Ins
talling the Hand Sho

w

er

Hand Shower installation completed.

Содержание Oas Indo

Страница 1: ...Oas Indo Manual Oas Indo EU INSTALLATION 190923 INSTALLATION ...

Страница 2: ...receive the following certifications KIWA TG 1503 KIWA K100686 01 IAPMO E10059 IAPMO C 11154 IAPMO W 11301 Signed for and on behalf of Orbital Systems AB Place Date Name Position Malmö 2019 08 28 Mehrdad Mahdjoubi CEO Introduction Safety Messages This manual applies to model OS8732 Ei2 Thank you for purchasing the Oas shower system To enjoy the full potential of the shower please read and follow t...

Страница 3: ... installation or a faulty repair Repairs should be carried out only by Orbital Systems one of our certified service partners or the customer only when certified For showers outside of the warranty period spare parts are available for purchase directly from Orbital Systems or through one of our certified partners SAF ET Y I NSTRUCTIONS The appliance shall be supplied by a switch that provide a full...

Страница 4: ... 50 Orbital Systems and our team of expert staff including our certified Service Partners are available to assist you should you require product advice experience any problems need to purchase spare parts or to set up a service visit We recommend your first point of contact should be your installer who will be able to offer all of the above services Alternatively you can also contact Orbital Syste...

Страница 5: ...6 46 INSTALLATION OVERVIEW ...

Страница 6: ...7 46 147 7 1000 mm Installation Overview P RODUCT MEASUREMENTS 2190 mm 575 mm 184 mm 122 mm 145 mm Ø 75 mm 932 mm 600 mm 145 mm 1266 mm 812 mm 440 mm ...

Страница 7: ...on WiFi 2 4 GHz required Circuit breaker One per shower required Plumbing Water Hot and Cold Water Inlet Separate hot cold inlet required 1 2 BSPP G pipe connection needed Temperature of inlet water Cold 4 C to 30 C Hot 40 C to 65 C Water inlet flow Min 9 litres minute hot and cold Water pressure Min 3 bars 43 5 psi 0 3 MPa measured at the highest point of installation Max pressure 10 bars 145 psi...

Страница 8: ...to drain Ø75 mm Cold and hot water supply Recommended Min 9 litres minute Recommended Min 3 bar maximum 10 bar Electrical supply power 230 V 16 A INSTAL L AT ION OVERVIEW Installation Overview Core Wall Enclosure HxWxD 932 x 538 x 145 mm Min 2 600 mm 575 mm 2190 mm ...

Страница 9: ... Installation Overview RE CYC L ING OPTIMISATION SITE SUGGESTIONS Based on 8 minutes shower 7 minutes recycling in shower space with underfloor heating Fully enclosed shower space Recommended installation by Orbital Systems ...

Страница 10: ...11 46 INSTALLING THE SHOWER UNI T watch video https bit ly 2QNFVLP ...

Страница 11: ...7 18 Hose Connection Indo Core Indo Panel Panel Lock Magnetic Key Funnel Smart Sensor Unit Sensor Tank Sensor Cable Recirculation Hose Flush Hose Smart Sensor Lock half thread M4 3 Hex x1 full thread M4 3 Hex x1 WiFi Cable and Antenna Air Gap Tank Quartz Glass UV Lamp Filter Capsule Cleaning tablet Control Dial Installing the Shower Unit ...

Страница 12: ...13 46 Installing the Shower Unit ...

Страница 13: ...14 46 Install Sensor Cable Flush Hose and Recirculation Hose Make sure the sensor cable goes first Installing the Shower Unit Remove Panel Template and nuts ...

Страница 14: ...15 46 Pull the Sensor cable out to where the contact almost reaches the end of the sensor tank Apply lubricant Connect hoses to the Sensor Lock Installing the Shower Unit ...

Страница 15: ...16 46 Installing the Shower Unit x1 Half thread M4 3 Hex CAUTION If Sensor Lock is misaligned it can cause issues in further installation steps ...

Страница 16: ...e Rotate until parallel with drain bowl bottom Insert Smart Sensor Unit Cable through hole in Sensor Tank and connect with Sensor Cable Installing the Shower Unit x1 Full thread M4 3 Hex CAUTION Hand tighten cable connectors to avoid damage CAUTION Make sure the Smart Sensor Unit is inserted horisontally Do not angle the Smart Sensor CAUTION Make sure to have correct alignment between key and slot...

Страница 17: ...wall of the drain to avoid damage CAUTION Make sure Smart Sensor Unit is inserted correctly The O ring should not be visible Insert Sensor Tank and connect Smart Sensor Unit with Sensor Lock Make sure Sensor Lock is in Open position Set Sensor Lock to Locked position ...

Страница 18: ...19 46 Remove transport plugs before installation Installing the Shower Unit ...

Страница 19: ...that hoses and cables are not pinched Insert Core into Core Wall Enclosure and attach safety wire Keep tilted to enable electrical installation WARNING Electrical installation should be performed according to local regulations by a licensed electrician ...

