13
Servicing/changing the solenoid valve membrane
– Close the water inlet to the fl usher.
Figure 8:
– Undo the fl usher cover locking screw (3).
– Detach the fl usher cover by lifting it simultaneously up and outwards.
Figure 9:
– Unscrew the solenoid valve membrane socket (8).
– Clean the membrane or if necessary change for a new one.
Remove any dirt inside the membrane socket.
– Reassemble in reverse order.
– Open the water inlet to the fl usher.
Cleaning/changing the litter fi lter
6567:
– Close the water inlet to the fl usher.
– Undo the fl usher locking screw (1) (fi gure 8).
– Detach the fl usher.
– Remove the litter fi lter (2) from the fl usher e.g. with pliers.
– Clean the litter fi lter under running water or put the new litter fi lter in place.
– Reassemble in reverse order.
– Open the water inlet to the fl usher.
6568:
– Close the water inlet to the fl usher.
– Detach the fl usher.
– Remove the litter fi lter (4) from the inlet union nut e.g. with pliers.
– Clean the litter fi lter under running water or put the new litter fi lter in place.
– Reassemble in reverse order.
– Open the water inlet to the fl usher.
Troubleshooting
SYMPTOM
CAUSE/SOLUTION
Water fl ow doesn’t stop
– Solenoid valve is damaged or dirty
Flow-rate has diminished over time
– Litter fi lter is blocked
No water comes from the fl usher
– Check the water inlet to the fl usher
– Solenoid valve is damaged
– Sensor is broken or obstructed
– Battery voltage is too low
Repeating audio signal (once every 5 minutes)
– Sensor is broken or obstructed
Audio signal when user is within recognition range – Battery voltage is too low
If necessary, please seek the best possible advice at an expert HVAC store.