Verify a DIMM
■
“Understanding DIMM Configurations” on page 69
■
“Identifying DIMMs” on page 71
■
■
■
“DIMM Configuration Errors” on page 72
Verify a DIMM
1.
Use the
show faulty
command to determine how to clear the fault.
■
If
show faulty
indicates a POST-detected fault, go to
Broken Link (Target ID: GOZPJ)
.
■
If
show faulty
output displays a UUID, which indicates a host-detected fault, skip
Broken
Link (Target ID: GOZPJ)
and go directly to
Broken Link (Target ID: GOZQE)
.
2.
Use the
set
command to enable the DIMM that was disabled by POST.
In most cases, replacement of a faulty DIMM is detected when the SPM is power cycled. In
those cases, the fault is automatically cleared from the server. If
show faulty
still displays the
fault, the
set
command clears it.
->
set /SYS/MB/CM0/CMP/MR0/BOB1/CH0/DIMM clear_fault_action=true
Are you sure you want to clear /SYS/MB/CM0/CMP/MR0/BOB1/CH0/DIMM (y/n)?
y
Set 'clear_fault_action' to ‘true’
3.
For a host-detected fault, perform the following steps to verify the new DIMM.
a.
Set the virtual keyswitch to
diag
so that POST runs in Service mode.
->
set /HOST keyswitch_state=Diag
Set 'keyswitch_state' to 'Diag'
b.
Stop the host.
->
stop /System
Are you sure you want to stop /System (y/n)?
y
Stopping /System
c.
Check if the host has been powered off.
Allow approximately one minute before performing this step. Type the
show /HOST
command. When the host is powered off, the console displays
status=Powered Off
.
d.
Start the host.
84
SPARC T8-4 Server Service Manual • January 2022
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...