Caution -
Attaching a SAS cable in the wrong orientation at the controller HBA or the disk shelf I/O Module
damages the port connector, and the system will not function properly.
The following procedure connects an AOC cable to the controller and to an Oracle Storage Drive Enclosure DE3-
24P disk shelf. For additional information, see
Oracle ZFS Storage Appliance Cabling Guide
available from
.
1. Facing the controller HBA, position the cable's release tab to the right (left panel) for the controller end, and to
the top for the disk shelf end (#1 in right panel).
2. Insert the cable connectors into the appropriate ports, aligning the cable connector latches (#2 in right panel)
with the port latch receiver holes (#3 in right panel). Ensure the latches engage with the receiver holes.
Power On and Configure the System
Required information: Network host name and port of your serial connection, or network management port DHCP-
assigned address. Connect disk shelf power cables, power on disk shelves, connect controller power cables, power
on controllers, and configure the system as described in the
Oracle ZFS Storage Appliance Installation Guide
available from
https://docs.oracle.com/en/storage
.
Perform Initial Configuration
For detailed information, see the
Oracle ZFS Storage Appliance Installation Guide
available from
, including properly configuring management interfaces and updating controller software.
5