background image

 
 
 

CIRCUMAT 

 

1

Ø120

25

LUX

SENS

TIME

30

20

10

5

1

15s

3s

2

5

4

4

4

FIG.1

FIG.6

3

5

64

2,4 m

Ø7 m

N

L

N

L

N

200 VA

250 VA

1000 W

500 VA
1000 W

200 VA
200 VA

CFL

DOWNLIGHT

LED

FIG.2

FIG.5

FIG.3

FIG.4

 

 
 
02/02.2015  

        

 

 

                    A016.13.56422 

 
 
 
 
 

ESP 
 
 

DETECTOR DE MOVIMIENTO

 

 
INSTRUCCIONES DE EMPLEO 

 

FIG.1 

1. 

Tapa 

4. 

Selectores 

2.

 Bornas de conexión 

5.

 Taladros de fijación 

3.

 Sensor 

 
DESCRIPCIÓN 

El detector de movimiento CIRCUMAT capta las emisiones invisibles infrarrojas 
procedentes de personas y otras fuentes de calor sin emitir ningún tipo de radiación. 
Cuando una fuente de calor se mueve debajo del CIRCUMAT su circuito de salida se 
activa. Una vez que deja de captar el movimiento se desactiva tras un tiempo de retardo 
regulable. 
El detector de movimiento reacciona únicamente cuando las condiciones de luz están por 
debajo del nivel seleccionado. 
 

INSTALACIÓN 

ATENCIÓN: La instalación y el montaje de los aparatos eléctricos debe ser realizada por 
un instalador autorizado. 
ANTES DE PROCEDER A LA INSTALACIÓN DESCONECTE LA ALIMENTACIÓN. 
El aparato está internamente protegido contra las interferencias por un circuito de 
seguridad. No obstante, algunos campos electromagnéticos especialmente fuertes pueden 
llegar a alterar su funcionamiento, por tanto, no debe instalarse próximo a campos 
inductivos (motores, transformadores, centros de transformación, maquinaria industrial, 
etc.) o señales inalámbricas de alta frecuencia (WIFI, telefonía, inhibidores de señal. etc.) 

 

MONTAJE Y CONEXIÓN 

Sobre techo evitando que en su área de detección se encuentren superficies altamente 
reflectantes (líquidos, mármol, etc.), elementos sujetos a cambios bruscos de temperatura 
(calefacción, aire acondicionado, posibles corrientes de aire, etc.) o fuentes luminosas. 
En la instalación del CIRCUMAT se debe tener en cuenta que la activación se produce 
cuando la fuente de calor cruza sus haces de detección y, por lo tanto, si va en dirección al 
aparato, la detección es posible que se produzca a una menor distancia, ya que puede que no 
atraviese los haces, hasta que esté próximo al aparato. 
En el dibujo de la 

FIG.2

, las flechas indican la dirección del movimiento de la persona u 

objeto a detectar. 
El área de detección depende directamente de la altura de montaje, de acuerdo a la 

FIG.2

 
Retirar la tapa frontal como muestra el dibujo de 

FIG.3

. Fijar el equipo al techo a través de 

los taladros mediante dos tornillos incluidos. Realizar la conexión de los conductores 
mediante los bornes de tornillo. Conexionar de acuerdo al esquema de la 

FIG.4

.  

 
PUESTA EN SERVICIO 

Después de la conexión el aparato realiza una comprobación del sistema durante 
aproximadamente 60 segundos, transcurrido este tiempo está preparado para funcionar y 
realizar los ajustes seleccionados. 
Al quitar la tapa quedan al descubierto tres selectores para los diferentes ajustes que se 
pueden realizar en el funcionamiento del CIRCUMAT. 

FIG.5

 

 

INDICADORES DE DETECCIÓN 

Un led rojo indica el estado del CIRCUMAT de la siguiente manera: 

 Parpadeando: El detector de movimiento está en “STAND BY” esperando 

movimiento. 

  Apagado: Las condiciones de luminosidad están por encima de la programada. 

  Encendido: El equipo detecta movimiento. 

 
AJUSTE DEL CAMPO DE DETECCIÓN: 

La temperatura ambiente del recinto donde se instala el CIRCUMAT influye bastante en la 
sensibilidad de la detección y por tanto, en la distancia de detección. A mayor temperatura 
peor sensibilidad, ya que el aparato funciona por detección del movimiento de una fuente 
de calor (en la mayor parte de los casos 36 ºC temperatura del cuerpo humano), cuando 
más cercana a 36 ºC sea la temperatura ambiente peor es la detección. 
 
