Preinstallation Tasks
Preinstallation
1-5
Task 3: Start the Processes Necessary for Installation
1.
Start the database:
$ svrmgrl
SVRMGR> connect internal
Connected to an idle instance.
SVRMGR> startup
SVRMGR> exit
2.
Start the network listener:
$ lsnrctl start
Task 4: Configure Net8 (Database Node Installation) TNSLISTENER80
To install an Unified Messaging database node, a connect string must exist that
provides a connection to the Unified Messaging database using the sid.
1.
Verify that the entry exists in the
TNSNAMES.ORA
file for the Unified Messaging
sid. If it does not exist, add the following:
<connect string> =
(DESCRIPTION=
(ADDRESS_LIST =
(ADDRESS = (PROTOCOL = tcp)
(HOST = <um host name>)
(PORT = <listener port>)
)
)
)
Example:
ORCL.world =
(DESCRIPTION=
(ADDRESS_LIST =
(ADDRESS = (community = tcp.world) (PROTOCOL =tcp)
(HOST = um.acme.com)
(PORT = 1521)
)
)
(CONNECT_DATA = (SERVICE_NAME = ORCL)
)
)