MM.Inst.Ver.2.1.10
LIMITED WARRANTY
The warranty time on the mat products shall be 20 (Twenty) years from the time of delivery to the end user. Orbit
guarantees that the mats are free from defects in the material and workmanship. This guarantee is from Orbit and is
limited to the delivery of new products to the customer. Orbit or it’s distributors are under no circumstances liable for
consequential damages or losses including without limitation, the loss of profits arising from any cause whatsoever.
This guarantee is a material warranty only and does not cover field labor.
Please fill out the enclosed warranty card or register the warranty through our web site @ www.OrbitMfg.com.
On the line marked “conductor resistance” insert the resistance found in step 5 located in the Testing Procedure found
on page 3. If not registering electronically, please send the completed form to, Orbit Radiant Heating, Attn: Warranty
Department, 1507 B West Park Ave, Perkasie, PA 18944.
WARRANTY REGISTRATION MUST BE COMPLETED AND SUBMITTED TO THE MANUFACTURER OR
THE WARRANTY WILL BE NULL AND VOID.
Thermostat and Controls:
Always install the thermostat per local code. When using the floor
sensing thermostat, it is important to make sure that the floor sensor is placed 1-3’ out into the heated floor
and centered between two cable runs (See Diagram on Page 3). Where multiple mats are used, and the
amp load is greater than 15, an RFWCK Control Box is available.
Suggested Wiring To Be Performed By A Licensed Electrician In Accordance With All Applicable Local, State, & Federal Requirements.
4.
Metal, single gang
wall box
Ground
(Box must be grounded)
SENSOR
THERMOSTAT WIRING DIAGRAM
THERMOSTAT WIRING DIAGRAM
THERMOSTAT
120/240 LINE VOLTAGE, 15 AMP MAX. LOAD
120/240 LINE VOLTAGE, 15 AMP MAX. LOAD
IMPORTANT:
The
supply voltage used
for the Millimat
should be the same
voltage used for the
thermostat.
Millimat
Uninsulated, cold end
ground lead
Never cut any part of the Milimat
cable. Connection end contains
2 Clear insulated feed wires and
one uninsulated ground wire.
Shrink insulation bulb
MILLIMAT
AMPERAGE
DRAW MUST
NOT EXCEED 15
AMPS
(If the voltage of the mat is 120)
DO NOT MIX VOLTAGES
Consult Manufacturers
Instructions For Specific
Wiring Details.
(If the voltage of the mat is 208, 220, 230 or 240)
In Panel
In Panel
220, 230 or 240 Volt
Circuit Breaker
120 Volt
Circuit Breaker
To Floor Sensor
(Polarity is not important)
Bare copper wire
White wire
Black wire
To the neutral buss in the circuit breaker panel
Black or Clear
insulated wire
Power leads
for the thermostat
Power leads
for the thermostat
Power leads
for the thermostat
Circuit breaker
panel
Black wire
Red wire
CAUTION: Supply the
Millimat
with the voltage it is tagged
with at the factory.
NEVER CUT THE HEATING
CABLE