DIMM Configuration Fault Messages
76
SPARC T5-8 Server Service Manual • November 2015
6.
Press the DIMM Fault Remind button on the processor module.
This will cause DIMM Fault LED associated with the faulty DIMM to light for a few minutes.
7.
Confirm that the DIMM next to the illuminated DIMM Fault LED is the same DIMM
that was reported to be faulty by the
fmadm
faulty
command.
See
“Determine Which DIMM Is Faulty (FMA)” on page 73
.
8.
Visually check to ensure that all of the other DIMMs are seated properly in their
slots.
Related Information
■
“Determine Which DIMM Is Faulty (FMA)” on page 73
■
“Remove a DIMM or DIMM Filler Panel” on page 76
DIMM Configuration Fault Messages
When the system boots, system firmware checks the memory configuration against the rules
described in
“DIMM Configuration” on page 71
. If it discovers any faults, one or more
rule-specific messages will be displayed in the POST output indicating the type of configuration
fault that has been discovered.
Related Information
■
“DIMM Configuration” on page 71
■
“Determine Which DIMM Is Faulty (FMA)” on page 73
■
“Determine Which DIMM Is Faulty (LEDs)” on page 75
■
“Remove a DIMM or DIMM Filler Panel” on page 76
Remove a DIMM or DIMM Filler Panel
DIMMs are cold-service components that can be replaced after you remove the processor
module from the server.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail.
Before beginning this procedure, ensure that you are familiar with the cautions and safety
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...