Appendix C. Status Messages
4
Ocean TRx™ 4500 Installation and Operations Manual
Controller Screen Label
Description
WRN 154: PolSkew Communication Error
There was a checksum error or timeout on commands
received for the polarization skew axis.
WRN 155: PolSkew 96V out of range
Input 96V power is too high or low on the polarization
skew axis.
WRN 165: iNBR High LO Unlocked
The high local oscillator of the NBR is unlocked.
WRN 166: iNBR Low LO Unlocked
The low local oscillator of the NBR is unlocked.
WRN 167: Tracking Error Exceeds Limit
A tracking error has exceeded the predefined limit.
WRN 173: BUC Tx Stopped
BUC transmission has been stopped by the controller.
WRN 179: NBR Powr/Tempr out of tolerance
The NBR’s power supply/temperature has exceeded its
predefined tolerance levels.
WRN 180: No Noise Floor Table
The LNB noise floor level is not calibrated.
WRN 181: No Communication with BUC
There is no communication with the BUC.
WRN 182: Simulated AGC
The system is running a software simulation of AGC
rather than measuring real AGC from ACU input.
Error Messages
Controller screen label
Description
ERR 008: USB Ports not Detected; Reboot
USB bus initialization has failed. If shutdown is enabled
for this message, the system will reboot one minute after
startup.
ERR 009: System Reboots, Axes Jammed
The system will reboot because one or more of the axes is
jammed.
ERR 017: Restart Timed Out(Rebooting)
The system was not able to complete the restart routine in
the predefined time (normally set to 12 minutes).
ERR 022: CPU Power out of Tolerance
The CPU power supply has exceeded its predefined
tolerance levels.
ERR 023: CPU Temp out of Tolerance
The CPU temperature has exceeded its predefined
tolerance levels.
ERR 036: Servo Azimuth Config Init Error
The ACU could not compare or save the configuration file
in the azimuth servo driver.
ERR 038: Servo Elev Config Init Error
The ACU could not compare or save the configuration file
in the elevation servo driver.
ERR 040: Servo PolSkew Config Init Error
The ACU could not compare or save the configuration file
in the polarization skew servo driver.
ERR 042: Servo Tilt Config Init Error
The ACU could not compare or save the configuration file
in the tilt servo driver.
ERR 053: No Maintenance Config File
The ACU could not find the maintenance configuration file
in its flash memory (C:\) on power-up.
ERR 054: No Operational Config File
The ACU could not find the operational modes
configuration file in its flash memory (C:\) on power-up.
ERR 055: No Satellite Database File
The ACU could not find the satellite database file in its
flash memory (C:\) on power-up.
ERR 057: No System Configuration File
The ACU could not find the system parameters
configuration file in its flash memory (C:\) on power-up.