Understanding Diagnostics
Step
Situation or Task
YES?
Next Step
NO?
Next Step
20.
Does the SP fault LED persist?
Step 40
Step 1
21.
Check the chassis status LEDs. See
Legacy Targets for LED States” on page 57
22.
Do the chassis status LEDs indicate a fault?
Step 1
Step 23
23.
Check the drive status LEDs. See
“Oracle ILOM Legacy Targets for LED States” on page 57
24.
Do the drive LEDs indicate a fault?
Step 1
Step 25
25.
Check the network status LEDs. See
.
26.
Do the network status LEDs indicate a fault?
Step 27
Step 1
27.
Inspect and replace cables as necessary. Then go to Step 1.
28.
Check the logs for information. See
“Display Oracle ILOM Log Entries” on page 35
.
29.
Do the log entries identify the problem?
Step 30
Step 34
30.
Is the problem identified as a hardware problem?
Step 32
Step 31
31.
The problem is software related. See
Server Administration
.
32.
Is sufficient information provided to justify a service operation?
Step 33
Step 34
33.
Perform the service operation on the identified component. See
“Identifying Components” on page 13
.
34.
Is the server fully powered up?
Step 36
Step 35
35.
Fully power up the server. See
“Power On the Server (Oracle ILOM)” on page 261
to Step 36.
36.
Perform general diagnostics. See
“Determining Component Health” on page 43
.
37.
Do the general diagnostics identify any specific component as faulty?
Step 38
Step 31
38.
Perform tests on the specific component. See
“Displaying Faulty Components” on page 46
.
39.
Does the component pass functional tests?
Step 31
Step 33
40.
Replace the motherboard. See
“Servicing the Motherboard” on page 227
. Then go to Step 1.
Related Information
■
“Understanding Diagnostic Tools Available During Server States” on page 23
■
“Access the SP (Oracle ILOM)” on page 28
■
“Network Management Troubleshooting Guidelines” on page 30
Understanding Diagnostic Tools Available During
Server States
These tables describe the diagnostic tools that are available to you, according to the state of the
server.
Detecting and Managing Faults
23
Содержание netra X5-2
Страница 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Страница 2: ......
Страница 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Страница 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Страница 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Страница 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Страница 123: ...Remove a Power Supply 4 Press the release tab to the left and pull on the handle Servicing Power Supplies 123 ...
Страница 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Страница 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Страница 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Страница 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Страница 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Страница 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Страница 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Страница 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Страница 274: ...274 Netra Server X5 2 Service Manual October 2016 ...