background image

Orbit Industries, Inc.   2100 S. Figueroa St.    Los Angeles, CA 90007     Tel: (213) 745-8884    Fax: (213) 745-2015   1-800-90-ORBIT

WARRANTY OWNER:

 Orbit Industries, Inc., warrants to the original consumer purchaser that 

it’s products will be free from defects in materials or workmanship for a period of one year from 
the date of original consumer purchase.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT 
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE.

During this one year period, Orbit, will at its option, repair or replace , without charge, any 
products or part which is found to be defective under normal use and service. 

THIS 

WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, 
FILTERS, DUCT, ROOF CAPS, and OTHER ACCESSORIES FOR DUCTING.

This warranty does not cover (a) normal maintenance and service or (b) any products or parts 
which have been subject to misuse, negligence, accident, improper maintenance of repair 
(other than by Orbit), faulty installation or installation contrary to recommended installation 

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
                     PERSON, OBSERVE THE FOLLOWING:

a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means 
    to prevent power from being switched on accidentally. When the service disconnecting means cannot be 
    locked, securely fasten a prominent warning device, such as a tag, to the service panel.

"CAUTION - For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors."

" Do Not Mount In A Ceiling Thermally Insulated To A Value Greater Than R40"

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
                     PERSON, OBSERVE THE FOLLOWING:

a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable 
    codes and standards, including fire-rated construction.
b) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
c) Ducted fans must always be vented to the outdoors.
d) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be 
    connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

WARNING:

a) "Do not  install fan  above or inside a 45-degree 
    angle projected outwards from the cooking equip-
    ment  element  closest to the fan. See instruction 
    sheet for clarification;" or
b) "Not  for use  in  cooking  area  -  see installation 
    instructions;" 

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*
(with built-in

*

 Purchase

damper)

separately

POWER
CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct
joints with

tape.

Keep duct
runs short

Recommended to put insulation around and the fan housing to 
minimize the  building heat loss. Seal  all the  gaps  around the 
housing with caulk or other similar material to inhibit air leakage
to the exterior of the thermal envelope of the building. Rigid sheet 
metal  duct  and the  shortest  path  to the  outside will minimize 
static pressure losses and promote adequate flow.

Deluxe

“ODH” Series

READ AND SAVE THESE INSTRUCTIONS

“WARNING - To Reduce The Risk Of Electric Shock, 
                        Do Not Use This Fan With Any Solid-State Speed Control Device.”

OD80H
OD80LH
OD80LLH
OD110H
OD110LH
OD110LLH
ODU814H
ODU814LH
ODU814LLH

1

INSTALL GRILLE

Install ceiling material to complete the ceiling construction. Then cut the opening 
around the fan housing.
Insert the sensor connector into the base connector in the unit and then install the 

Insert the light connector from the grille assembly into the base connector in the unit and then install the grille.
To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and 
position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly 
towards the ceiling to secure.

Removing Lens:

Carefully pryout the light lens by inserting a small, flathead screwdriver between the grille and lens.

Installing Light Bulbs:

Install the 23W, GU24 Flourescent lamp or 10W LED lamp and 4W Incandescent Lamp for Night Light.

Wire panel

Model OD80H  OD110H ODU814H 

Model OD80LH OD80LLH OD110LH OD110LLH ODU814LH ODU814LLH

ODU814H

FAN

WIRE

 PANEL

UNIT

BLACK (BLK)

SWITCH BOX

FAN

POWER SUPPLY

120V AC

GROUND (GRD)

WHITE(WHT)

FAN 

CONNECTOR

UNIT

BLACK (BLK)

NIGHT
LIGHT

LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

RED

WHITE (WHT)

BLUE (BLU)

FAN 

CONNECTOR

LIGHT

CONNECTOR

WIRE 

PANEL

ODU814LH

OD80H OD110H

WIRE

 PANEL

UNIT

BLACK(BLK)

SENSOR

SWITCH BOX

FAN

POWER SUPPLY

120V AC

GROUND (GRD)

BROWN(BRN)

WHITE(WHT)

FAN 

CONNECTOR

FAN

SWITCH BOX

HUMIDITY

HUMIDITY

HUMIDITY 

SENSOR

CONNECTOR

OD80LH OD110LH

UNIT

SENSOR

LIGHT

NIGHT
LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

BROWN (BRN)

FAN 

CONNECTOR

SENSOR

CONNECTOR

LIGHT

CONNECTOR

RED

BLACK (BLK)

WHITE (WHT)

BLUE (BLU)

Humidity

 

Sensor

UNIT

Motor

N

GRD

GRD

SWITCH

 

BOX

BLK

BLK

WHT

BLK

WHT

FAN

SWITCH

SENSOR
SWITCH

LINE

IN

COM

L

WHT

T

T

H

H

LIGHT

SWITCH

WHT

WHT

NIGHT

 

LIGHT

SWITCH

BLU

RED

LIGHT

NIGHT
LIGHT

BRN

FAN

WIRE 

PANEL

WIRING DIAGRAMS:

Deluxe

“ODH” Series

WIRING:  Power must be disconnected during installation.

1.  Run electrical as directly as possible from the wall switch to the unit.
2.  Using approved connectors, connect cables wires according to the model and diagram below to the junction box.
3.  Do not allow cable to touch side of unit after installation.

4

OD80LLH OD110LLH

UNIT

SENSOR

LIGHT

NIGHT
LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

BROWN (BRN)

FAN 

CONNECTOR

SENSOR

CONNECTOR

LIGHT

CONNECTOR

RED

BLACK (BLK)

WHITE (WHT)

BLUE (BLU)

Humidity

 

Sensor

UNIT

Motor

N

GRD

GRD

SWITCH

 

BOX

BLK

BLK

WHT

BLK

WHT

FAN

SWITCH

SENSOR
SWITCH

LINE

IN

COM

L

WHT

T

T

H

H

LIGHT

SWITCH

WHT

WHT

NIGHT

 

LIGHT

SWITCH

BLU

RED

LIGHT

NIGHT
LIGHT

BRN

FAN

WIRE 

PANEL

UNIT

BLACK (BLK)

NIGHT
LIGHT

LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

RED

WHITE (WHT)

BLUE (BLU)

FAN 

CONNECTOR

LIGHT

CONNECTOR

WIRE 

PANEL

ODU814LLH

VER 2

Отзывы: