Deluxe

“ODH” Series

4” & 6” Termination (duct)
Rough Opening:
11-1/4” L X 10-1/2” W
Housing Dimension:
11-1/4” L X 10-1/2” W X 7-5/8” H

Carefully position fan

for shortest duct run and 

fewest elbows to achieve

maximum performance

1.  Remove grille from housing before installation.
2.  Insert pair of sliding brackets in each bracket mount.
3.  Locate housing between ceiling joists and truss so bottom
     flange will fit flush to the ceiling joist.
4.  Loosely screw to joist through the mounting bracket 
     KEYHOLE slots (screws not provided).
5.  Optional side mount to ceiling joist and use one side of the 
      bracket for more stable support.

1.  For new fan installation position the housing in the
     attic next to the ceiling joist or truss.
2.  Trace housing bottom edge on ceiling material for cutout.
3.  Confirm the opening, then cut hole 11-1/4” X 10-1/2” of the
     housing inside edge.
4.  Place housing inside opening (attic) of the ceiling.
5.  To attach follow steps 3, 4, 5 for New Construction.

HUMIDITY SENSOR OPERATION

The humidity sensing fan uses a  sophisticated humidity  sensor that responds to: (a) rapid to moderate (user adjustable) 
increases in humidity or (b) humidity above a user adjustable set point (50%-100% relative humidity). The humidity sensor
may occasionally  turn the fan ON when environmental  conditions change. If the  fan continuously  responds to changing 
environmental  conditions, adjustment  “H” (humidity)  may be required. The fan  is factory set  for about 75%  (ambient 
temperature of 77  F).

OPERATION

o

2

Deluxe

“ODH” Series

SENSITIVITY ADJUSTMENT

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness 
H “+” may need to adjust to maximum setting. If the control is responding too often to changing environmental conditions, 
adjust H “-” to lower the setting. 
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns ON.
5. Repeat above steps if necessary.
Humidity sensor has a deviation values when the temperature changes.

TIMER ADJUSTMENT (For model OD80H OD110H OD80LH OD110LH OD80LLH and OD110LLH )

The humidity sensing fan has a timer “T” that can be adjusted from 5 to 60 minutes (factory setting is 20 minutes). This “T”
controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity and the humidity 
level is below the user adjusted set point. 
To adjust Timer “T”:
1. Disconnect power at service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” and adjust to desired setting (from 5 to 60 minutes).
4. Check by turning ON the Humidity switch until the fan turn ON.
5. Turn the Humidity Switch OFF and time the unit.

The control box, located inside the fan housing, has three separate adjustments: 
(1) The Low Airflow Knob adjusts the airflow from 30CFM up to the air flow rate of 
     the high fan speed determined by the dip switch setting.  
(2) The Humidity Sensor Knob set user adjustable setpoint.  
(3) The Dip Switch will adjust the fan speed setting from 80 to 120 CFM using a 
     4" duct or 90 to 140 CFM using a 6" duct.  
Note: Both 4" & 6" duct adaptors are included.

Fan run continuously at a low speed(adjustable by low airflow knob) and automatically 
boost up to high speed when humidity above a user adjustable setpoint 
(50%-100% relative humidity).
After delay timer (20 minutes) returns fan to the default low speed.

Model 

 

 

 

ODU814H ODU814LH ODU814LLH

-

+

-

+

1 2 3

1

Dip Switch

Power box

Low Airflow 

Knob

Humidity 

Sensor Knob

80 90 110 120 90 110 120 140

1

6"

Switch 

position

Duct 

diameter

(inches)

Airflow
(CFM)

6"

6"

6"

4"

4"

4"

4"

80 90 110 120 90 110 120 140

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 
position

Duct 

diameter
(inches)

Air deliver

(CFM)

6"

6"

6"

4"

4"

4"

4"

Other airflow reference performance based on HVI Procedures 
915, 916, and 920.

Factory setting: 110CFM (                    ) 
HVI Certified performance based on HVI Procedures 915, 916, 
and 920.

with 6" duct

2 3

2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

Dip Switch Position

* Blower Assembly includes part 6, 5, d, 4, c, b, a. 
Replacement installation:
Remove the screw (part c), then take out the motor plate (part 4) from the housing (part 9) by pushing 
down the rib in the plate while pulling out on the side of the housing. Replace the broken parts.

5

6

d

e

a

1a

2

3

4

b

c

1b

12

7

9

8

10

10

11

PART

PART NAME

Qty.

1b

2

3

4

5

6

7

8

9

10

11

12

a

b

c

d

e

Housing

Damper / Duct Connector

Lens

Wiring plate

Screw

Blower Wheel

Wire Panel / Harness Assembly

Motor

1

2

1

1

1

1

1

1

1

4

1

1

4

4

1

4

1

Isolator

Motor Plate

Washer

Nut, Hex Lock 

Grille Assembly (includes part 2)

1a

Grille Spring

Bar Hanger Kit

Screw

Power box

Model OD80H OD110H ODU814H 

Model OD80LH OD80LLH OD110LH 
OD110LLH ODU814LH ODU814LLH

SERVICE PARTS

WARNING: Power must be disconnected before servicing.