OGi Modem - Hardware Guide
T401, Version .15 36 © ORBCOMM Proprietary
CAUTION
Adhesive or silicone cannot block the air vent features shown
in Figure 24.
Figure 24 Air Vent Feature
5.
Secure the antenna in place with self-tapping screws or machine screws and nuts
depending on access to the mounting surface. The remote antenna might also be
mounted using adhesive or a high strength outdoor grade silicone when mounting
holes are not an option in the mounting surface.
Note:
The recommended torque specification is approximately finger tight plus a
45 degree rotation using an 8 mm wrench.
CAUTION
Cable management and connector strain relief
MUST
be
incorporated in the installation. Secure the cable no more
than 15 cm from the enclosure and at regular intervals along
its length as part of the installation to prevent cable wear and
eliminate strain on the terminal connector. Damage to the
connector interface or cable might otherwise result leading to
hardware failure.
5.2.2 Adhesive Mount
The remote antenna might also be mounted using adhesive or a high strength outdoor
grade silicone when mounting holes are not an option in the mounting surface.
Refer to the adhesive manufacturer's recommendations for application temperature,
application conditions, compatible bonding materials, and minimum curing times when
working with an adhesive. Failure to follow the manufacturer's guidelines could result in
the remote antenna separating from the mounting surface.
CAUTION
Adhesive or silicone cannot block the air vent features shown
in Figure 25.
Do Not Block These Features