Para  ajustar el campo de detección seguir los siguientes pasos: 
Gire el selector 

SENS 

a la posición máxima, el selector 

LUX 

a la posición 

 y el selector 

TIME 

a la posición mínima. 

Muévase en los límites del campo de detección para comprobar la cobertura. Los límites 
de este campo pueden variarse con el selector 

SENS

 

AJUSTE DE LA LUMINOSIDAD:

 El detector de movimiento CIRCUMAT puede ser 

graduado de tal manera que actúe solamente cuando las condiciones de luz estén por 
debajo del nivel seleccionado. Girando el selector 

LUX

 hacia la posición 

 reaccionará en 

cualquier condición de luminosidad. Girando hacia la posición 

 solamente reaccionará en 

condiciones de baja luminosidad. 

 
AJUSTE DEL RETARDO DE CONEXIÓN 

Girando el selector 

TIME

, el tiempo de encendido de la carga podrá fijarse entre los 

siguientes valores: 

 Posición 

: encendido 1 segundo, apagado 9 s. Tiempo mínimo. 

  Posiciones de 3 s a 30 min.: encendido de 3 s, 15 s, 1 min., 5 min., 10 min., 20 min. y 30 

min. (tiempo máximo). Las temporizaciones de 3 s a 30 minutos se reinician en cada 
captación realizada. 

Colocar de nuevo la tapa frontal, teniendo cuidado de hacer coincidir los índices marcados 
en ambas piezas. 

 
CARACTERÍSTICAS TÉCNICAS 

Alimentación:  

230 V~  50 Hz 

Poder de ruptura: 

μ

 5 A  230 V~ cos 

φ

=1 

Consumo propio: 

1 W (7,5 VA)  

Sensibilidad lumínica: 

5 – 1000  Lux.  

Rango de temporización: 

De 3 segundos a 30 minutos 

Angulo de detección: 

360º 

Altura máxima de detección: 

3 metros 

Temperatura de funcionamiento: 

-20 ºC a +40 ºC 

Tipo de protección: 

IP 20 según EN 60529 

Clase de protección 

II en condiciones de montaje correctas.

  

 

 
 
 

ENG 

 
 

MOTION DETECTOR

 

 
INSTRUCTIONS FOR USE 

 

FIG.1 

1. 

Cover 

2.

 Connection terminals 

3.

 Sensor 

4.

 Selectors 

5.

 Securing holes 

 
DESCRIPTION 

The CIRCUMAT motion detector captures invisible infrared emissions from people and 
other heat sources without emitting any form of radiation. 
When a heat source moves below the CIRCUMAT, its output circuit is activated. When it no 
longer captures the movement, it will deactivate after an adjustable delay time. 
The motion detector reacts only when light conditions are below the selected level. 
 

INSTALLATION 

WARNING: Electric apparatus assembly and installation must only be carried out by an 
authorised installer. 
ALL POWER MUST BE SWITCHED OFF BEFORE INSTALLING THE UNIT. 
The unit is internally protected against interference by a safety circuit. However, certain, 
especially strong electromagnetic fields could alter its operation, for which reason it must 
not be installed near inductive fields (motors, transformers, transformer substations and 
industrial machinery, etc) neither wireless high frequency signals (WI-FI, mobile phone, 
signal inhibitors, etc.). 
 

INSTALLATION AND CONNECTION 

On the ceiling, avoiding highly reflective surfaces in its detection area (liquids and marble 
etc), elements subject to brusque temperature changes (heaters, air conditioning and air 
currents etc) or light sources. 
The installation of any motion detector must take into account that detection is produced by 
the crossing of its detection beams and therefore, if the heat source to be detected is 
moving parallel to the beams, the detection is produced at less distance because it will not 
cross the beams until it is very close to the unit. 
In the drawing of 

FIG.2

, arrows indicate the direction of movement of the person or object 

to be detected. 
The detection area depends directly on the installation height according to 

FIG.2

 
Remove the front cover as shown in 

FIG.3

. Fix the unit to the ceiling using the two supplied 

screws through the securing holes. Connect the wires to the terminal screws in accordance 
with the wiring diagram of 

FIG.4

.  

 
PUTTING INTO OPERATION 

After connecting the unit, the system should be checked during sixty seconds 
approximately, after which time the unit is ready to operate and the selected adjustments 
can be made. 
With the cover removed, three selectors are available for the various adjustments that can 
be made to the CIRCUMAT. 

