Remove the Backplane Data Cable
3.
Route the SAS drive signal cable cable to the drive backplane.
4.
Review this information, and complete these prerequisites in this order.
■
“Install the Fan Tray” on page 255
■
“Install a Fan Module” on page 133
Install all fan modules.
5.
Connect the SAS drive signal cable to the drive backplane connector.
“System Cable Configuration” on page 156
.
6.
Consider your next step.
■
If you installed the cable as part of a replacement operation, go to
.
■
If you installed the cable as part of another component's removal or installation procedure,
return to that procedure.
See
“Component Service Task Reference” on page 65
7.
Finish the installation procedure.
“Returning the Server to Operation” on page 247
Related Information
■
“Remove the SAS Drive Signal Cable” on page 157
■
“Component Locations (Storage, Power, and Fan Modules)” on page 14
■
“Preparing for Service” on page 61
■
“Returning the Server to Operation” on page 247
Remove the Backplane Data Cable
Removing a cable is a cold-service operation. You must power off the server before you remove
the cable.
1.
Determine location of the backplane data cable.
“System Cable Configuration” on page 156
.
2.
Consider your next step.
■
If you have not prepared for service, do so now.
See
“Preparing for Service” on page 61
■
If you are removing a cable as part of another component's removal or installation
Servicing the System Cables
159
Содержание netra X5-2
Страница 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Страница 2: ......
Страница 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Страница 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Страница 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Страница 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Страница 123: ...Remove a Power Supply 4 Press the release tab to the left and pull on the handle Servicing Power Supplies 123 ...
Страница 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Страница 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Страница 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Страница 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Страница 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Страница 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Страница 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Страница 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Страница 274: ...274 Netra Server X5 2 Service Manual October 2016 ...