Страница 20: ...21 46 x1 M8 Socket Head Installing the Shower Unit CAUTION Make sure to have correct alignment between key and slot in connectors ...

Страница 21: ...22 46 Installing the Shower Unit Provided by customer CAUTION Install hose connections according to local regulations and adaptations ...

Страница 22: ...23 46 Mount Indo Panel x8 M3 5 5mm driver Check Air gap placement Installing the Shower Unit ...

Страница 23: ...24 46 Make sure the gasket is placed in the circular groove x3 M4 Hex Socket Head 2 5 mm CAUTION Risk of damage to panel door if overtightening Installing the Shower Unit ...

Страница 24: ...25 46 CAUTION Make sure to have correct alignment between key and slot in connectors Adjust Indo Panel angle Installing the Shower Unit ...

Страница 25: ...26 46 Adjust x4 M3 5 5mm driver Secure Clean surface before attaching bracket Installing the Shower Unit ...

Страница 26: ...27 46 Adjust until edge aligned to edge Adjust until edge aligned with magnet Installing the Shower Unit ...

Страница 27: ...28 46 Adjust Indo Panel depth Installing the Shower Unit ...

Страница 28: ...ert Filter Capsule as instructed in the chapter Changing the Filter WiFi Setup For support in WiFi setup please contact support orbital systems com Europe CET 46 0 40 619 55 50 Insert Quartz Glass as instructed in the second half of the chapter Cleaning the Quartz Glass Insert UV Lamp as instructed in the second half of the chapter Changing the UV Lamp 79 82 83 85 77 78 67 68 ...

Страница 29: ...30 46 INSTALLING THE SHOWER H E AD ...

Страница 30: ...31 46 3 2 1 1 2 3 COMPONENT OVERVIEW Installing the Shower Head Shower Head Wall Mount Shower Head Arm Shower Head ...

Страница 31: ...32 46 2 mm It is recommended to cut the Wall box UNI Push with the LK Wall Box Cutter UNI Installing the Shower Head Cover both ends of the Shower Water Connector with thread sealant to avoid leakage ...

Страница 32: ...6 CAUTION Screw the Shower Head Wall Mount flush to the wall or leakage may occur Installing the Shower Head Shower Head installation completed CAUTION Apply lubricant to PEX hose inside of Shower Head Arm ...

Страница 33: ...34 46 INSTALLING THE HAND HEAD DI VE RTE R ...

Страница 34: ...se Diverter wall plate Diverter knob MC6S M4x8H A2 hexagon screw x3 Diverter housing cover T25 Screw 32mm 4 8mm T25 Screw 50mm 5 5mm Drilling template T8 2 5x8mm screw Torx T8 L key tool 3 9 10 4 4 5 COMPONENT OVERVIEW Installing the Hand Head Diverter 8 ...

Страница 35: ... mm holes in marked locations CAUTION Only drill through the tile itself no deeper Installing the Hand Head Diverter 18 mm x1 T25 Screw 50 mm x1 T25 Screw 32 mm CAUTION It s important that the PEX hoses are pushed in all the way to stop before cutting Seal holes according to local regulations Flip this template in case of left side orientation installation ...

Страница 36: ...37 46 Installing the Hand Head Diverter Hand Head Diverter installation completed x1 MC6S M4x8H A2 hexagon screw x2 MC6S M4x8H A2 hexagon screw x1 T8 2 5x8mm screw Use Torx T8 L key tool in kit ...

Страница 37: ...38 46 INSTALLING THE HAND SHOWER HOLDE R ...

Страница 38: ...39 46 1 2 3 4 5 Hand shower cover T25 Screw 50mm 5 5mm Hand shower bracket T25 Screw 32mm 4 8mm M4x8 Set screw 3 2 1 5 4 COMPONENT OVERVIEW Installing the Hand Shower Holder ...

Страница 39: ...46 Push Hand shower cover into position use Set screw to lock Installing the Hand Shower Holder Hand Shower Holder installation completed x1 T25 Screw 50 mm x1 T25 Screw 32 mm Use Torx T8 L key tool in kit ...

Страница 40: ...41 46 INSTALLING THE HAND SHOWE R ...

Страница 41: ...42 46 1 2 3 1 2 3 Hand Shower Shower Hose Sealing Ring COMPONENT OVERVIEW Installing the Hand Shower ...

Страница 42: ...43 46 Installing the Hand Shower Hand Shower installation completed ...

Страница 43: ...44 46 CONNECT OAS TO INTERNET ...

Страница 44: ...ower WIFI Settings Support Log out 12 00 ORBITAL SYSTEMS Settings Add Shower WIFI Settings Support Log out Connect OAS to Internet DOWNLOAD APP Download the Orbital systems iOS app from Apple app store and create an User account It is recommended to always use the latest available version Click Add shower and follow instructions SETUP WI F I ADD SHOWE R ...

Страница 45: ...C E R T I F I E D S PA C E T E C H N O L O G Y ...