FIG.5

 

 

DETECTION INDICATORS 

A red LED indicates the CIRCUMAT status as follows: 

 

Flashing: the motion detector is in “STAND BY” and ready to detect movement. 

 

Off: lighting conditions are above the programmed value. 

 

Fixed On: the unit is detecting movement. 

 
ADJUSTING THE DETECTION FIELD: 

The ambient temperature in the location where the CIRCUMAT is installed, can have quite 
an influence on the detection sensitivity and hence, on the detection distance. With 
increasing temperatures, the detection becomes poorer, because the unit operates by 
detecting the movement of a heat source (in the majority of cases, the 36 ºC temperature of 
the human body), the closer the ambient temperature is to 36 ºC, the poorer the detection. 
 
The detection field is adjusted as follows: 
Set the 

SENS 

selector to maximum, the 

LUX 

selector to the 

 position and the 

TIME 

selector to minimum. 
Move within the detection field limits to verify coverage. The limits of this field can be varied 
using the 

SENS

 selector. 

 

ADJUSTING LUMINOSITY.

 The CIRCUMAT motion detector can be adjusted so that it 

operates only when lighting conditions are below the selected level. Setting the 

LUX

 

selector to the 

 position will cause it to operate under any lighting conditions. Turn it to the 

 position and it will only operate under low lighting conditions. 

 
ADJUSTING THE CONNECTION DELAY  

Turning the 

TIME

 selector enables the load switch-on to be fixed between the following 

values: 

 Position

: On for 1 second, Off for 9 seconds. Minimum time. 

  Positions 3 seconds to 30 minutes: On for 3 seconds, 15 seconds, 1, 5, 10, 20 and 30 

minutes (maximum time). The 3 second to 30 minute times is reinitiated with each new 
capture. 

Replace the front cover, taking care to make the index marks coincide on both parts. 

 
TECHNICAL SPECIFICATIONS 

Power supply:  

230 Vac, 50 Hz 

Breaking power: 

μ

 5 A, 230 Vac cos 

φ

=1 

Power consumption: 

1 W (7.5 VA)  

Light sensitivity: 

5 – 1,000 Lux.  

Timing range: 

3 seconds to 30 minutes 

Detection angle: 

360º 

Maximum detection height: 

3 metres 

Operating temperature: 

-20 ºC to +40 ºC 

Protection type: 

IP 20 according to EN 60529 

Protection class 

II under correct installation conditions. 

 
 
 
 
 
 

 

FRA 

 
 

DETECTEURS DE MOUVEMENT

 

 
MODE D’EMPLOI 

 

FIG.1 

1.- 

Couvercle 

2.-

 Bornes de connexion 

3.-

 Capteur 

4.-

 Sélecteurs 

5.-

 Perforations de fixation 

 
DESCRIPTION 

Le détecteur de mouvement CIRCUMAT capte les émissions invisibles infrarouges 
provenant des personnes et d’autres sources de chaleur sans émettre aucun type de 
radiation. 
Lorsqu’une source de chaleur bouge sous le CIRCUMAT, son circuit de sortie s’active. Une 
fois qu’il ne capte plus de mouvement, il se désactive après un délai de retard réglable. 
Le détecteur de mouvement ne réagit que lorsque les conditions de lumière sont en 
dessous du niveau sélectionné. 

 

INSTALLATION 

ATTENTION : l’installation et le montage des appareils électriques doivent être réalisés par 
un installateur autorisé. 
AVANT DE PROCÉDER À L’INSTALLATION, DÉCONNECTEZ L’ALIMENTATION. 
L’appareil est internement protégé contre les interférences par un circuit de sécurité. 
Toutefois, certains champs électromagnétiques particulièrement forts peuvent arriver à 
altérer son fonctionnement. Par conséquent, il ne doit pas être installé à proximité de 
champs inductifs (moteurs, transformateurs, centres de transformation, machinerie 
industrielle, etc.) ou des signaux sans fil à haute fréquence (WIFI, télephonie, inhibteur de 
signal. etc.). 
 

MONTAGE ET CONNEXION 

Sur toit, en évitant que dans sa zone de détection se trouvent des surfaces hautement 
réfléchissantes (liquides, marbre, etc.), des éléments sujets à de brusques changements 
de température (chauffage, air climatisé, possibles courants d’air, etc.) ou des sources 
lumineuses. La zone de détection dépend directement de la hauteur de montage, selon la 

FIG.2

Lors de l’installation de tout détecteur de mouvement, il faut tenir compte du fait que la 
détection se produit lorsque l’on croise ses faisceaux de détection et que, par conséquent, 
si la source de chaleur à détecter avance parallèlement aux faisceaux, la détection se 
produit à une plus faible distance, puisque qu’elle ne traverse pas les faisceaux que 
lorsqu’elle arrive très près de l’appareil (

FIG.2

). 

