Servicing the Rear Chassis Subassembly
181
Servicing the Rear Chassis Subassembly
The rear chassis subassembly is a cold-service component that can be replaced only by qualified
service personnel. You must remove all of the power from the server before you attempt to
remove the rear chassis subassembly. For the location of the rear chassis subassembly, see
“Rear Panel Components (Service)” on page 15
.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail.
These topics describe service procedures for the rear chassis subassembly in the server.
Steps
Description
Links
1.
Determine if the rear chassis subassembly is faulty
using the system software.
“Determine if the Rear Chassis Subassembly Is
2.
If the rear chassis subassembly is faulty, shut the
server down.
“Removing Power From the Server” on page 53
3.
Remove the rear chassis subassembly.
4.
Install the rear chassis subassembly.
5.
Return the server to operation.
“Returning the Server to Operation”
6.
Verify the installation.
Related Information
■
■
“Detecting and Managing Faults”
■
■
“Component Service Task Reference” on page 23
■
“Returning the Server to Operation”
Determine if the Rear Chassis Subassembly Is Faulty
1.
Log in to Oracle ILOM.
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...