Determine Which PCIe Card Is Faulty
Servicing PCIe Cards
155
No.
LED
Icon
Description
3
Power OK LED
(green)
Indicates these conditions:
■
Off
– PCIe card is not running. You can safely remove the card or install a new card.
■
Steady on
– PCIe card is powered on and is running in its normal operating state. No
service actions are required. You cannot remove the PCIe card.
■
Blinking
– PCIe card is powering up or powering down. You cannot insert or remove
the card.
4
Service Required
LED (amber
The Service Required LED indicates these conditions:
■
Off
– PCIe card is operating normally.
■
On
– PCIe card requires service.
Determine Which PCIe Card Is Faulty
The following LEDs are lit when a fault is detected:
■
System Service Required LEDs on the front panel and rear I/O module
■
System Rear PCIe LED on the front panel
■
Service Required LED on the faulty PCIe card
1.
Determine if the System Service Required LEDs are lit on the front panel or the
rear I/O module.
“Interpreting LEDs” on page 29
2.
Determine if the rear PCIe LED is lit on the front panel.
“Front Panel Controls and LEDs” on page 31
.
3.
From the rear of the server, find the PCIe card that has an amber Service
Required LED lit.
4.
Remove the faulty PCIe card.
“Remove a Card Carrier” on page 155
.
Remove a Card Carrier
The server supports single-wide and double-wide card carriers. The removal steps are the same
for both carrier widths. This topic includes illustrations only for the single-wide carrier.
Note -
If you are installing a PCIe card that requires a double-wide carrier, you must remove
two single-wide carriers.
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...