Retirez le couvercle tel que montre le dessin de la 

FIG.3

. Fixez la base au toit à travers les 

trous en forme de fente à l’aide de deux vis incluses. Réaliser la connexion des 
conducteurs au moyen des bornes à vis. Connectez conformément au schéma de la 

FIG.4

 

 
MISE EN MARCHE 

Après la connexion, l’appareil réalise une vérification du système pendant environ 60 
secondes, une fois ce délai écoulé il est préparé pour fonctionner et réaliser les ajustages 
sélectionnés. 
En retirant le couvercle, les trois sélecteurs restent au découvert pour les différents 
ajustages qui peuvent se réaliser dans le fonctionnement du CIRCUMAT. 

FIG.5

 

 

INDICATEURS DE DÉTECTION 

Un led rouge indique l’état du CIRCUMAT de la façon suivante: 

 Clignotement: Le détecteur de mouvement est en “STAND BY” en attendant un 

mouvement. 

  Éteint : Les conditions de luminosité sont au-dessus de celle programmée. 

  Allumé en permanence: L’équipement détecte du mouvement. 

 
AJUSTAGE DU CHAMP DE DÉTECTION: 

La température ambiante de l’enceinte où est installée le CIRCUMAT a une influence 
relativement importante sur la sensibilité de la détection et, par conséquent, sur la distance 
de détection. Etant donné que l'appareil fonctionne par détection du mouvement d'une 
source de chaleur (dans la plupart des cas 36 ºC est la température du corps humain), plus 
la température est élevée, plus la sensibilité est faible. Plus la température ambiante se 
rapproche de 36 ºC plus la détection est faible. 
Pour ajuster le champ de détection, suivre les pas suivant: 
Tourner le sélecteur 

SENS

 à la position maximale, le sélecteur

 LUX

 à la position 

 et le 

sélecteur 

TIME 

à la position minimale. 

Bouger dans les limites du champ de détection pour vérifier la couverture. Les limites de ce 
champ doivent se varier avec le sélecteur 

SENS

 

RÉGLAGE DE LA LUMINOSITÉ

:

 

Le détecteur de mouvement CIRCUMAT peut être 

gradué de façon à agir

 

seulement lorsque les conditions de lumière sont en dessous du 

niveau sélectionné. En tournant le sélecteur 

LUX

 jusqu’à la position 

, il réagira dans 

n’importe quelle condition de luminosité. En tournant jusqu’à la position 

, il ne réagira que 

dans des conditions de luminosité faible. 
 

RÉGLAGE DU DÉLAI DE CONNEXION

 

En tournant le sélecteur

 

TIME

, le temps d’allumage de la charge pourra se fixer entre les 

valeurs suivantes : 

 Position 

: allumé 1 seconde, éteint 9 s. Temps minimum. 

  Positions de 3 s à 30 min. allumé de 3 s, 15 s, 1 min., 5 min., 10 min., 20 min. et 30 min. 

(temps maximum). Les temporisations de 3 s à 30 minutes se rétablissent à chaque 
captage réalisé. 

Placer à nouveau le couvercle frontal, en prenant soin de faire coïncider les indices 
marqués dans les deux pièces. 

 
CARACTÉRISTIQUES TECHNIQUES 

Alimentation:  

230 V~  50 Hz 

Pouvoir de Coupure: 

μ

 5 A  230 V~ cos 

φ

=1 

Consommation propre : 

1 W (7,5 VA)  

Sensibilité luminique : 

5 – 1000  Lux.  

Rang de Temporisation: 

De 3 secondes à 30 minutes 

Angle de détection: 

360º 

Hauteur maximales de détection: 

3 mètres 

Température de fonctionnement: 

-20 ºC à +40 ºC 

Type de protection: 

IP 20 selon EN 60529 

Classe de protection 

II en conditions de montage correct. 

 
 

 

ORBIS TECNOLOGÍA ELÉCTRICA, S.A. 

Lérida, 61          E–28020  MADRID 

Tel.:+ 34 91 5672277;  Fax:+34 91 5714006 

E-mail: info@ orbis.es 

http://www.orbis.es

 

Отзывы: