Network Management Port 1 Does Not Work (CR 6935471 and 6854694)
7.
Use the
show
command to view and confirm the firmware version that is installed
on the NEM.
8.
Repeat steps 1 through 7 for NEM1.
9.
Press ESC in the BIOS Setup Utility to restart the boot process.
Network Management Port 1 Does Not Work (CR 6935471
and 6854694)
The CMM has two network management ports. The connectors are labelled NET MGT 0 and
NET MGT 1.
NET MGT 1 does not work. Use NET MGT 0 to connect the CMM to the Ethernet.
If you need to connect to more than one network, use an external Ethernet switch.
Note -
Oracle ILOM allows you to select which management port to use. Even if you select port
1, it does not switch ports.
start /SYS
and
stop /SYS
Commands Cause Power Button
Pressed Event In Log (CR 6906176)
When you enter the
start /SYS
and
stop /SYS
commands, it causes a Power Button Pressed
event to be logged. This log entry is incorrect.
You can ignore these log entries.
Event Log Messages Might Be Out of Sequence and
Duplicated (CR 6915976)
Messages in the event log might be out of sequence and duplicated. For example:
14 Fri Apr 16 05:42:50 2010 IPMI Log critical
ID = a : 04/16/2010 : 05:42:50 : System Firmware Progress : BIOS : Man
agement controller initialization
Oracle ILOM Enhancements and Issues
81
Содержание Sun Fire X4800
Страница 1: ...Sun Fire X4800 Server Product Notes Part No E69641 07 July 2017 ...
Страница 2: ......
Страница 12: ...12 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 26: ...26 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 60: ...60 Sun Fire X4800 Server Product Notes July 2017 ...
Страница 88: ...88 Sun Fire X4800 Server Product Notes July 2017 ...