background image

 

 

 

 

 

 

 

SETTINGS 

CLOCK 

 LANGUAGE 

 ADVANCED 

 

 

 

 

 

 

      

BRIGHTNESS 

 

 

 

 

 

 

 

      

PERMANENT 

 

 

 

 

 

 

 

      

HOLIDAYS 

 

 

 

 

 

 

 

 

 

 

 

 

 

METERS 

 

 

 

 

 

 

 

      

SEASON 

 

 

 

 

 

 

 

      

PIN 

CODE 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 H / 24 H 

 

 

 

 

 

 

 

      

VERSION 

 

 
PROGRAMS.

 This is the menu where the different operations are programmed. There are 40 memory spaces 

(P-01 to P-40). 

 

 

ENTER.

 We enter by pressing 

, and with the 

 and 

 keys we move through the different programs 

stored in the memory.  
When entering this menu, if any programs have already been stored, the first program that was stored 
appears in the display text line: “P-01”, and with the 

 key we can go up the different stored programs until 

we reach the first empty program, in which the display text line will show “P-XX EMPTY” alternating with the 
number of programs available left in the memory of the device.  
When entering this menu, if no other programs have been created, the display text line will show: “P-01 
EMPTY” alternating with “40 LEFT” referring to the memory spaces available.  
If we wish to modify or create a program we move to it with the 

 and 

 keys, and press 

. Next, with the 

 and 

 keys we select one of the following options:  

o

  EDIT. This option allows us to choose the type of operation that will be performed in the selected 

program. By pressing 

, “ON TYPE” will be displayed and with the 

 and 

 keys we can choose the 

type of operation. The operations can be: 

-

  ON TYPE. Switch-on of the connected circuit at a fixed time. 

-

  OFF TYPE. Switch-off of the connected circuit at a fixed time.  

-

  CYCLE TYPE. ON and OFF operations performed repeatedly from beginning to end. To program the 

beginning of the cycle we have to indicate the hour, minutes, and days of the week when this cycle 
will begin. Next, we need to specify the respective ON and OFF duration (in hours, minutes or in 
seconds). To finish, we must indicate the hour, minutes, and days of the week when this cycle will 
stop operating.  

-

  PULSE TYPE. Switch-on of the circuit in a pulse of a set duration at a fixed time of the day.  

Once the type of operation has been chosen, we have to select the cannel or channels it affects (C1, C2 
or C1 + C2). 
Next, we enter the operation starting hours and the rest of the necessary times according to the selected 
operation.  

  

HOLIDAY PERIODS program  

If when validating the last day of the week with the 

 key we keep it pressed, we select this operation as 

holiday. The word HOLIDAY is displayed and with the 

 and 

 keys we select one of the 4 holiday 

periods.  

 

o

  DELETE. By pressing 

, the selected program is deleted. Since all programs are stored consecutively, 

deleting one program can change the number assigned to each one of them.  

 

 

DELETE. 

This option allows for deleting all the operations of the last 40 programs in just one step. 

 

 
We choose to perform the switch-on program at 10 pm  

 

 

 

 

 

 

 

 

 

 

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P01 

 

EDIT 

 

ON 

 

 

CHANNEL  

Hour and 

min 

 

Days of the 

week 

 

 

C1 and C2 

 

22:00 

 

Mon…Sun 

 

P01 OK 

 

 
We choose to perform the switch-off program at 12 am  

 

 

 

 

  

 

   

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P02 

 

EDIT 

 

OFF 

 

 

CHANNEL  

Hour and 

min 

 

Days of the 

week 

 

 

C1 and C2 

 

00:00 

 

Mon…Sun 

 

P02 OK 

 

 
We choose to perform the cycle program, with a 5-second ON and a 10-second OFF period, which will 
start at 6:00 and will finish at 8:00 during the entire week 

 

 

 

 

 

  

  

 TYPE  

MENU 

 

PROGRAMS 

 

ENTER 

 

P03 

 

EDIT 

 

CYCLE 

 

 

CHANNEL  

FROM 

Hour and 

min. 

 

Days of the 

week 

 

ON TIME 

Hour and 

min. 

 SECONDS  

C1 y C2 

 

06:00 

 

Mon…Sun 

 

00:00 

 

05 

 

 

OFF TIME 

Hour and 

min. 

 SECONDS  

UNTIL 

Hour and 

min. 

 

Days of the 

week 

 

 

00:00 

✓ 

10 

 

08:00 

 

Mon…Sun 

 

P03 OK 

 

 
We choose to perform the pulse program, which will perform a 5-second ON period starting at 11:30 
during the entire week 

 

 

 

 

  

 

 

 

 

TYPE 

 

MENU 

 

PROGRAMS 

 

ENTER 

 

P04 

 

EDIT 

 

PULSE 

 

 

CHANNEL  

Hour and 

min. 

 SECONDS  

Days of the 

week 

 

 

C1 and C2 

 

11:30 

 

05 

 

Mon…Sun 

 

P04 OK 

 

 
 
 
 
 
 
 
 
 

SETTINGS.

 This is the menu where we configure the device.  

 

 

CLOCK. 

Sets the time of the device. The variables to configure are (in this order): Year, month, day, hour 

and minute. The day of the week is calculated automatically. 

 

 

LANGUAGE.

 This is the menu where the language of the device is selected.  

 

ADVANCED. 

This is the menu where most of the device configuration can be done. 

 

o

  BRIGHTNESS. Menu where we can select the brightness of the display. MINIMUM, LOW, MEDIUM, 

HIGH, or MAXIMUM. The brightness on screen will be adjusted if we validate the visualised level.  

o

  PERMANENT. The menu where we can set a permanent operation (ON or OFF) of channel C1 and 

channel C2. With the 

 and 

keys we move through the different options: C1: YES 

 C1: NO 

 C2: 

YES 

 C2: NO. We validate with 3 our desired option. The device will not take notice of the operation 

programming for the selected channel if we choose the YES OPTION.  

o

  The contact position can be changed manually (see 

MANUAL OPERATION

o

  HOLIDAYS. It has 4 PERIODS that can be programmed to perform the operations selected in the 

programming of HOLIDAY PERIODS. If no operation is programmed in a period, the channels will 
remain OFF during said period. PERIOD 1 …4 

-

  EDIT. The month, day, hour and minute of the beginning of the period and the month, day, hour and 

minute of the end of the period are programmed. This period will be repeated year after year.  

-

  DELETE. The selected period is deleted.  

o

  METERS. Menu where the switch-on time of each circuit is indicated (in hours). Accessing the meter of 

each channel with 

, they can be set to zero. Select DELETE YES and validate.  

o

  SEASON. Allows for adjusting the time change from daylight saving to standard time and vice versa.  

-

  ACTIVE. Automatically makes the time change from daylight saving to standard time or vice versa, in 

accordance with each country’s legislation. (EU the last Sunday of March and the last Sunday of 
October) 

-

  INACTIVE. Does not make the time change.  

o

  PIN CODE. Menu to activate or disable the keyboard lock to prevent unwanted access to the device 

settings.  

-

  INACTIVE. Keyboard lock disabled.  

-

  ACTIVE. Keyboard lock activated. And we are required to program a four-figure PIN CODE. This 

protection will be activated 30 seconds after we come out of the settings and return to the display in 
standby mode. From that moment on when any key is pressed the message “PIN CODE” will appear 
on screen. To unblock the access to the device, we will need to enter the PIN CODE programmed in 
its activation. The device will be unblocked for 10 seconds. During this time we will be able to access 
the settings menu by pressing 3. After 30 seconds without handling the device, it will get locked again.  

o

  12H – 24H. With the 

 and 

keys we select the mode in which we wish to see the time. We validate 

the selection with 

 

o

  VERSION. Menu where the software version of the device is shown.  

