Orbit Industries, Inc.   2100 S. Figueroa St.    Los Angeles, CA 90007     Tel: (213) 745-8884    Fax: (213) 745-2015   1-800-90-ORBIT

WARRANTY OWNER:

 Orbit Industries, Inc., warrants to the original consumer purchaser that it’s products will be free from 

defects in materials or workmanship for a period of one year from the date of original consumer purchase.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During this one year period, Orbit, will at its option, repair or replace , without charge, any products or part which is found to be 
defective under normal use and service. 

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR 

TUBES, FILTERS, DUCT, ROOF CAPS, and OTHER ACCESSORIES FOR DUCTING.

This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to 
misuse, negligence, accident, improper maintenance of repair (other than by Orbit), faulty installation or installation contrary to 
recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the 
express warranty. Orbit 

OBLIGATION TO REPAIR OR REPLACE, AT Orbit OPTION, LIABLE FOR INCIDENTAL, 

CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR 
PERFORMANCE.

 Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusive may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which 
vary from state to state. This warranty supercedes all prior warranties.

WARRANTY SERVICE:

 To qualify for warranty service, you must (a) notify Orbit at the address stated below, (b) give the 

model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting 
warranty service, you must present evidence of the original purchase date.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
                     PERSON, OBSERVE THE FOLLOWING:

a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means 
    to prevent power from being switched on accidentally. When the service disconnecting means cannot be 
    locked, securely fasten a prominent warning device, such as a tag, to the service panel.

"CAUTION - For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors."

" Do Not Mount In A Ceiling Thermally Insulated To A Value Greater Than R40"

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
                     PERSON, OBSERVE THE FOLLOWING:

a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable 
    codes and standards, including fire-rated construction.
b) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
c) Ducted fans must always be vented to the outdoors.
d) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be 
    connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

WARNING:

a) "Do not  install fan  above or inside a 45-degree 
    angle projected outwards from the cooking equip-
    ment  element  closest to the fan. See instruction 
    sheet for clarification;" or
b) "Not  for use  in  cooking  area  -  see installation 
    instructions;" 

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*
(with built-in

*

 Purchase

damper)

separately

POWER
CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct
runs short

Recommended to put insulation around and the fan housing to 
minimize the  building heat loss. Seal  all the  gaps  around the 
housing with caulk or other similar material to inhibit air leakage
to the exterior of the thermal envelope of the building. Rigid sheet 
metal  duct  and the  shortest  path  to the  outside will minimize 
static pressure losses and promote adequate flow.

Deluxe

ODU814M

READ AND SAVE THESE INSTRUCTIONS

“WARNING - To Reduce The Risk Of Electric Shock, 
                        Do Not Use This Fan With Any Solid-State Speed Control Device.”