Servicing Power Supplies
The server has redundant hot-serviceable power supplies. You can remove and replace a power
supply without shutting the server down, provided that the other power supply is online and
working.
For information about power configuration policies, refer to
Servers Administration
and the
Oracle ILOM documentation.
These topics describe how to service power supply modules.
■
“Power Supply LEDs” on page 85
■
“Determine Which Power Supply Is Faulty” on page 87
■
“Remove a Power Supply” on page 87
■
“Install a Power Supply” on page 88
■
“Verify a Power Supply” on page 90
Related Information
■
“Servicing the PS Backplane” on page 165
Power Supply LEDs
Each power supply has LEDs that indicate its state.
Servicing Power Supplies
85
Содержание SPARC T7-2
Страница 1: ...SPARC T7 2 Server Service Manual Part No E54987 10 July 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T7 2 Server Service Manual July 2019 ...
Страница 12: ...12 SPARC T7 2 Server Service Manual July 2019 ...
Страница 28: ...28 SPARC T7 2 Server Service Manual July 2019 ...
Страница 64: ...64 SPARC T7 2 Server Service Manual July 2019 ...
Страница 84: ...84 SPARC T7 2 Server Service Manual July 2019 ...
Страница 112: ...112 SPARC T7 2 Server Service Manual July 2019 ...
Страница 116: ...116 SPARC T7 2 Server Service Manual July 2019 ...
Страница 120: ...120 SPARC T7 2 Server Service Manual July 2019 ...
Страница 134: ...134 SPARC T7 2 Server Service Manual July 2019 ...
Страница 146: ...146 SPARC T7 2 Server Service Manual July 2019 ...
Страница 164: ...164 SPARC T7 2 Server Service Manual July 2019 ...
Страница 170: ...170 SPARC T7 2 Server Service Manual July 2019 ...
Страница 176: ...176 SPARC T7 2 Server Service Manual July 2019 ...
Страница 182: ...182 SPARC T7 2 Server Service Manual July 2019 ...
Страница 188: ...188 SPARC T7 2 Server Service Manual July 2019 ...