 

If simultaneous operations are programmed we have to take into account that some have priority over the 
others. The priority order is as follows:  

PERMANENT MODE 

 MANUAL 

 PROG_01 

 PROG_02 

 …. 

 PROG_40 

 

RESET. SET TO ZERO.  

Starting on standby mode (main screen), press the 

C

 key and while keeping it pressed press the 

 and 

 

keys simultaneously for more than 3 seconds. The display gets turned off, all programming is deleted. The 
device must be powered.  
We can also perform a quick deletion that does not affect the programming by pressing the four keys 
simultaneously. The device must be powered.  

 

BATTERY CHANGE. FIG. 4 

The device has a power-reserve of 4 years, by means of a replaceable CR2032 lithium battery. Battery 
replacement is made by removing the battery holder placed on the front of the device through a flat-head 
screwdriver. Observe the battery polarity as marked on the battery holder. 
When the battery is dead and the device is powered the battery symbol appears on screen.  
NOTE: When changing the battery the device’s programming is not lost, and neither is the current time. 

TURN OFF THE POWER SUPPLY TO REPLACE THE BATTERY 

 

PROGRAMMING VIA SMARTPHONE/TABLET 

It incorporates a bluetooth system 4.0 LE for the communication with an application installed on a portable 
smart device (Apple or Android) Bluetooth Smart Ready compatible. 

-

  Apple (iPhone 4S or higher, IPad 3 or higher) 

-

  Android (version 4.3 or higher and device compatible with Bluetooth 4.0 LE) 

 
To communicate with Data Log or Data Log 2 is needed to have the application ORBIS DATA LOG installed. 
 
This App allows the following functions: 

  To read the data of a device to store them or to send them to another device 

  To create different profiles (configurations) from beginning or from an already existing profile of other device 

  To send a profile to one or several device  

  To see performance statistics (monthly and yearly number of ON-hours). 

 
To start using the App follows the next steps: 

1. 

Download the App from AppStore or PlayStore, making sure your device is compatible with technology 
Bluetooth Smart Ready. 

2. 

Start the App and select the option “Connect with the device” 

 

to read the data (configuration) of the 

device. 

3. 

Check and/or modify the received data and store 

 

the profile for a future use and/or send again the 

modified profile to the device  . 

4. 

Close the App and disconnect the bluetooth from device for a normal function of the device. 

 
TECHNICAL FEATURES 

Rated voltage and frequency  

As indicated in the device 

Resistance  

± 10% 

Breaking capacity: 

DATA LOG BT: µ 16 (10) A / 250 V~ 
DATA LOG 2 BT: µ 2x16 (10) A / 250 V~

 

Maximum recommended loads (N.A): 

FIG.3

 

Own consumption 

16 VA (1.3 W) maximum 

Contact AgSnO

2

  switched.   

Display screen  

Back-lit LCD 

Running accuracy 

± 1 s / day at 23 ºC 

Accuracy variation with temperature 

± 0.15 s / ºC / 24 h 

Power reserve 

4 years (with battery and no network connection) 

 

48 h (no battery and no network connection) 

Type of action 

1S, 1T, 1U  

Software class and structure 

Class A 

Memory spaces 

40 

No. of channels 

1 channel DATA LOG BT; 2 channels DATA LOG 2 BT 

Types of operations 

ON/OFF, PULSE (1 to 59 sec.) and CYCLES (1 to 59 sec. or 1 
min to 23h and 59 min). 

Astronomical adjustments  

± 1 second 

Operating temperature  

-10 ºC at +45 ºC 

Transport and storage temperature 

-20 ºC at +60 ºC 

Pollution situation 

Protection level  

IP20 according to EN60529 

Protection class 

II under correct mounting conditions 

Transient impulse voltage 

2.5 kV 

Temperature for the ball test 

+ 80 ºC for 21.2.5 

Keyboard access cover 

Sealable 

Connection 

With screw terminal for wire cross section of up to 4mm² 

Battery 

CR2032 – 3 V – 220 mAh 

Wrapping size 

2 DIN modules (35 mm) 

FIG.5

 

 

WARNING: 

This time switch includes a battery whose contents may be damaging to the environment. Do not get rid of the 
product without taking the precaution of dismantling the battery and placing it in an appropriate recycling 
container, or sending the product back to the factory.   

