Servicing the System Battery
125
Servicing the System Battery
The system battery is a cold-service component that can be replaced by a customer. For the
location of the system battery, see
“Processor Module Components” on page 18
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
■
“Remove the System Battery” on page 125
■
“Install the System Battery” on page 126
■
“Verify the System Battery” on page 128
Remove the System Battery
The system battery is a cold-service component that can be replaced by a customer.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
1.
Take the necessary ESD precautions.
“Prevent ESD Damage” on page 54
2.
Remove the main module from the server.
“Remove the Main Module” on page 99
3.
Locate the system battery in the main module.
Содержание SPARC T5-4
Страница 1: ...Part No E29663 11 July 2016 SPARC T5 4 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 4 Server Service Manual July 2016 ...
Страница 12: ...12 SPARC T5 4 Server Service Manual July 2016 ...
Страница 22: ...22 SPARC T5 4 Server Service Manual July 2016 ...
Страница 44: ...44 SPARC T5 4 Server Service Manual July 2016 ...
Страница 56: ...56 SPARC T5 4 Server Service Manual July 2016 ...
Страница 86: ...86 SPARC T5 4 Server Service Manual July 2016 ...
Страница 96: ...96 SPARC T5 4 Server Service Manual July 2016 ...
Страница 106: ...106 SPARC T5 4 Server Service Manual July 2016 ...
Страница 112: ...Install a Storage Backplane 112 SPARC T5 4 Server Service Manual July 2016 3 Lower the storage backplane into place ...
Страница 129: ...Verify the System Battery Servicing the System Battery 129 Install the System Battery on page 126 ...
Страница 130: ...130 SPARC T5 4 Server Service Manual July 2016 ...
Страница 144: ...144 SPARC T5 4 Server Service Manual July 2016 ...
Страница 162: ...Remove a PCIe Card 162 SPARC T5 4 Server Service Manual July 2016 2 Unlatch and open the PCIe card carrier top cover ...
Страница 172: ...172 SPARC T5 4 Server Service Manual July 2016 ...
Страница 182: ...182 SPARC T5 4 Server Service Manual July 2016 ...
Страница 190: ...190 SPARC T5 4 Server Service Manual July 2016 ...
Страница 198: ...198 SPARC T5 4 Server Service Manual July 2016 ...
Страница 204: ...204 SPARC T5 4 Server Service Manual July 2016 ...