OPTIMOD-PC
OPERATION
3-69
Creating Custom “Factory” Presets
You can create custom “factory” presets that support
L
ESS
-M
ORE
functionality.
These presets will behave like Orban’s factory presets.
Your 1101’s software has the ability to interpolate all 19 available
L
ESS
-
More incre-
ments (1.0 through 10.0) from two or more
L
ESS
-M
ORE
“anchor” preset files. In addi-
tion, there must be a “factory preset” file. The instructions below show you how to
create these files from user preset files that you have saved.
In the examples below, the specified file locations are based on OPTIMOD-PC’s de-
fault locations. Using Windows Explorer, check the factory preset file locations on
your computer to find out where these files are actually located. You must place
your new “factory preset” files in analogous locations.
To create a custom “factory” preset:
1.
Choose a name for the preset.
You cannot use the name of an existing factory preset without damaging it. We
will use “My Preset” as the preset name in the examples below.
2.
Create a folder for your presets.
Create a folder named “My Preset” within the directory
\Program Files\Orban\OPTIMOD-PC2\presets
You should see all of the subdirectories for Orban’s factory presets in this
director
3.
Choose the default
L
ESS
-M
ORE
value for your preset.
4.
Using the OPTIMOD-PC Control Application, create user presets for each
L
ESS
-M
ORE
anchor point.
starting on page 1-17.
Because
L
ESS
-M
ORE
works only on the dynamics processing, you must choose a
set of equalizer settings for your new preset that is the same for all anchor pre-
sets.
on page 3-37 shows the controls that must be
set identically in all anchor presets.
You must create at least two anchor presets, one for
L
ESS
-M
ORE
= 1.0 and one
for
L
ESS
-M
ORE
= 10.0. Additionally, if the default
L
ESS
-M
ORE
value you chose in
step 3 is neither 1.0 nor 10.0, you must create a third anchor preset for the de-
fault
L
ESS
-M
ORE
value.
You may add as many additional anchor presets as you wish to fine-tune the be-
havior of
L
ESS
-M
ORE
. Some Orban factory presets use as many as six anchor pre-
sets.
From the OPTIMOD-PC Control Application, save each preset as a user preset in
plain text (unencrypted) form, naming it
My Preset LMxxx
, where
xxx
stands for
Содержание Optimod-PC 1101
Страница 4: ......
Страница 14: ......
Страница 121: ...OPTIMOD PC OPERATION 3 1 Section 3 Operation Figure 3 1 The OPTIMOD PC Control Application...
Страница 192: ...3 72 OPERATION ORBAN MODEL 1101...
Страница 204: ......
Страница 210: ......
Страница 212: ...5 2 UNINSTALLATION ORBAN MODEL 1101...
Страница 236: ......