Determine Which Processor Module Is Faulty
Servicing Processor Modules
61
Determine Which Processor Module Is Faulty
The following LEDs are lit when a processor module fault is detected:
■
Front and rear System Fault (Service Required) LEDs
■
Service Required LED on the faulty processor module
1.
Determine if the Service Required LEDs are illuminated on the front panel or the
rear I/O module.
“Interpreting LEDs” on page 28
2.
From the front of the server, check the processor module LEDs to identify which
processor module needs to be replaced.
“Processor Module LEDs” on page 60
. The amber Service Required LED is lit on the
processor module that needs to be replaced.
3.
Remove the faulty processor module.
“Remove a Processor Module or Processor Filler Module” on page 61
Related Information
■
“Processor Module Components” on page 18
■
“Processor Module LEDs” on page 60
■
“Remove a Processor Module or Processor Filler Module” on page 61
■
“Install a Processor Module or Processor Filler Module” on page 64
■
“Verify the Processor Module” on page 67
Remove a Processor Module or Processor Filler Module
Processor modules and processor filler modules are cold-service components that can be
replaced only after you power off the system. For the location of the modules, see
Caution -
The server can overheat if you leave the server running with the empty processor
module slot open for longer than one minute. To ensure proper airflow, leave the faulty
processor module installed if a replacement processor module or processor filler module is
currently unavailable.
Processor modules are cold-service components that can be replaced only by qualified service
personnel.
Содержание SPARC T5-4
Страница 1: ...Part No E29663 11 July 2016 SPARC T5 4 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 4 Server Service Manual July 2016 ...
Страница 12: ...12 SPARC T5 4 Server Service Manual July 2016 ...
Страница 22: ...22 SPARC T5 4 Server Service Manual July 2016 ...
Страница 44: ...44 SPARC T5 4 Server Service Manual July 2016 ...
Страница 56: ...56 SPARC T5 4 Server Service Manual July 2016 ...
Страница 86: ...86 SPARC T5 4 Server Service Manual July 2016 ...
Страница 96: ...96 SPARC T5 4 Server Service Manual July 2016 ...
Страница 106: ...106 SPARC T5 4 Server Service Manual July 2016 ...
Страница 112: ...Install a Storage Backplane 112 SPARC T5 4 Server Service Manual July 2016 3 Lower the storage backplane into place ...
Страница 129: ...Verify the System Battery Servicing the System Battery 129 Install the System Battery on page 126 ...
Страница 130: ...130 SPARC T5 4 Server Service Manual July 2016 ...
Страница 144: ...144 SPARC T5 4 Server Service Manual July 2016 ...
Страница 162: ...Remove a PCIe Card 162 SPARC T5 4 Server Service Manual July 2016 2 Unlatch and open the PCIe card carrier top cover ...
Страница 172: ...172 SPARC T5 4 Server Service Manual July 2016 ...
Страница 182: ...182 SPARC T5 4 Server Service Manual July 2016 ...
Страница 190: ...190 SPARC T5 4 Server Service Manual July 2016 ...
Страница 198: ...198 SPARC T5 4 Server Service Manual July 2016 ...
Страница 204: ...204 SPARC T5 4 Server Service Manual July 2016 ...