 

Hereby, ORBIS TECNOLOGÍA ELÉCTRICA, S.A. declares that the radio equipment type DATA LOG BT / 
DATA LOG 2 BT is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity 
is available at the following internet address: http://www.orbis.es/downloads/declarations-of-conformity 

 

Subject to technical changes – for further information: www.orbis.es 

 
 
 

Содержание DATA LOG BT

Страница 1: ...UANDO EL EQUIPO ESTÉ TOTALMENTE INSTALADO MONTAJE Dispositivo de control electrónico de montaje Independiente en armario de distribución con perfil simétrico de 35 mm según norma EN 60715 Rail DIN CONEXIÓN Conectar la alimentación según el esquema de la FIG 2 Es necesario respetar la posición de Fase y Neutro comprobando las conexiones realizadas Una conexión equivocada puede destruir el aparato P...

Страница 2: ... verano a invierno o viceversa ACTIVO Realiza automáticamente el cambio horario verano invierno según la legislación de cada país UE el último domingo de marzo y el último domingo de octubre INACTIVO No realiza el cambio de horario CODIGO PIN Menú para la activación o desactivación del bloqueo del teclado para impedir el acceso no deseado a la configuración del aparato INACTIVO Bloqueo del teclado...

Страница 3: ...FULLY INSTALLED MOUNTING Electronic control device of independent mounting in fuse box with 35 mm symmetrical profile according to EN 60715 standard DIN Rail CONNECTION Connect power supply according to the diagram in FIG 2 Phase and Neutral positions must be respected checking the connections made A wrong connection may destroy the device START UP THE DEVICE MUST BE POWERED to be able to execute ...

Страница 4: ...ime and vice versa ACTIVE Automatically makes the time change from daylight saving to standard time or vice versa in accordance with each country s legislation EU the last Sunday of March and the last Sunday of October INACTIVE Does not make the time change o PIN CODE Menu to activate or disable the keyboard lock to prevent unwanted access to the device settings INACTIVE Keyboard lock disabled ACT...

Страница 5: ...rollo elettronico con montaggio indipendente in armadio di distribuzione con profilo simmetrico da 35 mm come da norma EN 60715 DIN CONNESSIONE Collegare il dispositivo secondo lo schema indicato in FIG 2 Rispettare la posizione di Fase e Neutro e verificare i collegamenti effettuati Un collegamento errato può comportare un guasto e conseguentemente un malfunzionamento del dispositivo MESSA IN FUN...

Страница 6: ...s lasso in cui si potrà accedere al menu di impostazione del dispositivo premendo o si potranno effettuare altre operazioni Se nell arco di 30 s non si agisce sul dispositivo il medesimo si bloccherà di nuovo 12 ore 24 ore Con i tasti e selezionare la modalità di visualizzazione dell ora Confermare con VERSIONE Menu indicante la versione del software del dispositivo In caso di programmazione di op...

Страница 7: ...spositif de contrôle électronique de montage Indépendant dans une armoire de distribution avec profil symétrique de 35 mm selon norme EN 60715 Rail DIN CONNEXION Connecter l alimentation selon le schéma de la FIG 2 Il est nécessaire de respecter la position de Phase et Neutre en vérifiant les connexions réalisées Une connexion erronée peut détruire l appareil MISE EN SERVICE Pour que le dispositif...

Страница 8: ... heure par le passage de l été à l hiver ou vice versa ACTIF Il réalise automatiquement le changement horaire été hiver selon la législation de chaque pays UE le dernier dimanche de mars et le dernier dimanche d octobre INACTIF Il ne réalise pas le changement d horaire CODE PIN Menu pour l activation ou désactivation du blocage du clavier pour empêcher l accès non souhaité à la configuration de l ...

Отзывы: