Orban Optimod-AM 9200 Скачать руководство пользователя страница 10

A-10 

 OPTIMOD-AM 9200 

VERSION 3.0 SOFTWARE ADDENDUM

 

Parameter Labels 

Units

Your Settings 

Range (CCW to CW) 

AO-2 OUTPUT CALIBRATE 

 

LF BKPT 

Hz

 

3 … 50 

LF GAIN 

dB

 

0.0 … 10.0 

HF DELAY 

 

off, 1 … 60 

HF SHELF 

Hz

 

off, 50000 … 500 

 

 

 

AO-2 NIGHT OUTPUT CALIBRATE 

HF DELAY 

 

off, 1 … 60 

HF SHELF 

Hz

 

off, 50000 … 500 

 

 

 

DIGITAL OUTPUT CALIBRATE: screen 1 

DO 100% 

dBFS

 

-20.0 … 0.0, conflict 

DO RATE 

kHz

 

32, 44.1, 48 

DO SYNC 

 

internal, external 

 

 

 

DIGITAL OUTPUT CALIBRATE: screen 2 

HF DELAY 

 

off, 1 … 60 

HF SHELF 

Hz

 

off, 50000 … 500 

 

 

 

DIGITAL NIGHT OUTPUT CALIBRATE 

HF DELAY 

 

off, 1 … 60 

HF SHELF 

Hz

 

off, 50000 … 500 

 

 

 

PC REMOTE SETUP 

 

 

SET PASSCODE 

 

 

SET MODEM INIT 

 

 

 

 

 

REMOTE INTERFACE (four screens) 

REMOTE INTERFACE 1…8

 

User Presets 01- … 08- 

gen purpose medium 

gen purpose heavy 

news 

news + nr  

sports 

fine arts 

music medium 

music heavy 

day mode 

night mode 

test: bypass 

test: sinewave 

exit test 

analog in 

digital in 

no function 

 

Содержание Optimod-AM 9200

Страница 1: ...Operating Manual Addendum OPTIMOD AM 9200 Digital Audio Processor Version 2 0 and Version 3 0 Software...

Страница 2: ...d Out 7 Disabling Passcode Protection 7 VERSION 3 SOFTWARE 7 New Presets 7 New User Control 8 Ethernet Support 8 APPENDIX 1 9200 SYSTEM SETTINGS SHEET 9 APPENDIX 2 9200 USER PRESET SETTINGS SHEET 11 O...

Страница 3: ...ight positive peak control for improved nighttime coverage Front panel security lockout 9200 HF Presets The HF presets have been designed to meet the exacting needs of international shortwave broadcas...

Страница 4: ...te levels or frequencies Orban s analog Optimod HF 9105 has achieved widespread acceptance amongst the world s most prestigious national HF broadcasting organizations The HF 9200 presets have been tun...

Страница 5: ...t plan to use 9200 PC Remote software setting a passcode is optional A timer that locks out the front panel after a certain period of control inactivity achieves local protection of the 9200 The LOCKO...

Страница 6: ...the lockout delay time in minutes or hours from 5 min utes to 8 hours or off This is time delay between the last access to a local front panel control and when the front panel automatically locks itse...

Страница 7: ...ape buttons simultaneously While holding both buttons down power up the 9200 Keeping holding the buttons down after power has been applied after about three seconds the following screen will appear RE...

Страница 8: ...l and unpleas ant on wideband radios of which there are very few in the market If you feel that the preset has too much distortion feel free to turn it down it with LESS MORE to taste The factory LESS...

Страница 9: ...NITE MODE POS PEAK ANALOG INPUT CALIBRATE INPUT1 analog digital AI REF VU dBu High Range 9 0 13 0 Low Range 31 0 9 0 AI REF PPM dBu High Range 1 0 21 0 Low Range 23 0 1 0 AI CLIP dBu High Range 5 0 2...

Страница 10: ...dBFS 20 0 0 0 conflict DO RATE kHz 32 44 1 48 DO SYNC internal external DIGITAL OUTPUT CALIBRATE screen 2 HF DELAY off 1 60 HF SHELF Hz off 50000 500 DIGITAL NIGHT OUTPUT CALIBRATE HF DELAY off 1 60 H...

Страница 11: ...0 LF WIDTH oct 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 7 1 9 2 0 2 2 2 4 2 6 2 8 3 0 3 3 3 5 3 7 4 0 LF GAIN dB 10 0 10 0 EXPERT EQ MF EQ MID BASS dB 0 12 MF FREQ Hz 250 4 000 MF WIDTH oct 0 8 0 9 1 0 1 1 1...

Страница 12: ...z 150 200 EXPERT CONTROL 5B INPUT DRIVE screen 1 B1 DRIVE dB 3 0 3 0 B2 DRIVE dB 3 0 3 0 B3 DRIVE dB 3 0 3 0 B4 DRIVE dB 3 0 3 0 EXPERT CONTROL 5B INPUT DRIVE screen 2 B2 DRIVE dB 3 0 3 0 B3 DRIVE dB...

Отзывы: