Update the Firmware
Related Information
■
“Update the Firmware” on page 84
Update the Firmware
The Live Firmware update feature of the SPARC M7, T7, and S7 series servers supports
updating Sun System firmware while the SPARC host is powered on. The Oracle ILOM
firmware update goes into immediate effect. However, the host components update is delayed
until the affected host is power cycled. Because Oracle ILOM can be updated while the host is
powered on, this feature reduces the total system down time.
Note -
For SPARC T7 servers the Live Firmware Update feature requires a minimum Sun
System Firmware version of 9.5.2.g.
1.
Check the current system firmware version. From the Oracle ILOM command
prompt, type:
-> show /HOST
2.
Download the latest available system firmware version from My Oracle Support
at:
Then place the
SysFW
image in a shared location the host can access, for example, a local or
network share or on a TFTP, FTP, HTTP or HTTPS server.
3.
Notify SP users of the scheduled firmware update and ask them to close all
client sessions until after the firmware update is complete. Do not perform any
other Oracle ILOM tasks during the firmware update.
4.
Update the firmware through the Oracle ILOM CLI.
For information about performing firmware updates using the web interface, see
the Server SP or CMM Firmware Image
Oracle ILOM Administrator's Guide for
Configuration and Maintenance Firmware Release 3.2.x
.
a.
Log in to Oracle ILOM using an account with Admin privileges.
See
“Log In to Oracle ILOM” on page 19
b.
Load the firmware image from the shared location. Type:
load -source protocol://
username:password@server_ip
/
path_to_image
/
image.pkg
84
SPARC and Netra SPARC S7-2 Series Servers Administration Guide • March 2017
Содержание Netra SPARC S7-2 Series
Страница 1: ...SPARC and Netra SPARC S7 2 Series Servers Administration Guide Part No E73202 03 March 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 24: ...24 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 54: ...54 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 56: ...56 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 62: ...62 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 68: ...68 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 81: ...Display the Locator LED State of the Server Turn Off the Locator LED on page 80 Monitoring the Server 81 ...
Страница 82: ...82 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 86: ...86 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 90: ...90 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...