Remove the LED Board and Cable
1.
On the server, press and hold the Locator button for more than 5 seconds.
See
“Front Panel Components (Service)” on page 17
.
If any of the LEDs do not light, the LED board is faulty.
2.
If the LED board is faulty, replace it.
See
“Remove the LED Board and Cable” on page 218
.
3.
If you are unable to determine if the LED board is faulty, seek further information.
See
“Detecting and Managing Faults” on page 25
Related Information
■
“Remove the LED Board and Cable” on page 218
■
“Verify the LED Board” on page 224
■
“Detecting and Managing Faults” on page 25
■
“Preparing for Service” on page 43
Remove the LED Board and Cable
Removing the LED board is a cold-service operation. You must power off the server before you
remove the LED board.
1.
Prepare for service.
See
“Preparing for Service” on page 43
2.
Review this information and complete these prerequisites in this order.
See:
■
“Removing the Server From the Rack” on page 56
■
“Remove the Filter” on page 79
■
“Rotate the Drive Cage to the Service Position” on page 71
■
“Remove the PSU Duct” on page 74
■
“Remove the Air Duct” on page 75
218
Netra SPARC S7-2 Server Service Manual • February 2017
Содержание Netra SPARC S7-2
Страница 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Страница 2: ......
Страница 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...