b. Verify that the
scsi-initiator-id
for each host adapter on the second node is set to
7
.
Use the
show-disks
command to find the paths to the host adapters that are connected to
these enclosures. Select each host adapter's device tree node, and display the node's
properties to confirm that the
scsi-initiator-id
for each host adapter is set to
7
.
{0} ok
cd /pci@6,4000/pci@3/scsi@5
{0} ok
.properties
scsi-initiator-id
00000007
...
If you did not power off
Node B
to install a host adapter, skip to
If you powered off
Node B
to install a host adapter, perform a reconfiguration boot to create the
new Oracle Solaris device files and links.
Check the controller module NVSRAM file revision. If necessary, install the most recent revision.
For the NVSRAM file revision number and boot level, see the
Sun StorEdge RAID Manager
Release Notes
. For the procedure about how to upgrade the NVSRAM file, see the
Sun StorEdge
RAID Manager User’s Guide
.
Verify the controller module firmware revision. If necessary, install the most recent firmware
revision.
For the revision number and boot level of the controller module firmware, see the
Sun StorEdge
RAID Manager Release Notes
. For the procedure about how to upgrade the controller firmware,
see
“How to Upgrade Controller Module Firmware” on page 39
One node at a time, boot each node into cluster mode.
#
reboot
On one node, verify that the device IDs have been assigned to the LUNs for all nodes. These
nodes are attached to the storage array or storage system.
#
cldevice show
(StorEdge A3500 Only)
Verify that the controller module is set to
active/active
mode.
For more information about controller modes, see the
Sun StorEdge RAID Manager Installation
and Support Guide
and the
Sun StorEdge RAID Manager User’s Guide
.
To create a LUN from disk drives that are unassigned, see
“How to Create a LUN” on page 22
To upgrade controller module firmware, see
“How to Upgrade Controller Module Firmware”
18
19
20
21
22
23
24
See Also
Installing Storage Arrays
Chapter 1 • Installing and Maintaining a SCSI RAID Storage Device
21