20
INSTRUCTIONS FOR USE OM 651UC
4.3.3 CONFIGURATION MODE - OUTPUT
INPUT
SERVIC.
OUTPUT
CHANEL
LIMIT
A.OUT.
DATA
BRIGHT
LIMITA
Setting the functions
and type of limits switch-on
DATA
Setting the type and
parameters of data output
A. OUT.
Setting the type and
parameters of analog output
BRIGHT
Setting the display
brightness
4.3.3.1.1 LIMITS - SETTING THE RELAY MODE
INPUT
SERVIC.
OUTPUT
CHANEL
LIMIT
A. OUT
DATA
BRIGHT
LIM 1
LIM 2
TYPE
TIME
HYST.
LIMIT
CLOSE
OPEN
DEF
TYPE
Setting the relay
switching mode
CLOSE
The relay switches on when
the condition is met
OPEN
The relay switches off when
the condition is met
4.3.3.1.2 LIMITS - SETTING THE BOUNDARIES
INPUT
SERVIC.
OUTPUT
CHANEL
LIMIT
A. OUT.
DATA
BRIGHT
LIM 1
LIM 2
HYST
LIMIT
TIME
LIM -
Setting the values for
limits evaluation
LIMIT
Setting limit for relay
switch on
- in full display range
HYST
Setting hysteresis only in
(+) values
- in 1/10 of the display range
TIME
Setting the delay of the limit
switch-on
- in range 0…99,9 s