Disconnect Cables From the Server
■
“Power Down Server Gracefully Using the Power Button” on page 77
■
“Disconnect Cables From the Server” on page 80
■
“Power On the Server” on page 214
Disconnect Cables From the Server
Caution -
The system supplies standby power to the circuit boards even when the system is
powered off.
1.
Label all cables connected to the server.
2.
Disconnect the power cables from the rear of the server.
3.
Disconnect all data cables from the rear of the server.
4.
If your rackmount kit includes a cable management device, remove the cables
from it.
5.
Remove the server from the rack.
Related Information
■
“Rear Panel Cable Connections” on page 17
■
“Powering Down the Server” on page 76
■
“Remove the Server From the Rack” on page 80
■
“Reconnect Power and Data Cables” on page 213
Remove the Server From the Rack
Remove the server from the rack.
Remove the server from the rack prior to performing component replacement procedures. Make
sure to place the server on a stable work surface.
Caution -
The server weighs approximately 41 lbs (18.6 kg). Two people are required to
dismount and carry the chassis.
80
Sun Netra X4270 Server • September 2015
Содержание Sun Netra X4270
Страница 1: ...Sun Netra X4270 Server Service Manual Part No E23171 03 September 2015 ...
Страница 2: ......
Страница 10: ...10 Sun Netra X4270 Server September 2015 ...
Страница 12: ...12 Sun Netra X4270 Server September 2015 ...
Страница 36: ...36 Sun Netra X4270 Server September 2015 ...
Страница 72: ...72 Sun Netra X4270 Server September 2015 ...
Страница 100: ...100 Sun Netra X4270 Server September 2015 ...
Страница 224: ...224 Sun Netra X4270 Server September 2015 ...
Страница 230: ...WDT W WDT watchdog timers 230 Sun Netra X4270 Server September 2015 ...
Страница 237: ...Index V video port location 17 pinout 219 visual notification 29 W watchdog timer setting 50 weight of server 80 237 ...
Страница 238: ...238 Sun Netra X4270 Server September 2015 ...