Verify Card Status
7. Extract SMART Logs
Select Operation [1-7 or 0:Quit]: 2
Enter Flash Package File: /home/user/ELP-4x200-3d-n_09.05.24.00.bin
Command Line Interface Usage:
Enter the following line of text in the CLI to run the
-
updatepkg
command:
ddcli -c 1 -updatepkg SLP-300_01.02.00.00.bin
ddcli -c
<card number>
-updatepkg
<
flash package file
>
Error Handling
: The following statements are true with regard to error handling:
■
If a controller firmware update fails, the
-updatepkg
command terminates.
■
If a firmware download fails on any of the card components, the process terminates.
Related Information
■
“Update the Card Firmware” on page 34
■
“Exception Handling” on page 56
■
Utility Command Summary” on page 38
Health Reporting Command
The
-health
command shows the overall health status of a selected card and its components. If
any alert exists, this command shows the component that is causing the alert, along with further
information. Use the
-health
command to verify firmware versions before and after firmware
updates.
Text Menu Interface Usage
: The following top-level menu lists the cards in the system and
prompts you to select a card on which to perform an operation. Four Sun Flash Accelerator F80
PCIe Cards are shown in the following example:
# ddcli
ID WarpDrive Package Version PCI Address
-- --------- --------------- -----------
1 ELP-4x200-4d-n 09.05.24.00 00:02:00:00
2 ELP-4x200-4d-n 09.05.24.00 00:03:00:00
3 ELP-4x200-4d-n 09.05.24.00 00:04:00:00
4 ELP-4x200-4d-n 09.05.24.00 00:05:00:00
Select the WarpDrive [1-4 or 0:Quit]: 1
1. List WarpDrive Information
2. Update Flash Package
3. Display WarpDrive Health
44
Sun Flash Accelerator F80 PCIe Card User's Guide • December 2013