28
| INSTRUCTIONS FOR USE
OMD 202RS
SETTING
LIGHT
5.
DISPLA
YED ONL
Y WITH OPTIONS
> ANAL
OG OUTPUT
Typ. A.O
Setting the type of analog
output
Menu
Range
Description
0-20mA
0…20 mA
Er.4- T
4…20 mA
signaling interrupted current loop and displaying an error message
(< 3,0 mA)
4-20 T
4…20 mA
signaling broken current loop (< 3,0 mA)
Er.4-20mA
4…20 mA
with indication of error statement (< 3,0 mA)
4-20mA
4…20 mA
0-5mA
0…5 mA
0-2 V
0…2 V
0-5 V
0…5 V
0-10 V
0…10 V
+-10 V
±10 V
DEF
= 4…20 mA
MIN A.O.
Assigning the display value to
the beginning of the AO range
- range of the setting: -99999…999999
DEF
= 0
Items for “Limits” and “Analog output”
are accessible only if incorporated in the
instrument.
Display value for the beginning of the AO range > MIN A.O. = 0
Example
R
R
R
R
TYP. A.O.
Type of analog output - 0...10 V > TYP. A.O. = U 10
Example
4-20mA
0-2 V
0-5mA
0-10 V
0-5 V
MIN A.O.
0-20mA
Er.4- T
4-20 T
Er.4-20
0-10 V
+-10 V
0
Assigning the display
value to the beginning of
the AO range
0
MAX A.O.
MIN A.O.
• • •