and let it cool to room temperature Lithium ion batteries should only be charged in temperatures between 0 C and 50 C So This message also appears when the batteries are too cold for charging the Oxy SMART let acclimate Please switch off the unit and warm to room temperature This message indicates a defect in the battery Please send the device in for...

Страница 17: ...ilter capacity use wear and indicates the result by means of an error message on the display In case of such a warning please replace the filter and examine if the tube or the hose kit are damaged or if foreign particles have been sucked in In case of doubt replace the whole hose set incl the tube Please only use the filters prescribed by ORBITEC GmbH Designation Item No Illustration Complete hose...

Страница 18: ...s L x W x H 160 mm x 80 mm x 35 mm Weight incl hose kit 350 g Supply voltage 12 V Charging cable 100 240 V incl different adapters for worldwide use 9 h operating time by lithium ion technology 30 h standby time 3 h charging time Scope of delivery Measuring device for residual oxygen Charging cable incl different adapters Hose kit 1 m incl filter and tube Calibration certificate Plastic box with i...

Страница 19: ... aggressive cleaning agents Clean the housing with a dry cloth Liquids must not penetrate inside the housing e g through the charging socket or the measuring gas outlet The oxygen measuring device and the accessories were manufactured and tested based on permanent quality assurance according to DIN EN ISO 9001 Check accuracy and functioning of the measuring equipment at regular intervals of 12 mon...

Отзывы: