Orbit Industries, Inc. 2100 S. Figueroa St. Los Angeles, CA 90007 Tel: (213) 745-8884 Fax: (213) 745-2015 1-800-90-ORBIT
WARRANTY OWNER:
Orbit Industries, Inc., warrants to the original consumer purchaser that
it’s products will be free from defects in materials or workmanship for a period of one year from
the date of original consumer purchase.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this one year period, Orbit, will at its option, repair or replace , without charge, any
products or part which is found to be defective under normal use and service.
THIS
WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES,
FILTERS, DUCT, ROOF CAPS, and OTHER ACCESSORIES FOR DUCTING.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts
which have been subject to misuse, negligence, accident, improper maintenance of repair
(other than by Orbit), faulty installation or installation contrary to recommended installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means
to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
"CAUTION - For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors."
" Do Not Mount In A Ceiling Thermally Insulated To A Value Greater Than R40"
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
b) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
c) Ducted fans must always be vented to the outdoors.
d) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING:
a) "Do not install fan above or inside a 45-degree
angle projected outwards from the cooking equip-
ment element closest to the fan. See instruction
sheet for clarification;" or
b) "Not for use in cooking area - see installation
instructions;"
ROOF CAP*
(with built-in
damper)
ROUND
DUCT*
WALL CAP*
(with built-in
*
Purchase
damper)
separately
POWER
CABLE*
INSULATION*
(Place around and
over Fan Housing.)
Seal gaps
around
Housing.
FAN
HOUSING
ROUND
ELBOW(S) *
Seal duct
joints with
tape.
Keep duct
runs short
Recommended to put insulation around and the fan housing to
minimize the building heat loss. Seal all the gaps around the
housing with caulk or other similar material to inhibit air leakage
to the exterior of the thermal envelope of the building. Rigid sheet
metal duct and the shortest path to the outside will minimize
static pressure losses and promote adequate flow.
Deluxe
“ODH” Series
READ AND SAVE THESE INSTRUCTIONS
“WARNING - To Reduce The Risk Of Electric Shock,
Do Not Use This Fan With Any Solid-State Speed Control Device.”
OD80H
OD80LH
OD80LLH
OD110H
OD110LH
OD110LLH
ODU814H
ODU814LH
ODU814LLH
1
INSTALL GRILLE
Install ceiling material to complete the ceiling construction. Then cut the opening
around the fan housing.
Insert the sensor connector into the base connector in the unit and then install the
Insert the light connector from the grille assembly into the base connector in the unit and then install the grille.
To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and
position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly
towards the ceiling to secure.
Removing Lens:
Carefully pryout the light lens by inserting a small, flathead screwdriver between the grille and lens.
Installing Light Bulbs:
Install the 23W, GU24 Flourescent lamp or 10W LED lamp and 4W Incandescent Lamp for Night Light.
Wire panel
Model OD80H OD110H ODU814H
Model OD80LH OD80LLH OD110LH OD110LLH ODU814LH ODU814LLH
ODU814H
FAN
WIRE
PANEL
UNIT
BLACK (BLK)
SWITCH BOX
FAN
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE(WHT)
FAN
CONNECTOR
UNIT
BLACK (BLK)
NIGHT
LIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
RED
WHITE (WHT)
BLUE (BLU)
FAN
CONNECTOR
LIGHT
CONNECTOR
WIRE
PANEL
ODU814LH
OD80H OD110H
WIRE
PANEL
UNIT
BLACK(BLK)
SENSOR
SWITCH BOX
FAN
POWER SUPPLY
120V AC
GROUND (GRD)
BROWN(BRN)
WHITE(WHT)
FAN
CONNECTOR
FAN
SWITCH BOX
HUMIDITY
HUMIDITY
HUMIDITY
SENSOR
CONNECTOR
OD80LH OD110LH
UNIT
SENSOR
LIGHT
NIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
BROWN (BRN)
FAN
CONNECTOR
SENSOR
CONNECTOR
LIGHT
CONNECTOR
RED
BLACK (BLK)
WHITE (WHT)
BLUE (BLU)
Humidity
Sensor
UNIT
Motor
N
GRD
GRD
SWITCH
BOX
BLK
BLK
WHT
BLK
WHT
FAN
SWITCH
SENSOR
SWITCH
LINE
IN
COM
L
WHT
T
T
H
H
LIGHT
SWITCH
WHT
WHT
NIGHT
LIGHT
SWITCH
BLU
RED
LIGHT
NIGHT
LIGHT
BRN
FAN
WIRE
PANEL
WIRING DIAGRAMS:
Deluxe
“ODH” Series
WIRING: Power must be disconnected during installation.
1. Run electrical as directly as possible from the wall switch to the unit.
2. Using approved connectors, connect cables wires according to the model and diagram below to the junction box.
3. Do not allow cable to touch side of unit after installation.
4
OD80LLH OD110LLH
UNIT
SENSOR
LIGHT
NIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
BROWN (BRN)
FAN
CONNECTOR
SENSOR
CONNECTOR
LIGHT
CONNECTOR
RED
BLACK (BLK)
WHITE (WHT)
BLUE (BLU)
Humidity
Sensor
UNIT
Motor
N
GRD
GRD
SWITCH
BOX
BLK
BLK
WHT
BLK
WHT
FAN
SWITCH
SENSOR
SWITCH
LINE
IN
COM
L
WHT
T
T
H
H
LIGHT
SWITCH
WHT
WHT
NIGHT
LIGHT
SWITCH
BLU
RED
LIGHT
NIGHT
LIGHT
BRN
FAN
WIRE
PANEL
UNIT
BLACK (BLK)
NIGHT
LIGHT
LIGHT
SWITCH BOX
FAN
120V AC LINE IN
GROUND (GRD)
RED
WHITE (WHT)
BLUE (BLU)
FAN
CONNECTOR
LIGHT
CONNECTOR
WIRE
PANEL
ODU814LLH
VER 2