background image

MM.Inst.Ver.2.1.10

LIMITED WARRANTY

The warranty time on the mat products shall be 20 (Twenty) years from the time of delivery to the end user. Orbit

guarantees that the mats are free from defects in the material and workmanship. This guarantee is from Orbit and is
limited to the delivery of new products to the customer. Orbit or it’s distributors are under no circumstances liable for
consequential damages or losses including without limitation, the loss of profits arising from any cause whatsoever.
This guarantee is a material warranty only and does not cover field labor.

Please fill out the enclosed warranty card or register the warranty through our web site @ www.OrbitMfg.com.

On the line marked “conductor resistance” insert the resistance found in step 5 located in the Testing Procedure found
on page 3. If not registering electronically, please send the completed form to, Orbit Radiant Heating, Attn: Warranty
Department, 1507 B West Park Ave, Perkasie, PA 18944.

WARRANTY REGISTRATION MUST BE COMPLETED AND SUBMITTED TO THE MANUFACTURER OR

THE WARRANTY WILL BE NULL AND VOID.

Thermostat and Controls:

Always install the thermostat per local code. When using the floor

sensing thermostat, it is important to make sure that the floor sensor is placed 1-3’ out into the heated floor
and centered between two cable runs (See Diagram on Page 3). Where multiple mats are used, and the
amp load is greater than 15, an RFWCK Control Box is available.

Suggested Wiring To Be Performed By A Licensed Electrician In Accordance With All Applicable Local, State, & Federal Requirements.

4.

Metal, single gang

wall box

Ground

(Box must be grounded)

SENSOR

THERMOSTAT WIRING DIAGRAM

THERMOSTAT WIRING DIAGRAM

THERMOSTAT

120/240 LINE VOLTAGE, 15 AMP MAX. LOAD

120/240 LINE VOLTAGE, 15 AMP MAX. LOAD

IMPORTANT:

The

supply voltage used
for the Millimat
should be the same
voltage used for the
thermostat.

Millimat

Uninsulated, cold end

ground lead

Never cut any part of the Milimat
cable. Connection end contains
2 Clear insulated feed wires and

one uninsulated ground wire.

Shrink insulation bulb

MILLIMAT

AMPERAGE

DRAW MUST

NOT EXCEED 15

AMPS

(If the voltage of the mat is 120)

DO NOT MIX VOLTAGES

Consult Manufacturers

Instructions For Specific

Wiring Details.

(If the voltage of the mat is 208, 220, 230 or 240)

In Panel

In Panel

220, 230 or 240 Volt

Circuit Breaker

120 Volt

Circuit Breaker

To Floor Sensor
(Polarity is not important)

Bare copper wire

White wire

Black wire

To the neutral buss in the circuit breaker panel

Black or Clear

insulated wire

Power leads
for the thermostat

Power leads
for the thermostat

Power leads
for the thermostat

Circuit breaker

panel

Black wire

Red wire

CAUTION: Supply the

Millimat

with the voltage it is tagged

with at the factory.

NEVER CUT THE HEATING

CABLE