2004 EDITION
CW-3/9
www.orbinox.com
MODEL
CW
It should be noted that the direction of flow and differential pressure, do not always coincide.
Special care should be taken to maintain the correct distance between the flanges and to
ensure that they are parallel to the valve body. Incorrect alignment of the valve can cause
deformations, which can lead to difficulties in operation.
The following table gives the maximum torque values for the valve fixing bolts. Also shown is
the maximum depth (T) allowed for the tapped blind boltholes drilled into the valve body.
DN
80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000
T (mm) 13 13
13
13
18
18
21
25
25
25
25
35
Kg.m
6
6
7
7
7
11
11
15
15
19
19
23
23
28
28
34
The valve can be mounted in any position with regard to the pipe. However, it is advisable to
place it vertically in horizontal pipeline (A) if the installation allows it. (Please consult the
technical department at Orbinox).