![Orbit JETRONIC-BOX Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/orbit/jetronic-box/jetronic-box_manual_1647885012.webp)
Orbit JETRONIC-BOX – Manual 1.2
24:@AIR~FAIL
Specifies the failsafe function that is activated when the air pressure falls below the minimum value
specified with 14:AIR-FAIL.
Typically, the failsafe function activates an ON signal at RC1 (=> extend gear). On the display, this
is indicated by a -
!
at the RC1 or RC2 status.
OFF
:
No air pressure failsafe function
OFF
→
RC1
:
Input RC1 is switched to OFF.
ON
→
RC1
:
Input RC1 is switched to ON.
OFF
→
RC2
:
Input RC2 is switched to OFF.
ON
→
RC2
:
Input RC2 is switched to ON.
Default setting:
OFF
12